Miniaturized luminescence lifetime-based oxygen sensor instrumentation utilizing a phase modulation technique

Optical oxygen sensors are mainly based on the principle of luminescence quenching. In contrast to already existing intensity-based systems, the measurement of the luminescence lifetime provides certain advantages, such as insensitivity to photobleaching or leaching of the dye or changes in the intensity of excitation light. This facilitates the use of simple optical systems or optical fibers. Phase measurement techniques have shown to be a powerful tool for indirect measurement of luminescence lifetimes. Here, dyes with luminescence decay times in the order of tens or hundreds of microseconds allow the use of simple opto-electronic circuitry and low-cost processing electronics. An optical oxygen sensor module has been developed with the dimensions of only 120 X 60 X 30 mm. The instrument is based on the measurement of the decay time of the luminophore by measuring the phase shift between the square-wave excitation and the detected square-wave of the emission coming from the sensor. The instrument is based on semiconductor devices (light-emitting diodes, photodiodes) and may be used for the detection of oxygen in gaseous or liquid samples. Platinum(II) octaethylporphyrin-ketone, which is incorporated in an oxygen-permeable polymer and which has an unquenched lifetime of approximately 60μs, is used as the oxygen-sensitive dye. The typical measurement range of the device is from 0 to 200 hPa oxygen partial pressure with a resolution of <I hPa over the whole measurement range. Measurement accuracy of <±1 hPa has been obtained for periods of 24 h of continuous measurement. The sensor response times t 90 are typically <1 s for gases and 1-5 min for liquid samples.

[1]  A. Schmillen Abklingzeitmessungen an flüssigen und festen Lösungen mit einem neuen Fluorometer , 1953 .

[2]  Otto S. Wolfbeis,et al.  Detection of fluorescence lifetime based on solid state technology and its application to optical oxygen sensing , 1995, Photonics West.

[3]  Max E. Lippitsch,et al.  Fibre-optic oxygen sensor with the fluorescence decay time as the information carrier , 1988 .

[4]  P. Hartmann,et al.  Effects of polymer matrices on calibration functions of luminescent oxygen sensors based on porphyrin ketone complexes. , 1996, Analytical chemistry.

[5]  Ingo Klimant,et al.  Recent progress in optical oxygen sensor instrumentation , 1995 .

[6]  Mauro Bacci,et al.  A new kind of oxygen-sensitive transducer based on an immobilized metallo-organic compound , 1993 .

[7]  Dmitri B. Papkovsky,et al.  New oxygen sensors and their application to biosensing , 1995 .

[8]  Gelii V. Ponomarev,et al.  Phosphorescent Complexes of Porphyrin Ketones: Optical Properties and Application to Oxygen Sensing , 1995 .

[9]  F. Duschinsky Eine allgemeine Theorie der zur Messung sehr kurzer Leuchtdauern dienenden Versuchsanordnungen (Fluorometer) , 1933 .

[10]  G. K. Rollefson,et al.  The Determination of the Fluorescence Lifetimes of Dissolved Substances by a Phase Shift Method , 1953 .

[11]  Govind Rao,et al.  Phase fluorometric sterilizable optical oxygen sensor , 1994, Biotechnology and bioengineering.

[12]  P. B. Arnoudse,et al.  Instrumentation for the breath-by-breath determination of oxygen and carbon dioxide based on nondispersive absorption measurements. , 1992, Analytical chemistry.

[13]  E. Gaviola Ein Fluorometer. Apparat zur Messung von Fluoreszenzabklingungszeiten , 1927 .

[14]  D. Lübbers,et al.  FLOX—an oxygen-flux-measuring system using a phase-modulation method to evaluate the oxygen-dependent fluorescence lifetime , 1995 .