Radiation protection in interventional radiology: survey results of attitudes and use.

PURPOSE To assess attitudes of interventional radiologists toward personal radiation protection and the use of radiation protection devices. MATERIALS AND METHODS Invitations to an anonymous online survey that comprised eight questions focused on operator attitudes toward radiation protection devices were sent via e-mail to the active membership of the Society of Interventional Radiology (SIR): a total of 3,158 e-mail invitations. A single reminder e-mail was sent. RESULTS There were 504 survey responders (16% response rate). Reported radiation safety device use included lead apron (99%), thyroid shield (94%), leaded eyeglasses (54%), ceiling-suspended leaded shield (44%), rolling leaded shields (12%), ceiling-suspended/rolling lead-equivalent apron (4%), radiation-attenuating sterile surgical gloves (1%), and sterile lead-equivalent patient-mounted drape (4%). Reasons commonly cited for not using certain devices were comfort (eyewear), ease of use (mounted shields), and lack of availability (rolling/hanging shields and patient-mounted shields). CONCLUSIONS Interventionalists have an array of tools from which to choose for personal radiation protection; however, for a variety of reasons related to lack of availability or choice, these tools are not universally employed. Further study may be of value to clarify why comfort was cited most often as the primary barrier to the use of protective eyewear and difficulty of use was cited as the primary barrier to use of mounted shields (despite reporting that concern for radiation-induced injury to the eye is paramount). It may also be of interest to further study why certain devices with demonstrable protection effects are not readily available, such as rolling/hanging and patient-mounted shields.

[1]  Alexander Norbash,et al.  Occupational health hazards in the interventional laboratory: time for a safer environment. , 2009, Journal of vascular and interventional radiology : JVIR.

[2]  Madan M Rehani,et al.  Radiation-associated lens opacities in catheterization personnel: results of a survey and direct assessments. , 2013, Journal of vascular and interventional radiology : JVIR.

[3]  T. Vrachliotis,et al.  Doses to operators during interventional radiology procedures: focus on eye lens and extremity dosimetry. , 2011, Radiation protection dosimetry.

[4]  Haraldur Bjarnason,et al.  An investigation of operator exposure in interventional radiology. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.

[5]  Heang-Ping Chan,et al.  Evaluation of the transmitted exposure through lead equivalent aprons used in a radiology department, including the contribution from backscatter. , 2003, Medical physics.

[6]  D. Back,et al.  Radiation protection for your hands. , 2005, Injury.

[7]  L. Wagner,et al.  Radiation-attenuating surgical gloves: effects of scatter and secondary electron production. , 1996, Radiology.

[8]  G. Sangiorgi,et al.  Reduction of scatter radiation during transradial percutaneous coronary angiography: A randomized trial using a lead‐free radiation shield , 2012, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[9]  Gabriel Bartal,et al.  Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology. , 2010, Journal of vascular and interventional radiology : JVIR.

[10]  D. Brenner,et al.  Cancer risks from diagnostic radiology. , 2008, The British journal of radiology.

[11]  Peter Ammann,et al.  Impact of a lead glass screen on scatter radiation to eyes and hands in interventional cardiologists , 2006, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[12]  F. Vanhavere,et al.  Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project. , 2011, Radiation protection dosimetry.

[13]  D. Kirsch,et al.  Comparison of a suspended radiation protection system versus standard lead apron for radiation exposure of a simulated interventionalist. , 2011, Journal of vascular and interventional radiology : JVIR.

[14]  S. Solomon,et al.  Comparing strategies for operator eye protection in the interventional radiology suite. , 2010, Journal of vascular and interventional radiology : JVIR.

[15]  E. Vañó,et al.  Eye lens exposure to radiation in interventional suites: caution is warranted. , 2008, Radiology.

[16]  Donald L. Miller,et al.  Occupational health hazards in the interventional laboratory: progress report of the Multispecialty Occupational Health Group. , 2010, Journal of Vascular and Interventional Radiology.

[17]  S. Walsh,et al.  Ionizing Radiation in Endovascular Interventions , 2008, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[18]  Z. Haskal Get protected: the eyes have it. , 2013, Journal of vascular and interventional radiology : JVIR.

[19]  C. Kelsey,et al.  Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists. , 2002, AJR. American journal of roentgenology.

[20]  Radiation safety during spine interventions. , 2005, Journal of vascular and interventional radiology : JVIR.

[21]  J. Thornton,et al.  Thyroid Dose During Neurointerventional Procedures: Does Lead Shielding Reduce the Dose? , 2007, CardioVascular and Interventional Radiology.

[22]  H. Meislin,et al.  A nine-year evaluation of emergency department personnel exposure to ionizing radiation. , 1985, Annals of Emergency Medicine.

[23]  Emily McFarlane,et al.  Conducting Survey Research among Physicians and other Medical Professionals - A Review of Current Literature , 2008 .