THE RESIDUAL MONOMER IN DENTAL ACRYLIC RESIN AND ITS ADVERSE EFFECTS

Acrylic based resins are frequently used in daily dental practice. The most    common use of the materials includes denture bases and denture liners, temporary crowns and orthodontic appliances. In the mouth, properties and functional efficiency of applied acrylic resins depend on internal factors related to the methods and conditions of polymerization and on external factors that are related to the environment in which the material is placed. Residual monomer, which is released as a result of interaction of both sets of factors is often associated with irritation, inflammatory and allergic reactions of oral mucosa. The aim of this paper is to review literature dealing with the conditions of polymerization and biodegradation of acrylic resins under certain conditions in the oral cavity and their impact on oral health (reviewed literature available on Medline database during the past two decades.) Conclusion: Methods and conditions of acrylate polymerization, on the one hand, and properties of saliva, chewing and the presence of microorganisms in the oral cavity, on the other hand, can be considered responsible for the release of residual monomers. Clinically significant events followed by redness and erosion of the oral mucosa, burning sensation and burning mucosa and tongue, may be due to the effects of released, potentially cytotoxic, residual monomers.

[1]  A. Bettencourt,et al.  Evaluation of cytotoxicity and oxidative stress induced by acrylic bone cement in raw 264.7 macrophages , 2007 .

[2]  Martin Rosentritt,et al.  Acrylic removable appliances: comparative evaluation of different postpolymerization methods. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[3]  Ş. Canay,et al.  Effect of polymerization methods on the residual monomer level of acrylic resin denture base polymers , 2008 .

[4]  L. Menezes,et al.  Allergy to auto-polymerized acrylic resin in an orthodontic patient. , 2006, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[5]  J. L. Alessandrini,et al.  Effect of the curing conditions on the properties of an acrylic denture base resin microwave-polymerised. , 2003, Journal of dentistry.

[6]  J. Ferracane Hygroscopic and hydrolytic effects in dental polymer networks. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[7]  E. Aktas,et al.  Effect of post-polymerization heat-treatments on degree of conversion, leaching residual MMA and in vitro cytotoxicity of autopolymerizing acrylic repair resin. , 2011, Dental materials : official publication of the Academy of Dental Materials.

[8]  F. Huang,et al.  Cytotoxic effects of denture base materials on a permanent human oral epithelial cell line and on primary human oral fibroblasts in vitro. , 2001, The International journal of prosthodontics.

[9]  S. Yannikakis,et al.  A long term study on residual monomer release from denture materials. , 2008, The European journal of prosthodontics and restorative dentistry.

[10]  A. Harrison,et al.  Effect of the curing cycle on residual monomer levels of acrylic resin denture base polymers. , 1992, Journal of dentistry.

[11]  H. Tsuchiya,et al.  Leaching and cytotoxicity of formaldehyde and methyl methacrylate from acrylic resin denture base materials. , 1994, The Journal of prosthetic dentistry.

[12]  T. Lunder,et al.  Chronic urticaria from an acrylic dental prosthesis. , 2000, Contact Dermatitis.

[13]  Chang Yc,et al.  Cytotoxic effects of denture base materials on a permanent human oral epithelial cell line and on primary human oral fibroblasts in vitro. , 2001 .

[14]  Y. Lai,et al.  Influence of polymerization conditions on monomer elution and microhardness of autopolymerized polymethyl methacrylate resin. , 2002, European journal of oral sciences.

[15]  S. Ata,et al.  In vitro comparison of the cytotoxicity of acetal resin, heat-polymerized resin, and auto-polymerized resin as denture base materials. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[16]  R E Ogle,et al.  A new visible light-cured resin system applied to removable prosthodontics. , 1986, The Journal of prosthetic dentistry.

[17]  J. Santerre,et al.  Identifying enzyme activities within human saliva which are relevant to dental resin composite biodegradation. , 2005, Biomaterials.

[18]  G. Angelini,et al.  Labial edema due to an acrylic dental prosthesis , 2003, Contact dermatitis.

[19]  D van Steenberghe,et al.  The influence of surface free energy and surface roughness on early plaque formation. An in vivo study in man. , 1990, Journal of clinical periodontology.

[20]  J. McCabe,et al.  Influence of dietary simulating solvents on the viscoelasticity of temporary soft lining materials. , 2000, The Journal of prosthetic dentistry.

[21]  P Lambrechts,et al.  Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. , 1997, Dental materials : official publication of the Academy of Dental Materials.

[22]  S. Koka,et al.  Cytotoxicity of denture base resins. , 1997, The International journal of prosthodontics.

[23]  L. M. de Menezes,et al.  Residual monomer of autopolymerized acrylic resin according to different manipulation and polishing methods. An in situ evaluation. , 2008, The Angle orthodontist.

[24]  G. Caughman,et al.  Biocompatibility of visible light-polymerized denture base resins. , 1993, The International journal of prosthodontics.

[25]  M. Wilson,et al.  The effects of surface roughness and type of denture acrylic on biofilm formation by Streptococcus oralis in a constant depth film fermentor , 2001, Journal of applied microbiology.

[26]  S. Freeman,et al.  Allergic contact stomatitis caused by acrylic monomer in a denture , 2001, The Australasian journal of dermatology.

[27]  M. Okazaki,et al.  Leachability of plasticizer and residual monomer from commercial temporary restorative resins. , 2004, Journal of dentistry.

[28]  U. Kedjarune,et al.  Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer. , 1999, Australian dental journal.

[29]  N. Sarkar,et al.  Degree of conversion in denture base materials for varied polymerization techniques. , 2000, Journal of oral rehabilitation.

[30]  J. Santerre,et al.  Salivary Esterase Activity and Its Association with the Biodegradation of Dental Composites , 2004, Journal of dental research.

[31]  A. Bettencourt,et al.  Biodegradation of acrylic based resins: A review. , 2010, Dental materials : official publication of the Academy of Dental Materials.

[32]  D. Morton,et al.  Release of dibenzoyl peroxide from polymethyl methacrylate denture base resins: an in vitro evaluation. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[33]  G. Caughman,et al.  Effects of denture base resins on oral epithelial cells. , 1991, The International journal of prosthodontics.

[34]  R. D. de Souza,et al.  Cytotoxicity of denture base and hard chairside reline materials: a systematic review. , 2012, The Journal of prosthetic dentistry.

[35]  C. Vergani,et al.  Cytotoxicity of denture base acrylic resins: a literature review. , 2003, The Journal of prosthetic dentistry.

[36]  P. Vallittu,et al.  Effect of polymerization temperature and time on the residual monomer content of denture base polymers. , 1998, European journal of oral sciences.

[37]  V. Blagojevic,et al.  Microwave polymerization of denture base materials. A comparative study. , 1999, Journal of oral rehabilitation.

[38]  B. Willershausen,et al.  The influence of oral bacteria on the surfaces of resin-based dental restorative materials--an in vitro study. , 1999, International dental journal.

[39]  E. Aktas,et al.  Effect of leaching residual methyl methacrylate concentrations on in vitro cytotoxicity of heat polymerized denture base acrylic resin processed with different polymerization cycles , 2011, Journal of applied oral science : revista FOB.

[40]  M. Quirynen,et al.  The influence of surface free energy and surface roughness on early plaque formation.: An in vivo study in man , 1992 .

[41]  K. Knoernschild,et al.  Relationships between denture base resin cytotoxicity and cell lipid metabolism. , 1995, The International journal of prosthodontics.

[42]  Y. Uresin,et al.  Influence of polymerization method, curing process, and length of time of storage in water on the residual methyl methacrylate content in dental acrylic resins. , 2006, Journal of biomedical materials research. Part B, Applied biomaterials.

[43]  J. Drummond,et al.  Degradation, Fatigue, and Failure of Resin Dental Composite Materials , 2008, Journal of dental research.

[44]  L. Longman,et al.  Orofacial reaction to methacrylates in dental materials: a clinical report. , 2003, The Journal of prosthetic dentistry.

[45]  J. Santerre,et al.  Relation of dental composite formulations to their degradation and the release of hydrolyzed polymeric-resin-derived products. , 2001, Critical reviews in oral biology and medicine : an official publication of the American Association of Oral Biologists.