GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy

GATE (Geant4 Application for Emission Tomography) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. Dedicated to the modelling of planar scintigraphy, single photon emission computed tomography (SPECT) and positron emission tomography (PET) acquisitions, this platform is widely used to assist PET and SPECT research. A recent extension of this platform, released by the OpenGATE collaboration as GATE V6, now also enables modelling of x-ray computed tomography and radiation therapy experiments. This paper presents an overview of the main additions and improvements implemented in GATE since the publication of the initial GATE paper (Jan et al 2004 Phys. Med. Biol. 49 4543-61). This includes new models available in GATE to simulate optical and hadronic processes, novelties in modelling tracer, organ or detector motion, new options for speeding up GATE simulations, examples illustrating the use of GATE V6 in radiotherapy applications and CT simulations, and preliminary results regarding the validation of GATE V6 for radiation therapy applications. Upon completion of extensive validation studies, GATE is expected to become a valuable tool for simulations involving both radiotherapy and imaging.

[1]  L Wang,et al.  MCML--Monte Carlo modeling of light transport in multi-layered tissues. , 1995, Computer methods and programs in biomedicine.

[2]  David Sarrut,et al.  Region-oriented CT image representation for reducing computing time of Monte Carlo simulations. , 2008, Medical physics.

[3]  Irène Buvat,et al.  GATE: Improving the computational efficiency , 2005 .

[4]  Ignace Lemahieu,et al.  Acceleration of GATE SPECT simulations , 2007 .

[5]  Lydia Maigne,et al.  Use of the GATE Monte Carlo package for dosimetry applications , 2006 .

[6]  Irène Buvat,et al.  Introducing improved voxel navigation and fictitious interaction tracking in GATE for enhanced efficiency. , 2009, Physics in medicine and biology.

[7]  Manuel Bardiès,et al.  Implementing dosimetry in GATE: dose-point kernel validation with GEANT4 4.8.1. , 2007, Cancer biotherapy & radiopharmaceuticals.

[8]  J Michael O'Connor,et al.  Characterization of scatter in cone-beam CT breast imaging: comparison of experimental measurements and Monte Carlo simulation. , 2009, Medical physics.

[9]  Maria Grazia Pia,et al.  GEANT4 low energy electromagnetic models for electrons and photons , 1999 .

[10]  W. Kalender,et al.  Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions , 2000 .

[11]  I Buvat,et al.  Validation of the Monte Carlo simulator GATE for indium-111 imaging , 2005, Physics in medicine and biology.

[12]  Peter R Seevinck,et al.  Factors affecting the sensitivity and detection limits of MRI, CT, and SPECT for multimodal diagnostic and therapeutic agents. , 2007, Anti-cancer agents in medicinal chemistry.

[13]  H Paganetti,et al.  Quantitative assessment of the physical potential of proton beam range verification with PET/CT , 2008, Physics in medicine and biology.

[14]  Arion F Chatziioannou,et al.  Monte Carlo simulations of absorbed dose in a mouse phantom from 18-fluorine compounds. , 2007, Medical physics.

[15]  Hiroshi Uchida,et al.  Dose-volume delivery guided proton therapy using beam on-line PET system. , 2006, Medical physics.

[16]  Nobuyuki Kanematsu,et al.  Biological dose calculation with Monte Carlo physics simulation for heavy-ion radiotherapy , 2006, Physics in medicine and biology.

[17]  H Thierens,et al.  Investigation of geometrical and scoring grid resolution for Monte Carlo dose calculations for IMRT , 2005, Physics in medicine and biology.

[18]  J F Ziegler,et al.  Comments on ICRU report no. 49: stopping powers and ranges for protons and alpha particles. , 1999, Radiation research.

[19]  Konstantina S. Nikita,et al.  Validation of a GATE model for the simulation of the Siemens biograph™ 6 PET scanner , 2007 .

[20]  C. Comtat,et al.  Monte Carlo Simulation for the ECAT EXACT HR+ system using GATE , 2003, IEEE Transactions on Nuclear Science.

