Optimized Ultra‐Fast Imaging Sequence (OUFIS)

The DUFIS sequence can make ultra‐fast images (˜10 ms) without the use of rapidly switched gradients. The RF excitation sequence is spatially selective so that only a small fraction of the magnetization in each imaging pixel is used which produces a poor imaging signal to noise ratio (SNR). We have developed several alternative RF sequences that use RF pulses with multiple phases, and also with just 0° and 180° phases to excite almost all the magnetization in a pixel and greatly improve the SNR. The optimization of these pulse sequences (now called OUFIS) have been conducted both analytically and by numerical searches, with various linear and nonlinear models. Both theoretical and computational methods used in the optimizations are described in detail. Preliminary experimental results are briefly presented with several possible applications of the OUFIS excitation sequences suggested.

[1]  Matthew O'Donnell,et al.  Optimization of two-dimensional spatially selective NMR pulses by simulated annealing , 1988 .

[2]  Richard R. Ernst,et al.  Diffusion and field‐gradient effects in NMR Fourier spectroscopy , 1974 .

[3]  J H Duyn,et al.  Fast volume scanning with frequency‐shifted burst MRI , 1994, Magnetic resonance in medicine.

[4]  E. T. Jaynes,et al.  MATRIX TREATMENT OF NUCLEAR INDUCTION , 1955 .

[5]  C. D. Gelatt,et al.  Optimization by Simulated Annealing , 1983, Science.

[6]  Ray Freeman,et al.  Band-selective radiofrequency pulses , 1991 .

[7]  R. L. Garwin,et al.  Spin Echo Serial Storage Memory , 1955 .

[8]  N. Metropolis,et al.  Equation of State Calculations by Fast Computing Machines , 1953, Resonance.

[9]  Meir Shinnar,et al.  The synthesis of soft pulses with a specified frequency response , 1989, Magnetic resonance in medicine.

[10]  T. Carpenter,et al.  Design and application of prefocused pulses by simulated annealing , 1990 .

[11]  C. Counsell PREVIEW: a new ultrafast imaging sequence requiring minimal gradient switching. , 1993, Magnetic resonance imaging.

[12]  M Deimling,et al.  Ultra‐Rapid Gradient Echo Imaging , 1995, Magnetic resonance in medicine.

[13]  C. Beaulieu,et al.  Reduction of ringing and blurring artifacts in fast spin‐echo imaging , 1993, Journal of magnetic resonance imaging : JMRI.

[14]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[15]  W Huk,et al.  QUEST ‐ a quick echo split nmr imaging technique , 1993, Magnetic resonance in medicine.

[16]  R. E. Wysong,et al.  DANTE Ultrafast Imaging Sequence (DUFIS) , 1993 .