Fetal cardiac electromechanical intervals during labour and effects of hypoxia and cord compression

Summary. Cardiac electromechanical intervals were measured during labour in 103 unselected human fetuses. Mean values (±SD) for the three intervals measured were 76.01±9.93 ms for the pre‐ejection period, 41.56±8.51 ms for the isovolumetric contraction time and 156.23±16.58 ms for the left ventricular ejection time. These are consistent with previously reported data from our own and other centres. The intervals studied did not alter significantly as labour proceeded or during uterine contractions. There was no consistent correlation between them and fetal scalp blood P o2,P co2 or pH, although the pre‐ejection period was shortened considerably in three very acidaemic or hypoxic fetuses, and it was prolonged in association with tight nuchal cord entanglement and variable decelerations in fetal heart rate. These findings raise the possibility of using recorded cardiac electromechanical intervals to determine the clinical significance of different fetal heart‐rate patterns that suggest the possibility of fetal distress.

[1]  Y Murata,et al.  Antepartum evaluation of the pre-ejection period of the fetal cardiac cycle. , 1978, American journal of obstetrics and gynecology.

[2]  C. Martin,et al.  Cardiac systolic time intervals in fetal monkeys: pre-ejection period. , 1978, American journal of obstetrics and gynecology.

[3]  J. Fleming,et al.  FETAL ELECTROMECHANICAL INTERVALS IN LABOUR , 1978, British journal of obstetrics and gynaecology.

[4]  I. H. Rowe,et al.  The pre-ejection period of the fetal heart: patterns of change during labor. , 1974, American journal of obstetrics and gynecology.

[5]  Y Murata,et al.  Systolic Time Intervals of the Fetal Cardiac Cycle , 1974, Postgraduate medicine.

[6]  J. P. Rasmussen,et al.  Influence of Transient Hypoxia and Reoxygenation on the Pre‐Ejection Period of the Heart , 1974, Acta anaesthesiologica Scandinavica.

[7]  I. H. Rowe,et al.  The pre-ejection period of the fetal heart: detection during labor with Doppler ultrasound. , 1973, American journal of obstetrics and gynecology.

[8]  J. W. Goodwin,et al.  The pre-ejection period of the fetal heart: response to stress in the term fetal lamb. , 1973, American journal of obstetrics and gynecology.

[9]  E. Hon Electronic evaluation of the fetal heart rate. VI. Fetal distress-a working hypothesis. , 1962, American journal of obstetrics and gynecology.

[10]  村田 雄二 Cardiac systolic time intervals in fetal monkeys : pre-ejection period , 1981 .

[11]  J. Claeys,et al.  Characteristic changes of the pre-ejection period of the human fetal heart during umbilical cord complications , 1980, Journal of perinatal medicine.

[12]  J Morgenstern,et al.  Systolic time intervals of the fetal cardiac cycle. , 1978, Journal of perinatal medicine.