Single-phase ac–dc–ac topology for grid overvoltage and voltage harmonic mitigation

A single-phase ac–dc–ac topology to improve power quality is proposed in this study. This configuration is obtained from the addition of a floating capacitor H-bridge converter on the grid side of the conventional ac–dc–ac three-leg topology. The role of the structure is not only to ensure regulated load voltage with fixed amplitude and frequency, grid current with low harmonic content and unitary power factor, but also to mitigate fundamental overvoltage and voltage harmonics at the grid. As a consequence, the proposed topology is suitable to operate as unified power quality compensator or uninterrupted power supply. It does not use isolation transformer and is capable of generating multilevel input voltages due to the cascaded H-bridge. The operation with asymmetrical dc-link voltages is considered to increase the number of voltage levels and reduce the harmonic content of the generated input voltages. Two pulse-width modulation techniques and a control system are developed to regulate the dc-link voltages and to decrease the harmonic distortion (HD), lowering the switching stress and also the power losses. The proposed configuration is compared with the conventional one with respect to HD and semiconductor losses. Simulated and experimental results are presented for validation purposes.

[1]  Ahmed Al-Durra,et al.  $LCL$ Filter Design and Performance Analysis for Grid-Interconnected Systems , 2014, IEEE Transactions on Industry Applications.

[2]  Germano Lambert-Torres,et al.  Smart Impedance: A New Way to Look at Hybrid Filters , 2016, IEEE Transactions on Smart Grid.

[3]  Jonathan K. H. Shek,et al.  Filter Design for Cable Overvoltage and Power Loss Minimization in a Tidal Energy System With Onshore Converters , 2016, IEEE Transactions on Sustainable Energy.

[4]  Pablo Lezana,et al.  Cascaded Multilevel Inverter With Regeneration Capability and Reduced Number of Switches , 2008, IEEE Transactions on Industrial Electronics.

[5]  Montie Alves Vitorino,et al.  Investigation of Three-Phase AC–DC–AC Multilevel Nine-Leg Converter , 2016, IEEE Transactions on Industry Applications.

[6]  Yeliz Yoldas,et al.  Mitigation of power quality problems using distribution static synchronous compensator: a comprehensive review , 2015 .

[7]  R. Sheba Rani,et al.  Analysis of active power filter for harmonic mitigation in distribution system , 2016, 2016 International Conference on Electrical, Electronics, and Optimization Techniques (ICEEOT).

[8]  Jaime A. Rohten,et al.  Discrete Nonlinear Control based on a double dq Transform of a Multi-Cell UPQC , 2011, IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society.

[9]  C. B. Jacobina,et al.  AC-DC-AC multilevel converters based on three-leg converters , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[10]  Frede Blaabjerg,et al.  Modulation Schemes With Enhanced Switch Thermal Distribution for Single-Phase AC–DC–AC Reduced-Switch Converters , 2016, IEEE Transactions on Power Electronics.

[11]  A. Bento,et al.  Integrated one-cycle control for three-leg universal active power filter , 2008, 2008 IEEE Power Electronics Specialists Conference.

[12]  Yasmeena,et al.  A review of UPQC topologies for reduced DC link voltage with MATLAB simulation models , 2016, 2016 International Conference on Emerging Trends in Engineering, Technology and Science (ICETETS).

[13]  Michael A. E. Andersen,et al.  Evolution of Very High Frequency Power Supplies , 2014, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[14]  H. van der Broeck,et al.  Analysis and Realization of a Pulse Width Modulator Based on Voltage Space Vectors , 1986, 1986 Annual Meeting Industry Applications Society.

[15]  Nady Rocha,et al.  Flexible Series/Parallel AC–DC–AC Motor Drive System , 2015, IEEE Transactions on Industry Applications.

[16]  Cursino B. Jacobina,et al.  AC-DC-AC six-phase machine drive system based on single-phase bridge converters , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[17]  Cursino B. Jacobina,et al.  Fault tolerant ac-dc-ac single-phase to three-phase converter , 2011 .

[18]  Miguel Rodriguez,et al.  Simplified Voltage-Sag Filler for Line-Interactive Uninterruptible Power Supplies , 2008, IEEE Transactions on Industrial Electronics.

[19]  Quoc-Nam Trinh,et al.  An Advanced Current Control Strategy for Three-Phase Shunt Active Power Filters , 2013, IEEE Trans. Ind. Electron..

[20]  Cursino B. Jacobina,et al.  Single-Phase AC-DC-AC Multilevel Five-leg Converter Based on a High-Frequency Transformer , 2014, 2021 IEEE Energy Conversion Congress and Exposition (ECCE).

[21]  Hurng-Liahng Jou,et al.  Three-Arm AC Automatic Voltage Regulator , 2011, IEEE Transactions on Industrial Electronics.

[22]  Dushan Boroyevich,et al.  Advances in Power Conversion and Drives for Shipboard Systems , 2015, Proceedings of the IEEE.

[23]  Thomas A. Lipo,et al.  Adjustable-speed drive with single-phase induction machine for HVAC applications , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[24]  Lei Hu,et al.  Reconfiguration of Carrier-Based Modulation Strategy for Fault Tolerant Multilevel Inverters , 2007, IEEE Transactions on Power Electronics.

[25]  Xu Lie,et al.  A transformerless cascaded AC-DC-AC converter for multiphase propulsion drive application , 2011, 2011 International Conference on Electrical Machines and Systems.

[26]  C.B. Jacobina,et al.  Application of single-phase to three-phase converter motor drive systems with IGBT dual module losses reduction , 2009, 2009 Brazilian Power Electronics Conference.

[27]  Jung-Min Kwon,et al.  High-performance online UPS using three-leg-type converter , 2005, IEEE Trans. Ind. Electron..

[28]  Johann W. Kolar,et al.  Review of Three-Phase PWM AC–AC Converter Topologies , 2011, IEEE Transactions on Industrial Electronics.

[29]  Frede Blaabjerg,et al.  Line-to-line voltage based modulation scheme for single-phase reduced switch ac-dc-ac converters to achieve improved performance , 2015, 2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia).

[30]  Math Bollen,et al.  Active harmonic filters: Control techniques review , 2016, 2016 17th International Conference on Harmonics and Quality of Power (ICHQP).

[31]  Jung-Min Kwon,et al.  High-Performance Transformerless Online UPS , 2008, IEEE Transactions on Industrial Electronics.

[32]  Marian P. Kazmierkowski,et al.  Control of Three-Level PWM Converter Applied to Variable-Speed-Type Turbines , 2009, IEEE Transactions on Industrial Electronics.

[33]  Bhim Singh,et al.  Power quality improvement using optimized Passive Filter for 12-pulse rectifier-chopper in LCI fed synchronous motor drives , 2011, 2011 World Congress on Information and Communication Technologies.

[34]  A. M. Hava,et al.  A DC bus capacitor design method for various inverter applications , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[35]  Frede Blaabjerg,et al.  Adaptive SVM to compensate DC-link voltage ripple for four-switch three-phase voltage-source inverters , 1999 .

[36]  Joan Rocabert,et al.  Multilevel Diode-Clamped Converter for Photovoltaic Generators With Independent Voltage Control of Each Solar Array , 2008, IEEE Transactions on Industrial Electronics.