Parallel-connected converters for optimizing efficiency, reliability and grid harmonics in a wind turbine
暂无分享,去创建一个
The converter system for the Gamesa G10x 4.5 MW wind turbine consisting of 6 parallel-connected converters and some of the converter system control algorithms are presented. The benefits of this solution compared with a solution with only one converter are higher reliability, higher efficiency and possibility of extremely low grid harmonics.
[1] 何塞伊格纳西奥·略伦特冈萨雷斯,et al. Method for operation of a converter system , 2006 .