Stress analysis of a total hip acetabular component: an FEM study.

A stress analysis of a total hip acetabular component was performed using three-dimensional finite element modeling. The model consisted of 548 four-noded quadrilateral shell elements with 582 nodes. A worst-case support condition was assumed in which bony contact with small areas of the ilium, ischium, and pubis was represented by three-point support. Loads corresponding to the peak pressures developed in the hip when rising from a seated position--the activity contributing most to the fatigue of a prosthesis--were applied to the model. Peak stresses of 490 MPa are predicted around a screw hole in the region of greatest loading; according to the fatigue curve for porous-coated Ti-6Al-4V alloy, this translates into a component life of three years. When the area of bony support for the prosthesis is increased by a factor of 1.5, the fatigue life is more than doubled to seven years. The addition of restraints around the loaded hole to represent the placement of a screw extends the lifetime dramatically to 65 years. Substituting the material properties of cobalt-chromium alloy increases the predicted lifetime of the component to twelve years. We conclude that poor bone support can compromise the service life of titanium alloy acetabular components. Furthermore, we suggest that screw fixation be used to secure the prosthesis in the anterior-superior region if the prosthesis is not well supported by bone in the acetabulum.

[1]  Carter Dr Finite-element analysis of a metal-backed acetabular component. , 1983 .

[2]  D R Carter,et al.  Stress distributions in the acetabular region--II. Effects of cement thickness and metal backing of the total hip acetabular component. , 1982, Journal of biomechanics.

[3]  W. Harris Advances in total hip arthroplasty. The metal-backed acetabular component. , 1984, Clinical orthopaedics and related research.

[4]  H. Skinner,et al.  Fatigue properties of carbon- and porous-coated Ti-6Al-4V alloy. , 1984, Journal of biomedical materials research.

[5]  J. Davidson,et al.  The effect of HIPing on the fatigue and tensile strength of a case, porous-coated Co-Cr-Mo alloy. , 1986, Journal of biomedical materials research.

[6]  W. Harris A new total hip implant. , 1971, Clinical orthopaedics and related research.

[7]  Hwj Rik Huiskes,et al.  Finite element analysis of acetabular reconstruction. Noncemented threaded cups. , 1987, Acta orthopaedica Scandinavica.

[8]  D R Carter,et al.  Stress distributions in the acetabular region--I. Before and after total joint replacement. , 1982, Journal of biomechanics.

[9]  R. Crowninshield,et al.  Analytical support for acetabular component metal backing. , 1983, The Hip.

[10]  H Oonishi,et al.  Mechanical analysis of the human pelvis and its application to the artificial hip joint--by means of the three dimensional finite element method. , 1983, Journal of biomechanics.

[11]  W. A. Hodge,et al.  Contact pressures in the human hip joint measured in vivo. , 1986, Proceedings of the National Academy of Sciences of the United States of America.

[12]  H. Röhrle,et al.  Joint forces in the human pelvis-leg skeleton during walking. , 1984, Journal of biomechanics.

[13]  D R Pedersen,et al.  An axisymmetric model of acetabular components in total hip arthroplasty. , 1982, Journal of biomechanics.

[14]  T D Brown,et al.  In vitro contact stress distributions in the natural human hip. , 1983, Journal of biomechanics.