[21]  Igor Mishustin,et al.  Neutrons from fragmentation of light nuclei in tissue-like media: a study with the GEANT4 toolkit. , 2005, Physics in medicine and biology.

[22]  Carole Lartizien,et al.  Incorporating Patient-Specific Variability in the Simulation of Realistic Whole-Body $^{18}{\hbox{F-FDG}}$ Distributions for Oncology Applications , 2009, Proceedings of the IEEE.

[23]  David Sarrut,et al.  Optimization of GEANT4 settings for Proton Pencil Beam Scanning simulations using GATE , 2010 .

[24]  L. Beaulieu,et al.  Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics. , 2004, Medical physics.

[25]  H Paganetti,et al.  Four-dimensional Monte Carlo simulation of time-dependent geometries , 2004, Physics in medicine and biology.

[26]  Luca Incrocci,et al.  Stereographic targeting in prostate radiotherapy: speed and precision by daily automatic positioning corrections using kilovoltage/megavoltage image pairs. , 2008, International journal of radiation oncology, biology, physics.

[27]  Eric C Frey,et al.  Development of a 4-D digital mouse phantom for molecular imaging research. , 2004, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.

[28]  Rick Best,et al.  Design and Construction , 2007 .

[29]  C. Moisan,et al.  A more physical approach to model the surface treatment of scintillation counters and its implementation into DETECT , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[30]  Martin Janecek,et al.  Simulating Scintillator Light Collection Using Measured Optical Reflectance , 2010, IEEE Transactions on Nuclear Science.

[31]  David Sarrut,et al.  Influence of Geant4 parameters on dose distribution and computation time for carbon ion therapy simulation. , 2010, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[32]  S. Nehmeh,et al.  Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners. , 2005, Medical physics.

[33]  E P Krenning,et al.  Peptide receptor imaging and therapy. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[34]  G. Santin,et al.  GATE: a Geant4-based simulation platform for PET and SPECT integrating movement and time management , 2003 .

[35]  Irène Buvat,et al.  Multidimensional B-spline parameterization of the detection probability of PET systems to improve the efficiency of Monte Carlo simulations. , 2010, Physics in medicine and biology.

[36]  D. Visvikis,et al.  RTNCAT (Real Time NCAT): Implementing Real Time physiological movement of voxellized phantoms in GATE , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[37]  Konstantina S. Nikita,et al.  Comparative evaluation of two commercial PET scanners, ECAT EXACT HR+ and Biograph 2, using GATE , 2006 .

[38]  Ignace Lemahieu,et al.  Monte Carlo simulations of a scintillation camera using GATE: validation and application modelling. , 2003, Physics in medicine and biology.

[39]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[40]  P. Lambin,et al.  A literature review of electronic portal imaging for radiotherapy dosimetry. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[41]  O Jäkel,et al.  Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization. , 2000, Physics in medicine and biology.

[42]  I. Chetty,et al.  Reporting and analyzing statistical uncertainties in Monte Carlo-based treatment planning. , 2006, International journal of radiation oncology, biology, physics.

[43]  Benjamin M. W. Tsui,et al.  Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms , 1999 .

[44]  J. Sempau,et al.  PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport , 2009 .

[45]  H Paganetti,et al.  Adaptation of GEANT4 to Monte Carlo dose calculations based on CT data. , 2004, Medical physics.

[46]  W. Enghardt,et al.  Direct time-of-flight for quantitative, real-time in-beam PET: a concept and feasibility study , 2007, Physics in medicine and biology.

[47]  Ge Wang,et al.  A mouse optical simulation environment (MOSE) to investigate bioluminescent phenomena in the living mouse with the Monte Carlo method. , 2004, Academic radiology.

[48]  Peter Bruyndonckx,et al.  Simulated performance of a small-animal PET scanner based on monolithic scintillation detectors , 2007 .

[49]  Radhe Mohan,et al.  Questions for comparison of clinical Monte Carlo codes , 2000 .

[50]  Dimitris Visvikis,et al.  Monte Carlo based performance assessment of different animal PET architectures using pixellated CZT detectors , 2006 .

[51]  Claude Comtat,et al.  Count rate performance study of the Lausanne ClearPET scanner demonstrator , 2007 .

