Measurement of electric-field intensities using scanning near-field microwave microscopy

In this paper, we propose methods for the measurement of electric intensities of a microwave field above the surface of microwave circuits. Using miniaturized coaxial antennas, we measure all spatial components of the induced field above device-under-test. A special position/signal difference method is used to better localize the measured field and increase the spatial resolution of the field mapping. During the scanning process, the antenna is driven at the defined distance above the sample surface according to previously acquired topographic data. For measurement of the tangential-field components parallel to the sample surface, the antenna is tilted by approximately 45/spl deg/ relative to the sample surface. By its rotation about the vertical axis, various components of the field are measured, and vertical and horizontal electric-field intensities are recalculated. The probes are calibrated in a well-defined field standard and allow good quantitative characterization of the measured field.

[1]  Koji Mizuno,et al.  Scanning near-field millimeter-wave microscopy using a metal slit as a scanning probe , 2001 .

[2]  Gabriel M. Rebeiz,et al.  Near electric field mapping above X-Band MMICs using modulated scattering , 1996, 1996 IEEE MTT-S International Microwave Symposium Digest.

[3]  F. C. Wellstood,et al.  Imaging microwave electric fields using a near-field scanning microwave microscope , 1998 .

[4]  Gabriel M. Rebeiz,et al.  Near-field Mapping above a Coupled-line Filter and a MMIC , 1998 .

[5]  K. Karrai,et al.  Piezoelectric tip‐sample distance control for near field optical microscopes , 1995 .

[6]  Michael Golosovsky,et al.  A millimeter-wave near-field scanning probe with an optical distance control , 1998 .

[7]  Linda P. B. Katehi,et al.  Active-amplifier-array diagnostics using high-resolution electrooptic field mapping , 2001 .

[8]  Theodor W. Hänsch,et al.  Scanning electromagnetic transmission line microscope with sub-wavelength resolution , 1989 .

[9]  R. Luebbers,et al.  FDTD calculation of radiation patterns, impedance, and gain for a monopole antenna on a conducting box , 1992 .

[10]  Gang Liu,et al.  A quasistatic FDTD source model for coaxially driven monopole antennas , 2000 .

[11]  Roman Kantor,et al.  Method for increasing sensitivity of shear-force distance control for scanning near-field microscopy , 1999 .

[12]  A. Lauer,et al.  Calibration of electric coaxial near-field probes and applications , 1998 .

[13]  A. L. Cullen,et al.  Electric Probe Measurements on Microstrip , 1980 .