Axillary vein technique for pacemaker and implantable defibrillator leads implantation: a safe and alternative approach?

Different methods for venous access are used for permanent pacemaker or implantable cardioverter defibrillator (ICD), of which subclavian vein puncture technique is the most widely practised. Although this approach is relatively easy to learn, quick and offers high success rates, it may be associated with potential serious acute complications including pneumothorax, emopneumothorax, brachial plexus injury and longer-term complications such as lead fracture, loss of lead insulation and subclavian crush syndrome especially in young patients with ICD leads. Axillary vein approach seems to be a favourable technique not only for the prevention of acute complications but also to reduce lead failure including lead insulation and lead fracture prevention with a consequently better long-term lead survival compared with the classical subclavian approach. Although randomized studies are lacking, recent reports not only evaluated the safety and effectiveness of new fluoroscopic axillary venous puncture technique, but also compared it with the conventional intrathoracic subclavian venous puncture technique for the implantation of leads in permanent pacing. Various techniques of axillary vein puncture have been proposed ranging from a blind percutaneous puncture to the use of different tools such as contrast venography and ultrasound. In this article, we report a case of subclavian crush syndrome, the use of a modified Bellot's technique of axillary vein puncture that we currently use and the potential benefits of axillary vein puncture for pacemaker and ICD leads implantation compared with subclavian approach to avoid acute and long-term lead complications.

[1]  L. Paiva,et al.  Subclavian crush syndrome AND subcutaneous ICD in primary prevention patients. , 2017, Journal of cardiovascular medicine.

[2]  L. Ravà,et al.  Percutaneous Axillary Vein Approach in Pediatric Pacing: Comparison with Subclavian Vein Approach , 2013, Pacing and clinical electrophysiology : PACE.

[3]  B. He,et al.  A Comparison of Steep and Shallow Needle Trajectories in Blind Axillary Vein Puncture , 2013, Pacing and clinical electrophysiology : PACE.

[4]  D. Antonelli,et al.  Axillary Vein Puncture Without Contrast Venography for Pacemaker and Defibrillator Leads Implantation , 2013, Pacing and clinical electrophysiology : PACE.

[5]  D. Kim,et al.  LONG TERM EFFICACY OF AXILLARY VEIN APPROACH COMPARED WITH SUBCLAVIAN VEIN APPROACH FOR PERMANENT PACEMAKER IMPLANTATION , 2013 .

[6]  N. Naik,et al.  A comparison of lead placement through the subclavian vein technique with fluoroscopy-guided axillary vein technique for permanent pacemaker insertion. , 2012, The Canadian journal of cardiology.

[7]  A. Baranchuk,et al.  Subclavian crush syndrome: a cause of pacemaker lead fracture. , 2011, Cardiovascular journal of Africa.

[8]  M. Nobuyoshi,et al.  P2-11: Longterm lead survival after two types of venipuncture , 2006 .

[9]  P. Belott How to access the axillary vein. , 2006, Heart rhythm.

[10]  D. Shah,et al.  Prospective Study of Axillary Vein Puncture with or Without Contrast Venography for Pacemaker and Defibrillator Lead Implantation , 2005, Pacing and clinical electrophysiology : PACE.

[11]  J. Tharakan,et al.  Venogram-guided extrathoracic subclavian vein puncture. , 2003, Indian heart journal.

[12]  H. Halperin,et al.  Prospective Randomized Comparison of the Safety and Effectiveness of Placement of Endocardial Pacemaker and Defibrillator Leads Using the Extrathoracic Subclavian Vein Guided by Contrast Venography Versus the Cephalic Approach , 2001, Pacing and clinical electrophysiology : PACE.

[13]  A. Gardini,et al.  Blind Extrathoracic Subclavian Venipuncture for Pacemaker Implant: A 3‐Year Experience in 250 Patients , 1998, Pacing and clinical electrophysiology : PACE.

[14]  S. Furman,et al.  Insulation Lead Failure: Is it a Matter of Insulation Coating, Venous Approach, or Both? , 1998, Pacing and clinical electrophysiology : PACE.

[15]  A. Marshall,et al.  Evaluation of an Ultrasonically Guided Venepuncture Technique for the Placement of Permanent Pacing Electrodes , 1998, Pacing and clinical electrophysiology : PACE.

[16]  H. Calkins,et al.  Safety and effectiveness of placement of pacemaker and defibrillator leads in the axillary vein guided by contrast venography. , 1997, The American journal of cardiology.

[17]  S. Furman,et al.  Lead Fracture in Cephalic Versus Subclavian Approach with Transvenous Implantable Cardioverter Defibrillator Systems , 1996, Pacing and clinical electrophysiology : PACE.

[18]  J. Ball,et al.  Early complications of permanent pacemaker implantation: no difference between dual and single chamber systems. , 1995, British heart journal.

[19]  J. Ruskin,et al.  Subclavian Crush Syndrome Complicating Transvenous Cardioverter Defibrillator Systems , 1995, Pacing and clinical electrophysiology : PACE.

[20]  M. Petch,et al.  Early Complications After Dual Chamber Versus Single Chamber Pacemaker Implantation , 1994, Pacing and clinical electrophysiology : PACE.

[21]  D. Flynn,et al.  A New Approach to Percutaneous Subclavian Venipuncture to Avoid Lead Fracture or Central Venous Catheter Occlusion , 1993, Pacing and clinical electrophysiology : PACE.

[22]  C. Byrd Clinical Experience with the Extrathoracic Introducer Insertion Technique , 1993, Pacing and clinical electrophysiology : PACE.

[23]  S. Milstein,et al.  Anatomical Mechanisms Explaining Damage to Pacemaker Leads, Defibrillator Leads, and Failure of Central Venous Catheters Adjacent to the Sternoclavicular Joint , 1993, Pacing and clinical electrophysiology : PACE.

[24]  K. Tanaka,et al.  Long-term follow up of ventricular endocardial pacing leads. Complications, electrical performance, and longevity of 561 right ventricular leads. , 1993, Japanese heart journal.

[25]  E. Alt,et al.  Lead Fracture in Pacemaker Patients , 1987, The Thoracic and cardiovascular surgeon.

[26]  V. Parsonnet,et al.  Method for the rapid and atraumatic insertion of permanent endocardial pacemaker electrodes through the subclavian vein. , 1979, The American journal of cardiology.