A Method for Assessing Ground-Truth Accuracy of the 5DCT Technique.

PURPOSE To develop a technique that assesses the accuracy of the breathing phase-specific volume image generation process by patient-specific breathing motion model using the original free-breathing computed tomographic (CT) scans as ground truths. METHODS Sixteen lung cancer patients underwent a previously published protocol in which 25 free-breathing fast helical CT scans were acquired with a simultaneous breathing surrogate. A patient-specific motion model was constructed based on the tissue displacements determined by a state-of-the-art deformable image registration. The first image was arbitrarily selected as the reference image. The motion model was used, along with the free-breathing phase information of the original 25 image datasets, to generate a set of deformation vector fields that mapped the reference image to the 24 nonreference images. The high-pitch helically acquired original scans served as ground truths because they captured the instantaneous tissue positions during free breathing. Image similarity between the simulated and the original scans was assessed using deformable registration that evaluated the pointwise discordance throughout the lungs. RESULTS Qualitative comparisons using image overlays showed excellent agreement between the simulated images and the original images. Even large 2-cm diaphragm displacements were very well modeled, as was sliding motion across the lung-chest wall boundary. The mean error across the patient cohort was 1.15 ± 0.37 mm, and the mean 95th percentile error was 2.47 ± 0.78 mm. CONCLUSION The proposed ground truth-based technique provided voxel-by-voxel accuracy analysis that could identify organ-specific or tumor-specific motion modeling errors for treatment planning. Despite a large variety of breathing patterns and lung deformations during the free-breathing scanning session, the 5-dimensionl CT technique was able to accurately reproduce the original helical CT scans, suggesting its applicability to a wide range of patients.

[1]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[2]  D. Yan,et al.  Respiratory motion sampling in 4DCT reconstruction for radiotherapy. , 2012, Medical physics.

[3]  Joachim Widder,et al.  Quality assurance of 4D-CT scan techniques in multicenter phase III trial of surgery versus stereotactic radiotherapy (radiosurgery or surgery for operable early stage (stage 1A) non-small-cell lung cancer [ROSEL] study). , 2011, International journal of radiation oncology, biology, physics.

[4]  Paul J Keall,et al.  Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients. , 2008, International journal of radiation oncology, biology, physics.

[5]  Steve B. Jiang,et al.  Effects of motion on the total dose distribution. , 2004, Seminars in radiation oncology.

[6]  P. Keall 4-dimensional computed tomography imaging and treatment planning. , 2004, Seminars in radiation oncology.

[7]  Michael Brady,et al.  MRF-Based Deformable Registration and Ventilation Estimation of Lung CT , 2013, IEEE Transactions on Medical Imaging.

[8]  David Thomas,et al.  A novel fast helical 4D-CT acquisition technique to generate low-noise sorting artifact-free images at user-selected breathing phases. , 2014, International journal of radiation oncology, biology, physics.

[9]  Suresh Senan,et al.  Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets. , 2005, International journal of radiation oncology, biology, physics.

[10]  M. Schell,et al.  Stereotactic body radiation therapy: the report of AAPM Task Group 101. , 2010, Medical physics.

[11]  J. McClelland,et al.  A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. , 2006, Medical physics.

[12]  Marjan A Admiraal,et al.  Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  J. Ehrhardt,et al.  An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing. , 2007, Medical physics.

[14]  H Handels,et al.  Motion Artifact Reducing Reconstruction of 4D CT Image Data for the Analysis of Respiratory Dynamics , 2007, Methods of Information in Medicine.

[15]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[16]  Michael Brady,et al.  MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration , 2012, Medical Image Anal..

[17]  Y. Mutaf,et al.  Optimization of internal margin to account for dosimetric effects of respiratory motion. , 2008, International journal of radiation oncology, biology, physics.

[18]  Jeffrey A. Fessler,et al.  ITERATIVE SORTING FOR 4DCT IMAGES BASED ON INTERNAL ANATOMY MOTION , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[19]  Maximilian Diehn,et al.  Reducing 4D CT artifacts using optimized sorting based on anatomic similarity. , 2011, Medical physics.

[20]  A. Hertanto,et al.  Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model. , 2012, Medical physics.

[21]  Lei Dong,et al.  Modeling respiratory motion for reducing motion artifacts in 4D CT images. , 2013, Medical physics.

[22]  Brian B. Avants,et al.  Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge , 2011, IEEE Transactions on Medical Imaging.

[23]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[24]  J. Dempsey,et al.  Novel breathing motion model for radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[25]  Benjamin M White,et al.  A novel CT acquisition and analysis technique for breathing motion modeling , 2013, Physics in medicine and biology.

[26]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[27]  Weiguo Lu,et al.  A simple fixed-point approach to invert a deformation field. , 2007, Medical physics.

[28]  Joe Y. Chang,et al.  The potential for dose escalation in lung cancer as a result of systematically reducing margins used to generate planning target volume. , 2006, International journal of radiation oncology, biology, physics.

[29]  Michael Brady,et al.  Globally Optimal Deformable Registration on a Minimum Spanning Tree Using Dense Displacement Sampling , 2012, MICCAI.

[30]  Michael Brady,et al.  Towards Realtime Multimodal Fusion for Image-Guided Interventions Using Self-similarities , 2013, MICCAI.

[31]  Tinsu Pan,et al.  Four-dimensional computed tomography: image formation and clinical protocol. , 2005, Medical physics.

[32]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[33]  Steve B. Jiang Radiotherapy of mobile tumors. , 2006, Seminars in radiation oncology.

[34]  P J Keall,et al.  Accuracy in the localization of thoracic and abdominal tumors using respiratory displacement, velocity, and phase. , 2009, Medical physics.