DC fault protection structures at a DC-link node in a radial multi-terminal high-voltage direct current system

In a multi-terminal HVDC system, DC circuit breakers (DCCBs) are conventionally connected in a star-configuration to enable isolation of a DC fault from the healthy system parts. However, a star-connection of DCCBs has disadvantages in terms of loss, capacity, reliability, etc. By rearranging the star-connection DCCBs, a novel delta-configuration of DCCBs is proposed in this paper. As each terminal is connected to each of the other terminals through only one DCCB, the current flows through only one DCCB when transferring power between any two terminals compared with two DCCBs in the current path for the conventional star-arrangement. The total loss of the proposed delta-configuration is only 33.3% of that of star-configuration, yielding a high efficiency. Also, any DC fault current is shared between two DCCBs instead of one DCCB in the faulty branch suffering the fault current. As a result, DCCB capacities in the proposed delta-configuration are only half those in a star-arrangement. Additionally, in the case of one or two DCCBs out of order, the power can still be transferred among three or two terminals, thereby affording high supply security of all HVDC links. Based on the DCCB delta-configuration, two novel DC fault protection structures with external and internal DC inductances are proposed. Their characteristics are discussed and it is shown a DC fault can be isolated using slow DCCBs without exposing any converter to significant over-current. The results demonstrate DC fault tolerant operation is achieved by using the proposed DC fault protection structures with delta-configuration.

[1]  Jae-Do Park,et al.  DC Ring-Bus Microgrid Fault Protection and Identification of Fault Location , 2013, IEEE Transactions on Power Delivery.

[2]  Pavol Bauer,et al.  A Novel Distributed Direct-Voltage Control Strategy for Grid Integration of Offshore Wind Energy Systems Through MTDC Network , 2013, IEEE Transactions on Industrial Electronics.

[3]  Foster F. Dai,et al.  Impact of Transceiver RFIC Impairments on MIMO System Performance , 2012, IEEE Transactions on Industrial Electronics.

[4]  Sumaira Tasnim,et al.  Power losses from wind generated electricity in high voltage AC transmission: an analysis through simulation , 2014 .

[5]  Jean Mahseredjian,et al.  Detailed and Averaged Models for a 401-Level MMC–HVDC System , 2012 .

[6]  Rong Zeng,et al.  Design and Operation of a Hybrid Modular Multilevel Converter , 2015, IEEE Transactions on Power Electronics.

[7]  Derrick Holliday,et al.  Quasi Two-Level Operation of Modular Multilevel Converter for Use in a High-Power DC Transformer With DC Fault Isolation Capability , 2015, IEEE Transactions on Power Electronics.

[8]  John E. Fletcher,et al.  A Hybrid Modular Multilevel Converter With Novel Three-Level Cells for DC Fault Blocking Capability , 2015, IEEE Transactions on Power Delivery.

[9]  Z. John Shen,et al.  Wide-Bandgap Solid-State Circuit Breakers for DC Power Systems: Device and Circuit Considerations , 2015, IEEE Transactions on Electron Devices.

[10]  Masahiro Takasaki,et al.  A Surgeless Solid-State DC Circuit Breaker for Voltage-Source-Converter-Based HVDC Systems , 2014, IEEE Transactions on Industry Applications.

[11]  G. B. Gharehpetian,et al.  Improving Fault Ride-Through Capability of Fixed-Speed Wind Turbine by Using Bridge-Type Fault Current Limiter , 2013, IEEE Transactions on Energy Conversion.

[12]  Boon-Teck Ooi,et al.  Locating and Isolating DC Faults in Multi-Terminal DC Systems , 2007, IEEE Transactions on Power Delivery.

[13]  Z. Shi,et al.  Design and numerical investigation of A HVDC vacuum switch based on artificial current zero , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  J. Jatskevich,et al.  Dynamic Averaged and Simplified Models for MMC-Based HVDC Transmission Systems , 2013, IEEE Transactions on Power Delivery.

[15]  Dragan Jovcic,et al.  Evaluation of Semiconductor Based Methods for Fault Isolation on High Voltage DC Grids , 2013, IEEE Transactions on Smart Grid.

[16]  Lambros Ekonomou,et al.  Comparison of metal-oxide surge arresters circuit models and implementation on high-voltage transmission lines of the Hellenic network , 2010 .

[17]  Pavol Bauer,et al.  Impact of HVDC transmission system topology on multiterminal DC network faults , 2015, 2015 IEEE Power & Energy Society General Meeting.

[18]  Lars Liljestrand,et al.  Separation of the Energy Absorption and Overvoltage Protection in Solid-State Breakers by the Use of Parallel Varistors , 2014, IEEE Transactions on Power Electronics.