Three-phase short circuit synchronous machines-V

This paper is the fifth of a series which the authors have presented on the subject of synchronous machines. Part I was an extension of the fundamental theory; Part II, a treatment of torque-angle characteristics under steady-state conditions; Part III, a study of torque-angle characteristics under transient conditions; and Part IV, an analysis of single-phase short circuits. In the present paper, equations for the currents in the armature phases and field under three-phase short circuit are developed. The analysis is divided into three parts. The first covers the case of short circuit at no-load when the resistance is negligible in determining the magnitude of the current although it must naturally be considered in finding the decrement factors; the second considers the same case where the resistance does affect the magnitude of the current; the third covers the case of short circuit under load when resistance is negligible as in the first case. The effect of the nature of the load, i. e., whether the power factor is lagging or leading, is studied and some interesting results are brought out. It is shown that short circuits under load may give less current than at no-load, and it is further developed that under certain practical operating conditions it is even possible to obtain sub-stantially no fundamental current. The paper is illustrated with comparisons of calculated curves and oscillograms showing the actual currents obtained in test.

[1]  N. S. Diamant Calculation of Sudden Short-Circuit Phenomena of Alternators , 1915, Transactions of the American Institute of Electrical Engineers.

[2]  Ludwig Dreyfus,et al.  Ausgleichvorgänge beim plötzlichen Kurzschluß von Synchrongeneratoren , 1916 .

[3]  R. E. Doherty,et al.  Reactance of Synchronous Machines and its Applications , 1918, Transactions of the American Institute of Electrical Engineers.

[4]  R. E. Doherty,et al.  Short-circuit current of induction motors and generators , 1921, Journal of the American Institute of Electrical Engineers.

[5]  R. E. Doherty A simplified method of analyzing short-circuit problems , 1923, Journal of the American Institute of Electrical Engineers.

[6]  W. Lyon Transient conditions in electric machinery , 1923, Journal of the American Institute of Electrical Engineers.

[7]  C. M. Laffoon Short-Circuits of A-C. Generators-II , 1924, Transactions of the American Institute of Electrical Engineers.

[8]  Laffoon Short circuits of alternating-current generators , 1924, Journal of the A.I.E.E..

[9]  R. F. Franklin Short-circuit currents of synchronous machines , 1925, Journal of the A.I.E.E..

[10]  Vladimir Karapetoff,et al.  Initial and Sustained Short-Circuits in Synchronous Machines Analytical and Graphical Treatment of General Cases of Armature Windings Displaced by Arbitrary Angles, with Applications to One-, Two- and Three-Phase Machines , 1925, Transactions of the American Institute of Electrical Engineers.

[11]  Karapetoff Variable armature leakage reactance in salient-pole synchronous machines , 1926, Journal of the A.I.E.E..

[12]  R. E. Doherty,et al.  Synchronous Machines-III Torque-Angle Characteristics Under Transient Conditions , 1927, Transactions of the American Institute of Electrical Engineers.

[13]  R. H. Park Two Reaction Theory of Synchronous Machines , 1929 .

[14]  Yu H. Ku Transient analysis of A-C. machinery — II , 1932, Electrical Engineering.