In vivo assessment of a rotary left ventricular assist device-induced artificial pulse in the proximal and distal aorta.

The increasing clinical use of rotary left ventricular assist devices (LVADs) suggests that chronic attenuation of arterial pulse pressure has no clinically significant detrimental effects. However, it remains possible that modulating LVAD rotor speed to produce an artificial pulse may be of temporary or occasional benefit. We sought to evaluate a pulse produced by a continuous-flow, centrifugal pump in an ovine thoracic and abdominal aorta. Both ventricles of an adult sheep were resected to eliminate all native cardiac contributions to pulsatility, each replaced by a continuous-flow Thoratec HeartMate III blood pump (Burlington, MA, USA). An LVAD-induced pulsatile flow was achieved by sharply alternating the speed of the magnetically levitated rotor of the left pump between 1,500 rpm (artificial diastole) and 5,500 rpm (artificial systole) at a rate of 60 bpm at a "systolic" interval of 30%. A catheter was advanced from the ascending aorta to the iliac bifurcation via the ventricular assist device outflow graft for pressure measurement and data acquisition. The mean LVAD-induced pulse pressures were 34, 29, 27, and 26 mm Hg in the ascending, thoracic, and abdominal aorta, and the iliac bifurcation, respectively. The maximum rate of pressure rise (deltap/deltat) was between 189 and 238 mm Hg/s, approaching that of the native pulse, although the energy equivalent pressure did not exceed the mean arterial pressure. The HeartMate III's relatively stiff speed control, low rotor mass, and robust magnetic rotor suspension result in a responsive system, enabling very rapid speed changes that can be used to simulate physiologic pulse pressure and deltap/deltat.

[1]  P. Hornick,et al.  Pulsatile and nonpulsatile perfusion: the continuing controversy. , 1997, Journal of cardiothoracic and vascular anesthesia.

[2]  J. Grant,et al.  Comparative studies of pulsatile and nonpulsatile flow during cardiopulmonary bypass. II. The effects on adrenal secretion of cortisol. , 1978, The Journal of thoracic and cardiovascular surgery.

[3]  G. Jett Physiology of nonpulsatile circulation: acute versus chronic support. , 1999, ASAIO journal.

[4]  R B Shepard,et al.  Energy equivalent pressure. , 1966, Archives of surgery.

[5]  Satoshi Saito,et al.  End-organ function during chronic nonpulsatile circulation. , 2002, The Annals of thoracic surgery.

[6]  Daniel Tamez,et al.  Total Heart Replacement with Dual Centrifugal Ventricular Assist Devices , 2005, ASAIO journal.

[7]  Y Taenaka,et al.  Prolonged nonpulsatile left heart bypass with reduced systemic pulse pressure causes morphological changes in the aortic wall. , 1998, Artificial organs.

[8]  K. Sun,et al.  The Effects of Pulsatile Flow Upon Renal Tissue Perfusion During Cardiopulmonary Bypass: A Comparative Study of Pulsatile and Nonpulsatile Flow , 2005, ASAIO journal.

[9]  K. Litwak,et al.  HeartMate III: Pump Design for a Centrifugal LVAD with a Magnetically Levitated Rotor , 2001, ASAIO journal.

[10]  Y Taenaka,et al.  Diminished vasoconstrictive function caused by long-term nonpulsatile left heart bypass. , 1999, Artificial organs.

[11]  R. Deterling,et al.  The physiologic role of pulsatile and nonpulsatile blood flow. II. Effects on renal function. , 1967, Archives of surgery.

[12]  Akif Ündar,et al.  Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. , 2004 .

[13]  J F Antaki,et al.  Effect of pressure-flow relationship of centrifugal pump on in vivo hemodynamics: a consideration for design. , 1998, Artificial organs.

[14]  K. Taylor,et al.  Comparative studies of pulsatile and nonpulsatile flow during cardiopulmonary bypass. III. Response of anterior pituitary gland to thyrotropin-releasing hormone. , 1978, The Journal of thoracic and cardiovascular surgery.

[15]  John L. Myers,et al.  Precise Quantification of Pressure Flow Waveforms of a Pulsatile Ventricular Assist Device , 2005, ASAIO journal.

[16]  A Undar,et al.  Defining pulsatile perfusion: quantification in terms of energy equivalent pressure. , 1999, Artificial organs.

[17]  Y Sezai,et al.  Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation. , 1999, Artificial organs.

[18]  R. Deterling,et al.  Hemodynamic effects of pulsatile and nonpulsatile flow. , 1966, Archives of surgery.

[19]  R. J. Parsons,et al.  THE EFFECT OF THE PULSE ON THE SPREAD OF SUBSTANCES THROUGH TISSUES , 1938, The Journal of experimental medicine.

[20]  Biswajit Kar,et al.  First clinical use of the redesigned HeartMate II left ventricular assist system in the United States: a case report. , 2004, Texas Heart Institute journal.

[21]  G S Allen,et al.  The importance of pulsatile and nonpulsatile flow in the design of blood pumps. , 2008, Artificial organs.

[22]  W. Regelson,et al.  The physiolgic importance of pulsatile blood flow. , 1962, The New England journal of medicine.

[23]  Patrick Segers,et al.  Hemodynamic Modes of Ventricular Assist with a Rotary Blood Pump: Continuous, Pulsatile, and Failure , 2005, ASAIO journal.

[24]  O.H. Frazier,et al.  Use of the Flowmaker (Jarvik 2000) Left Ventricular Assist Device for Destination Therapy and Bridging to Transplantation , 2004, Cardiology.

[25]  P. Hickey,et al.  Pulsatile and nonpulsatile cardiopulmonary bypass: review of a counterproductive controversy. , 1983, The Annals of thoracic surgery.