Effect of cerumen on infrared ear temperature measurement.

This pilot study examined whether the occlusion of one ear canal with cerumen affected the usual temperature difference between the ears as measured with an infrared thermometer. Ear-based temperature measurements were made in 14 elderly nursing home residents before and 3 to 4 days after irrigation to clear cerumen from the occluded ear. The presence of cerumen tended to lower the temperature reading, with a mean change of -0.24 +/- 0.47 degrees F (-0.13 +/- 0.47 degrees C, p = 0.08) and individual differences ranging from -0.9 to 0.4 degrees F (-0.5 to 0.2 degrees C), 43% of subjects (6/14) had values lower by -0.5 degrees F (-0.3 degrees C) or more. The advantage of removing impacted cerumen before making infrared ear temperature measurements may be offset by the time and inconvenience of the irrigation procedure. Improved hearing may be a more important outcome of cerumen removal, with secondary benefit for temperature measurement.

[1]  Erickson Rs,et al.  ACCURACY OF INFRARED EAR THERMOMETRY AND TRADITIONAL TEMPERATURE METHODS IN YOUNG CHILDREN , 1994 .

[2]  R. Erickson,et al.  Accuracy of infrared ear thermometry and other temperature methods in adults. , 1994, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[3]  R S Erickson,et al.  Comparison of ear‐based, bladder, oral, and axillary methods for core temperature measurement , 1993, Critical care medicine.

[4]  S. King,et al.  Cerumen-impaction management for clients of all ages. , 1993, The Nurse practitioner.

[5]  T. Terndrup An appraisal of temperature assessment by infrared emission detection tympanic thermometry. , 1992, Annals of emergency medicine.

[6]  T. Terndrup,et al.  Impact of operator technique and device on infrared emission detection tympanic thermometry. , 1992, The Journal of emergency medicine.

[7]  J. Nobel Infrared ear thermometry. , 1992, Health devices.

[8]  D. Nierman,et al.  Core temperature measurement in the intensive care unit , 1991, Critical care medicine.

[9]  S. VanderBrug Medendorp,et al.  Tympanic Membrane Temperatures Compared to Rectal and Oral Temperatures , 1991 .

[10]  S. Pransky The impact of technique and conditions of the tympanic membrane upon infrared tympanic thermometry. , 1991, Clinical pediatrics.

[11]  P. Roberson,et al.  Infrared, thermistor, and glass-mercury thermometry for measurement of body temperature in children with cancer. , 1991, Clinical pediatrics.

[12]  J. Chamberlain,et al.  Comparison of a Tympanic Thermometer to Rectal and Oral Thermometers in a Pediatric Emergency Department , 1991, Clinical pediatrics.

[13]  R. Erickson,et al.  Comparison of Tympanic and Oral Temperatures In Surgical Patients , 1991, Nursing research.

[14]  P. Roland,et al.  Catastrophic otologic injury from oral jet irrigation of the external auditory canal , 1991, The Laryngoscope.

[15]  J. Fortenberry,et al.  Evaluation of an infrared tympanic membrane thermometer in pediatric patients. , 1990, Pediatrics.

[16]  J. Janken,et al.  Effect of cerumen removal on the hearing ability of geriatric patients. , 1990, Journal of advanced nursing.

[17]  D. Danzl,et al.  Infrared tympanic thermography in the emergency department. , 1989, The Journal of emergency medicine.

[18]  T. Terndrup,et al.  A comparison of oral, rectal, and tympanic membrane-derived temperature changes after ingestion of liquids and smoking. , 1989, The American journal of emergency medicine.

[19]  F. Perkins,et al.  Infrared tympanic thermometer: evaluation of a new clinical thermometer. , 1988, Critical care medicine.

[20]  D. Mahoney One simple solution to hearing impairment. , 1987, Geriatric nursing.

[21]  C. Blodgett,et al.  Incidence of occlusion due to impacted cerumen among mentally retarded adolescents. , 1986, American journal of mental deficiency.

[22]  W. Meyerhoff,et al.  Otologic manifestations of aging. , 1982, Otolaryngologic clinics of North America.

[23]  J. Greenleaf,et al.  External auditory canal temperature as an estimate of core temperature. , 1972, Journal of applied physiology.

[24]  W. I. Cranston,et al.  TEMPERATURE IN THE EXTERNAL AUDITORY MEATUS AS AN INDEX OF CENTRAL TEMPERATURE CHANGES. , 1964, Journal of applied physiology.