[52]  I Buvat,et al.  Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging , 2004, Physics in medicine and biology.

[53]  M. Niclas,et al.  Design and construction of the ClearPET/XPAD small animal PET/CT scanner , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[54]  David Sarrut,et al.  Monte-Carlo based prediction of radiochromic film response for hadrontherapy dosimetry , 2009 .

[55]  Leticia Delgado Marín,et al.  Comparative antioxidant properties of some GABAergic phenols and related compounds, determined for homogeneous and membrane systems. , 2011, Medicinal chemistry (Shariqah (United Arab Emirates)).

[56]  H. Paganetti,et al.  Physics Settings for Using the Geant4 Toolkit in Proton Therapy , 2008, IEEE Transactions on Nuclear Science.

[57]  Rakesh Patel,et al.  Megavoltage computed tomography imaging: a potential tool to guide and improve the delivery of thoracic radiation therapy. , 2004, Clinical lung cancer.

[58]  Ignace Lemahieu,et al.  Cluster computing software for GATE simulations. , 2007, Medical physics.

[59]  David Sarrut,et al.  Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4 , 2011, Physics in medicine and biology.

[60]  J S Moore,et al.  Design and construction. , 1972, Hospitals.

[61]  T. Bortfeld,et al.  Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions. , 2000, Physics in medicine and biology.

[62]  Peter Bruyndonckx,et al.  Towards a continuous crystal APD-based PET detector design , 2007 .

[63]  Arion F. Chatziioannou,et al.  Compressed Voxels for High-Resolution Phantom Simulations in GATE , 2007, Molecular Imaging and Biology.

[64]  D. Boas,et al.  Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head. , 2002, Optics express.

[65]  I. Kawrakow,et al.  Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting. , 2004, Medical physics.

[66]  Jan-Jakob Sonke,et al.  Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. , 2009, International journal of radiation oncology, biology, physics.

[67]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[68]  P. Bruyndonckx,et al.  Using Cramer-Rao theory combined with Monte Carlo simulations for the optimization of monolithic scintillator PET detectors , 2006, IEEE Transactions on Nuclear Science.

[69]  Ellen Yorke,et al.  18F-FDG PET/CT for Image-Guided and Intensity-Modulated Radiotherapy* , 2009, Journal of Nuclear Medicine.

[70]  Katia Parodi,et al.  Comparison between in-beam and offline positron emission tomography imaging of proton and carbon ion therapeutic irradiation at synchrotron- and cyclotron-based facilities. , 2008, International journal of radiation oncology, biology, physics.

[71]  C. L. Le Rest,et al.  Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE , 2006, Physics in medicine and biology.

[72]  J. De Beenhouwer,et al.  Acceleration of GATE SPECT simulations , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[73]  T. Koi,et al.  Geometry and physics of the Geant4 toolkit for high and medium energy applications , 2009 .

[74]  E C Frey,et al.  Implementation of angular response function modeling in SPECT simulations with GATE , 2010, Physics in medicine and biology.

[75]  Hiroki Shirato,et al.  Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: a simulation study. , 2007, Medical physics.

[76]  F. Beekman,et al.  Optical simulation of monolithic scintillator detectors using GATE/GEANT4 , 2010, Physics in medicine and biology.

[77]  Lei Xing,et al.  Monte Carlo Dose Calculations for IMRT Head-and-Neck Patients With Dental Fillings Using the Phase Space Files for LINAC , 2012 .

[78]  L Maigne,et al.  Validation of a dose deposited by low-energy photons using GATE/GEANT4 , 2008, Physics in medicine and biology.

[79]  Igor Mishustin,et al.  Distributions of positron-emitting nuclei in proton and carbon-ion therapy studied with GEANT4. , 2006, Physics in medicine and biology.

[80]  Hugues Benoit-Cattin,et al.  Dynamic Partitioning of GATE Monte-Carlo Simulations on EGEE , 2010, Journal of Grid Computing.

[81]  C. Meessen,et al.  Simulation of PIXSCAN, a photon counting micro-CT for small animal imaging , 2009 .