Morphometric X-ray Absorptiometry and Morphometric Radiography of the Spine: A Comparison of Analysis Precision in Normal and Osteoporotic Subjects

Abstract: Morphometric techniques, which use conventional lateral spine radiographs to quantify vertebral body shape (morphometric radiography, MRX), have proved a useful tool in the identification and evaluation of osteoporotic vertebral deformities. Recently a new method of acquiring the images required for vertebral morphometry using dual-energy X-ray absorptiometry scanners (morphometric X-ray absorptiometry, MXA) has been developed. In this study we compare repeat analysis precision of vertebral height measurement using MXA and MRX. Twenty-four postmenopausal women were recruited (mean age 67 + 5.8 years): 12 normal subjects and 12 with osteoporosis and vertebral deformities. Each subject had a MXA scan and lateral thoracic and lumbar radiographs at a single appointment, which were each analyzed quantitatively in a masked fashion, using a standard 6-point method, twice by one observer and once by a second observer. Anterior (Ha), mid (Hm) and posterior (Hp) vertebral heights were measured and wedge (Ha/Hp) and mid-wedge (Hm/Hp) ratios calculated for each vertebral body. Intra- and interobserver precision were consistently poorer in MXA compared with MRX in both normal subjects and those with vertebral deformities, with MXA CV% generally at least 50% higher than corresponding values for MRX. For both MXA and MRX interobserver precision was clearly poorer than intraobserver precision, a problem associated with any morphometric technique. MXA intra- and interobserver precision were significantly poorer for subjects with vertebral deformities compared with those without, with a CV% for deformity subjects up to twice that of normal subjects. Conversely, MRX showed little or no obvious worsening of intra- or interobserver precision for deformity subjects. Comparison of MXA precision in the normal and deformed vertebrae of the deformity subjects demonstrated that the poorer precision in these subjects compared with normal subjects was the result of increased variability in point placement on the deformed vertebrae themselves. However, the precision for normal vertebrae in these subjects was also somewhat poorer than the precision in normal subjects. We conclude that MXA precision is generally poorer than that of MRX and that the presence of vertebral deformities has a more pronounced effect on MXA precision than on MRX precision.

[1]  C. Cooper,et al.  Epidemiology of osteoporosis. , 2002, Best practice & research. Clinical rheumatology.

[2]  S. Cummings,et al.  A new approach to defining normal vertebral dimensions , 1991, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[3]  B E NORDIN,et al.  The radiological diagnosis of osteoporosis: a new approach. , 1960, Clinical radiology.

[4]  M. Kleerekoper,et al.  Reversal of vertebral deformities in osteoporosis: Measurement error or “rebound”? , 1994, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[5]  S. H. Kan,et al.  Epidemiology of vertebral fractures in women. , 1989, American journal of epidemiology.

[6]  T. Spector,et al.  Prevalence of vertebral fracture in women and the relationship with bone density and symptoms: The chingford study , 1993, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[7]  M. Nevitt,et al.  Vertebral fracture assessment using a semiquantitative technique , 1993, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[8]  G. Blake,et al.  Vertebral morphometry studies using dual-energy x-ray absorptiometry. , 1997, Seminars in nuclear medicine.

[9]  D. Kiel Assessing vertebral fractures. National Osteoporosis Foundation Working Group on Vertebral Fractures. , 1995, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[10]  M. Dougados,et al.  Clinical evaluation of spine morphometric X-ray absorptiometry. , 1998, British journal of rheumatology.

[11]  S. Cummings,et al.  Randomised trial of effect of alendronate on risk of fracture in women with existing vertebral fractures , 1996, The Lancet.

[12]  C. Cooper,et al.  Vertebral fractures [8] , 1992 .

[13]  R. Ziegler,et al.  A newly developed spine deformity index (SDI) to quantitate vertebral crush fractures in patients with osteoporosis. , 1988, Bone and mineral.

[14]  S. Cummings,et al.  Risk factors for hip fracture in white women. Study of Osteoporotic Fractures Research Group. , 1995, The New England journal of medicine.

[15]  D W Hukins,et al.  Comparison of the precision of two vertebral morphometry programs for the lunar EXPERT-XL imaging densitometer. , 1998, The British journal of radiology.

[16]  R. Epstein,et al.  Pre-existing fractures and bone mass predict vertebral fracture incidence in women. , 1991, Annals of internal medicine.

[17]  A. Silman,et al.  Mortality Associated with Vertebral Deformity in Men and Women: Results from the European Prospective Osteoporosis Study (EPOS) , 1998, Osteoporosis International.

[18]  S. Cummings,et al.  A comparison of morphometric definitions of vertebral fracture , 1991, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[19]  H. Genant,et al.  A Preliminary Evaluation of the Lunar Expert‐XL for Bone Densitometry and Vertebral Morphometry , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[20]  C. Cooper,et al.  Population-based study of survival after osteoporotic fractures. , 1993, American journal of epidemiology.

[21]  L M Hurxthal,et al.  Measurement of anterior vertebral compressions and biconcave vertebrae. , 1968, The American journal of roentgenology, radium therapy, and nuclear medicine.

[22]  P. Nicholson,et al.  Vertebral morphometry in women aged 50-81 years. , 1993, Bone and Mineral.

[23]  A. Silman,et al.  The prevalence of vertebral deformity in European men and women: The european vertebral osteoporosis study , 1996, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[24]  J. Kanis,et al.  Epidemiology of osteoporosis. , 1992, Bone.

[25]  Richard Eastell,et al.  Erratum: 1991 Classification of vertebral fractures (J Bone Miner Res 6:207-215) , 1991 .

[26]  G. Blake,et al.  Patient dose in morphometric X-ray absorptiometry. , 1995, Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA.

[27]  KjeldKürstein Jensen,et al.  A SIMPLE X-RAY METHOD FOR MONITORING PROGRESS OF OSTEOPOROSIS , 1981, The Lancet.

[28]  S. Cummings,et al.  Lifetime risks of hip, Colles', or vertebral fracture and coronary heart disease among white postmenopausal women. , 1989, Archives of internal medicine.