Measuring eyestrain from LCD TV according to adjustment factors of image

The evaluation of liquid crystal display (LCD) quality in terms of human factors shows more accurate results than conventional measurements such as image resolution and response speed. In this paper, we propose a new method for measuring eyestrain based on pupil accommodation speed according to the change of four adjustment factors -- brightness, contrast, saturation, and hue -- of images on an LCD TV. Experimental results showed that the order of affecting the eyestrain much was the changes of hue, brightness, contrast and saturation. Based on them, the solutions for suppressing eyestrain of watchers of LCD TV are discussed.

[1]  Kang Ryoung Park,et al.  Measuring the degree of eyestrain caused by watching LCD and PDP devices , 2009 .

[2]  A M Tai,et al.  Low-cost LCD spatial light modulator with high optical quality. , 1986, Applied optics.

[3]  Andry Rakotonirainy,et al.  Affordable visual driver monitoring system for fatigue and monotony , 2004, 2004 IEEE International Conference on Systems, Man and Cybernetics (IEEE Cat. No.04CH37583).

[4]  Edmond Sabo,et al.  Fractal analysis and recurrence quantification analysis of heart rate and pulse transit time for diagnosing chronic fatigue syndrome , 2002, Clinical Autonomic Research.

[5]  Kevin Arthur Effects of field of view on task performance with head-mounted displays , 1996, CHI Conference Companion.

[6]  Massoud Pedram,et al.  HEBS: histogram equalization for backlight scaling , 2005, Design, Automation and Test in Europe.

[7]  Humberto Remigio Gamba,et al.  Preliminary Evaluation of a SmartCam-based System for Real-Time Pupil Light Reflex Analysis , 2007 .

[8]  John Daugman How iris recognition works , 2004 .

[9]  B. Moser,et al.  The two-sample t test versus satterthwaite's approximate f test , 1989 .

[10]  Kenji Miyata,et al.  High performance low-temperature poly-Si n-channel TFTs for LCD , 1989 .

[11]  Homer H. Chen,et al.  Image Quality Enhancement for Low Backlight TFT-LCD Displays , 2007, 2007 IEEE International Conference on Image Processing.

[12]  G. Corrias,et al.  Psychological factors and visual fatigue in working with video display terminals , 2001, Occupational and environmental medicine.

[13]  Valery V. Tuchin,et al.  Estimation of melanin content in iris of human eye , 2005, SPIE BiOS.

[14]  John Daugman,et al.  New Methods in Iris Recognition , 2007, IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics).

[15]  B Gilmartin,et al.  The effect of Timolol Maleate on tonic accommodation, tonic vergence, and pupil diameter. , 1984, Investigative ophthalmology & visual science.