Current Sheets Equivalent to End-Winding Currents of Turbine-Generator Stator and Rotor
暂无分享,去创建一个
The steady-state end-winding current distribution of turbine generators is replaced by appropriate current sheets of the sinusoidal type. By assuming that the end-winding coils of stator and rotor close through the air gap, their respective current distributions are represented by systems of closed currents. Then, the total current distributions for stator and rotor are each separated into four components; peripheral, axial, and radial current sheet, and return current.
[1] R. T. Smith. End Component of Armature Leakage Reactance of Round-Rotor Generators , 1958, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.
[2] G. W. Staats,et al. Eddy Currents in the End Portion of Turbine-Generator Stator Windings , 1957, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.