Cramér–Rao bounds for three‐point decomposition of water and fat

The noise analysis for three‐point decomposition of water and fat was extended to account for the uncertainty in the field map. This generalization leads to a nonlinear estimation problem. The Crámer–Rao bound (CRB) was used to study the variance of the estimates of the magnitude, phase, and field map by computing the maximum effective number of signals averaged (NSA) for any choice of echo time shifts. The analysis shows that the noise properties of the reconstructed magnitude, phase, and field map depend not only on the choice of echo time shifts but also on the amount of fat and water in each voxel and their alignment at the echo. The choice of echo time shifts for spin‐echo, spoiled gradient echo, and steady‐state free precession imaging techniques were optimized using the CRB. The noise analysis for the magnitude explains rough interfaces seen clinically in the boundary of fat and water with source images obtained symmetrically about the spin‐echo. It also provides a solution by choosing appropriate echo time shifts (−π/6 + πk, π/2 + πk, 7π/6 + πk), with k an integer. With this choice of echo time shifts it is possible to achieve the maximum NSA uniformly across all fat:water ratios. The optimization is also carried out for the estimation of phase and field map. These theoretical results were verified using Monte Carlo simulations with a newly developed nonlinear least‐squares reconstruction algorithm that achieves the CRB. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.

[1]  Harry L. Van Trees,et al.  Detection, Estimation, and Modulation Theory, Part I , 1968 .

[2]  Jean A. Tkach,et al.  Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon technique , 1995, Journal of magnetic resonance imaging : JMRI.

[3]  A. Macovski Noise in MRI , 1996, Magnetic resonance in medicine.

[4]  Q. Xiang,et al.  Water‐fat imaging with direct phase encoding , 1997, Journal of magnetic resonance imaging : JMRI.

[5]  K. Scheffler,et al.  Is TrueFISP a gradient‐echo or a spin‐echo sequence? , 2003, Magnetic resonance in medicine.

[6]  G. Gold,et al.  Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imaging , 2005, Magnetic resonance in medicine.

[7]  John M Pauly,et al.  Referenceless PRF shift thermometry , 2004, Magnetic resonance in medicine.

[8]  Jingfei Ma,et al.  Method for efficient fast spin echo Dixon imaging , 2002, Magnetic resonance in medicine.

[9]  L. Hall,et al.  Optimization of diffusion measurements using Cramer‐Rao lower bound theory and its application to articular cartilage , 2003, Magnetic resonance in medicine.

[10]  Michael Markl,et al.  Multicoil Dixon chemical species separation with an iterative least‐squares estimation method , 2004, Magnetic resonance in medicine.

[11]  G H Glover,et al.  Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction , 1991, Magnetic resonance in medicine.

[12]  Dwight G Nishimura,et al.  Fat‐suppressed steady‐state free precession imaging using phase detection , 2003, Magnetic resonance in medicine.

[13]  Q S Xiang,et al.  Chemical shift imaging with spectrum modeling , 2001, Magnetic resonance in medicine.

[14]  G. Glover Multipoint dixon technique for water and fat proton and susceptibility imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[15]  Audra E. Kosh,et al.  Linear Algebra and its Applications , 1992 .

[16]  J. Sijbers,et al.  Maximum likelihood estimation of signal amplitude and noise variance from MR data , 2004, Magnetic resonance in medicine.

[17]  Norbert J Pelc,et al.  Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation. , 2003, AJR. American journal of roentgenology.

[18]  Wilson Fong Handbook of MRI Pulse Sequences , 2005 .

[19]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[20]  Michael Markl,et al.  Cardiac CINE imaging with IDEAL water‐fat separation and steady‐state free precession , 2005, Journal of magnetic resonance imaging : JMRI.