Overview of the RF source development programme at IPP Garching

The development of a large-area RF source for negative hydrogen ions, an official EFDA task agreement, is aiming at demonstrating ITER-relevant ion source parameters. This implies a current density of 200?A?m?2 accelerated D? ions at a source filling pressure of ?0.3?Pa and an electron-to-ion ratio of ?1 from an extraction area similar to the positive-ion based sources at JET and ASDEX Upgrade and for pulse lengths of up to 1?h. The work is progressing along three lines in parallel: (i) optimization of current densities at low pressure and electron/ion ratio, utilizing small extraction areas (<0.01?m2) and short pulses (<6?s), in this parameter range the ITER requirements are met or even exceeded; (ii) investigation on extended extraction areas (<0.03?m2) and pulse lengths of up to 3600?s and (iii) investigation of a size-scaling on a half-size ITER plasma source. Three different test beds are being used to carry out these investigations in parallel. An extensive diagnostic and modelling programme accompanies the activities. The paper discusses the recent achievements and the status in these three areas of development.

[1]  Kazuhiro Watanabe,et al.  Development of negative ion sources for the ITER neutral beam injector , 2001 .

[2]  M. Bandyopadhyay Studies of an inductively coupled negative hydrogen ion radio frequency source through simulations and experiments , 2004 .

[3]  J. Paméla The physics of production, acceleration and neutralization of large negative ion beams , 1995 .

[4]  Th. Franke,et al.  Status and plans for the development of a RF negative ion source for ITER NBI , 2005 .

[5]  Keishi Sakamoto,et al.  R&D on a high energy accelerator and a large negative ion source for ITER , 2005 .

[6]  A. Hatayama,et al.  Numerical analysis of the spatial nonuniformity in a Cs-seeded H - ion source , 2006 .

[7]  B. Heinemann,et al.  Progress in the development of a large RF negative ion source for fusion , 2001 .

[8]  Kazuhiro Watanabe,et al.  A 14 cm×36 cm volume negative ion source producing multi‐ampere H− ion beams , 1990 .

[9]  F. Rau,et al.  Stellarators - Report on the Ninth International Workshop on Stellarators, held at the Max-Planck-Institut für Plasmaphysik, Garching, Germany, 10 - 14 May 1993 , 1994 .

[10]  B. Beaumont,et al.  Commissioning and Performance of the New ASDEX Upgrade Neutral Beam Injector , 1998 .

[11]  D. Riz,et al.  Negative ion sources for neutral beam injection into fusion machines , 1998 .

[12]  A. Krylov,et al.  Experimental results from the Cadarache 1 MV test bed with SINGAP accelerators , 2006 .

[13]  B. Heinemann,et al.  Diagnostics of the cesium amount in an RF negative ion source and the correlation with the extracted current density , 2005 .

[14]  B. Zaniol,et al.  Caesium and tungsten behaviour in the filamented arc driven Kamaboko-III negative ion source , 2006 .

[15]  M. Bacal,et al.  Basic processes of negative hydrogen ion production and destruction in sources and beams (invited) , 1996 .

[16]  Nbi-team,et al.  Development of Powerful RF Plasma Sources for Present and Future NBI Systems , 2004 .

[17]  A. Tanga,et al.  Measurement of ion flow in a negative ion source using a Mach probe , 2004 .

[18]  B. Heinemann,et al.  Recent developments of long pulse RF ion sources for NBI systems , 2001 .

[19]  U. Fantz,et al.  Spectroscopy—a powerful diagnostic tool in source development , 2006 .

[20]  T. Franke,et al.  RF-source development for ITER: Large area H− beam extraction, modifications for long pulse operation and design of a half size ITER source , 2005 .

[21]  D. Post,et al.  High current source of He− ions , 1980 .

[22]  B. Beaumont,et al.  Large-Area, High-Transparency Extraction System for Negative Ions , 1998 .

[23]  P. Zaccaria,et al.  Design of cryosorption pumps for TEST BEDS of ITER relevant Neutral Beam Injectors , 2005 .

[24]  W. S. Cooper,et al.  Comparison of H− and D− production in a magnetically filtered multicusp source , 1990 .

[25]  K. Usui,et al.  Improvement of beam performance in the negative-ion based NBI system for JT-60U , 2003 .

[26]  Kazuhiro Watanabe,et al.  Cesium mixing in the multi‐ampere volume H− ion source , 2008 .

[27]  B. Heinemann,et al.  Development of a RF source for ITER NBI: First results with D− operation , 2005 .