Analysis of the Effect of Packing Materials (Fills) and Flow Rate on the Range and Efficiency of a Forced Draft Evaporative Cooling Tower

In the present study, experimental investigation is carried out on two different kinds of packing materials (fills). PVC fills that are traditionally used in the industry are compared and analyzed against the cellulose-based paper fills. Different mass flow rates of air are used to study the effect of the flow rate of air on the forced draft cooling tower. The volume flow rate of water also varied, and the range of the cooling tower, along with efficiency, was analyzed. Along with these two parameters, the effect of inlet water temperature on the performance of the tower was studied. Cooling tower efficiency was plotted against different L/G ratios ranging from 0.95 to 7.67. Results showed that the type of packing has a significant impact on the cooling tower performance. Paper fills gave a maximum cooling tower efficiency and range equal to 93.12% and 16.5 °C, respectively. The optimal L/G ratio range of 0.96 to 1.44 was identified as the point at which the cooling tower demonstrated its highest performance. The effect of the mass flow rate of water on the performance of the tower was far greater compared to the volume flow rate of water and inlet water temperature. The paper fills are found to be most effective under current experimental conditions, and the same can be implemented in the industrial towers under a wide spectrum of inlet water temperatures, mass flow rates of air, and volume flow rates of water.

[1]  M. Lucas,et al.  Effect of fill length and distribution on the thermal performance of an inverted cooling tower , 2023, Applied Thermal Engineering.

[2]  N. Gulhane,et al.  Experimental study on the performance of wet cooling towers using different packing materials , 2022, Materials Today: Proceedings.

[3]  M. Kanniche,et al.  Experimental Characterization of Liquid Flows in Cooling Tower Packing , 2022, Industrial & Engineering Chemistry Research.

[4]  H. Panchal,et al.  Experimental investigations on indirect contact type liquid desiccant cooling systems for high latent heat load application , 2022, Case Studies in Thermal Engineering.

[5]  A. Tejero‐González,et al.  Optimal operation of evaporative cooling pads: A review , 2021, Renewable and Sustainable Energy Reviews.

[6]  Zainab T. Al-Sharify,et al.  Performance of a Cooling Tower with the Use of a New Kind of High-density Polyethylene (HDPE) Packing , 2021, Journal of Engineering Research.

[7]  Shiva Kumar,et al.  Experimental investigation on use of alternative innovative materials for sustainable cooling applications , 2021 .

[8]  Prabhu Appavu,et al.  Assessment on effectiveness of a shower type cooling tower , 2021 .

[9]  K. Raahemifar,et al.  Experimental Investigation on Improvement of Wet Cooling Tower Efficiency with Diverse Packing Compaction Using ANN-PSO Algorithm , 2020, Energies.

[10]  X. Y. Zhao,et al.  Experimental study on the heat and mass transfer characteristics of a counter-flow wet cooling tower with foam ceramic packing , 2019, Thermophysics and Aeromechanics.

[11]  Pei Wang,et al.  Experimental investigation of the heat and mass transfer phenomena in a counterflow wet cooling tower with foam ceramic packing , 2018 .

[12]  M. Rahmati,et al.  Investigation of heat transfer in mechanical draft wet cooling towers using infrared thermal images: An experimental study. , 2017 .

[13]  K. Sudhakar,et al.  Experimental performance of a direct evaporative cooler in composite climate of India , 2017 .

[14]  Guanhong Zhang,et al.  Selection of wetted media for pre-cooling of air entering natural draft dry cooling towers , 2017 .

[15]  Javier Ruiz Ramírez,et al.  Optimum Design and Operation of an HVAC Cooling Tower for Energy and Water Conservation , 2017 .

[16]  A. Sedaghat,et al.  Experimental study on improving operating conditions of wet cooling towers using various rib numbers of packing , 2016 .

[17]  Ranjan Das,et al.  Tower characteristics correlation and parameter retrieval in wet-cooling tower with expanded wire mesh packing , 2016 .

[18]  Ming Gao,et al.  Influence of non-uniform layout fillings on thermal performance for wet cooling tower , 2016 .

[19]  A. Ragupathy,et al.  Optimization of cooling tower performance with different types of packings using Taguchi approach , 2015 .

[20]  Ingo Jahn,et al.  Influence of ambient conditions and water flow on the performance of pre-cooled natural draft dry cooling towers , 2014 .

[21]  Mohammad Layeghi,et al.  Investigating the performance of cellulosic evaporative cooling pads , 2011 .

[22]  M. Boumaza,et al.  Experimental investigation of the performance characteristics of a counterflow wet cooling tower , 2010 .

[23]  Farhad Gharagheizi,et al.  Experimental study on the performance of mechanical cooling tower with two types of film packing , 2007 .