Specimen recentrifugation and elevated troponin I levels.
暂无分享,去创建一个
[1] S. Vasikaran,et al. Outliers affecting cardiac troponin I measurement: comparison of a new high sensitivity assay with a contemporary assay on the Abbott ARCHITECT analyser , 2014, Annals of clinical biochemistry.
[2] Xiaoming Wang,et al. Rapid identification of falsely elevated serum cardiac troponin I values in a stat laboratory. , 2014, Laboratory medicine.
[3] Mario J. Garcia,et al. ACCF 2012 expert consensus document on practical clinical considerations in the interpretation of troponin elevations: a report of the American College of Cardiology Foundation task force on Clinical Expert Consensus Documents. , 2012, Journal of the American College of Cardiology.
[4] H. Sadrzadeh,et al. The effect of recentrifugation of serum separator tubes on concentration of serum analytes. , 2012, Annals of clinical and laboratory science.
[5] Frederick G. Strathmann,et al. Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays. , 2011, American journal of clinical pathology.
[6] G. Dimeski. Evidence on the cause of false positive troponin I results with the Beckman AccuTnI method , 2011, Clinical chemistry and laboratory medicine.
[7] P. O’Rourke,et al. Outliers as a cause of false cardiac troponin results: investigating the robustness of 4 contemporary assays. , 2011, Clinical chemistry.
[8] L. Bilić-Zulle,et al. Comparison of methods: Passing and Bablok regression. , 2011, Biochemia medica.
[9] P. O’Rourke,et al. Falsely elevated troponin I results due to outliers indicate a lack of analytical robustness , 2010, Annals of clinical biochemistry.
[10] Fred S Apple,et al. A new season for cardiac troponin assays: it's time to keep a scorecard. , 2009, Clinical chemistry.
[11] G. Lum,et al. False Positive Cardiac Troponin Results in Patients Without Acute Myocardial Infarction , 2006 .
[12] Y. Jong,et al. Falsely elevated troponin I attributed to inadequate centrifugation using the Access® immunoassay analyzer , 2006, Clinical chemistry and laboratory medicine.
[13] S. Fleming,et al. False-positive cardiac troponin I in a routine clinical population. , 2002, The American journal of cardiology.
[14] T. Fukui,et al. Pseudonormokalaemia caused by recentrifugation of blood samples after storage in gel-separator tubes , 2001, Annals of clinical biochemistry.
[15] M. Vidaud,et al. Comparison of single and repeat centrifugation of blood specimens collected in BD evacuated blood collection tubes containing a clot activator for cardiac troponin I assay on the ACCESS analyzer. , 2000, Clinical chemistry.
[16] T. Fukui,et al. High serum potassium concentrations after recentrifugation of stored blood specimens. , 2000, The New England journal of medicine.
[17] L. Voipio‐Pulkki,et al. Degradation of cardiac troponin I: implication for reliable immunodetection. , 1998, Clinical chemistry.
[18] F. Apple,et al. Prevention of analytical false-positive increases of cardiac troponin I on the Stratus II analyzer. , 1997, Clinical chemistry.
[19] A. Pfäfflin. Doubt on prevention of false-positive results of cardiac troponin I by recentrifugation , 2009, Clinical chemistry and laboratory medicine.
[20] W. Bablok,et al. A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part I , 1983, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie.