Amorphous silicon pixel layers with cesium iodide converters for medical radiography

We describe the properties of evaporated layers of cesium iodide (thallium activated) deposited on substrates that enable easy coupling to amorphous silicon pixel arrays. The CsI(Tl) layers range in thickness from 65 to 220 /spl mu/m. We used the two-boat evaporator system to deposit CsI(Tl) layers. This system ensures the formation of the scintillator film with homogenous thallium concentration which is essential for optimizing the scintillation light emission efficiency. The Tl concentration was kept to 0.1-0.2 mole percent for the highest light output. Temperature annealing can affect the microstructure as well as light output of the CsI(Tl) film. 200-360/spl deg/C temperature annealing can increase the light output by a factor of two. The amorphous silicon pixel arrays are p-i-n diodes approximately 1 /spl mu/m thick with transparent electrodes to enable them to detect the scintillation light produced by X-rays incident on the CsI(Tl). Digital radiography requires a good spatial resolution. This is accomplished by making the detector pixel size less than 50 /spl mu/m. The light emission from the CsI(Tl) is collimated by techniques involving the deposition process on patterned substrates. We have measured MTF of greater than 12 line pairs per mm at the 10% level. >

[1]  J. A. Kierstead,et al.  Radiation damage in undoped CsI and CsI(Tl) , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[2]  J. A. Shepherd,et al.  Performance and fabrication of thin film NaI(Tl) scintillators for use on imaging photomultiplier tubes , 1992 .

[3]  N. Horwitz,et al.  Readout techniques and radiation damage of undoped cesium iodide , 1990 .

[4]  Koichiro Oba,et al.  CsI(Na) Scintillation Plate with High Spatial Resolution , 1987, IEEE Transactions on Nuclear Science.

[5]  Victor Perez-Mendez,et al.  Amorphous silicon based radiation detectors , 1991 .

[6]  K. Wittenburg,et al.  Radiation damage of CsI(Tl) crystals in a long term exposure at PETRA , 1985 .

[7]  Victor Perez-Mendez,et al.  Signal readout in a-Si:H pixel detectors , 1992 .

[8]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[9]  E. Kuper,et al.  Peculiarities of CCD and photodiode arrays application to X-ray image detection , 1991 .

[10]  Victor Perez-Mendez,et al.  X-ray and charged particle detection with CsI(Tl) layer coupled to a Si:H photodiode layers , 1991 .

[11]  Walter Dr. Hillen,et al.  Signal-to-noise performance in cesium iodide x-ray fluorescent screens , 1991, Medical Imaging.

[12]  M. Riebesell,et al.  Radiation damage of BGO and CsI(Tl) crystals , 1985 .

[13]  R. Pehl,et al.  Trace element determination with semiconductor detector x-ray spectrometers , 1973 .

[14]  H. Moser,et al.  Properties of CsI(TI) — Renaissance of an old scintillation material , 1985 .

[15]  R. Kamermans,et al.  Scintillation characteristics of pure and Tl-doped CsI crystals , 1990 .

[16]  G. Mageras,et al.  A measurement of the light yield of common inorganic scintillators , 1988 .

[18]  Masaaki Kobayashi,et al.  Radiation damage of CsI(Tl) crystals above 103 rad , 1987 .

[19]  Calvin E. Moss,et al.  Temperature dependence of CsI (T1) absolute scintillation yield , 1993, IEEE Transactions on Nuclear Science.

[20]  R. Street,et al.  AMORPHOUS-SILICON PIXEL ARRAYS , 1991 .

[21]  William W. Moses,et al.  Design of a pulsed X-ray system for fluorescent lifetime measurements with a timing accuracy of 109 ps , 1992 .

[22]  J. B. Birks,et al.  The Theory and Practice of Scintillation Counting , 1965 .