From chip to cooling tower data center modeling: Part II Influence of chip temperature control philosophy

The chiller cooled data center environment consists of many interlinked elements that are usually treated as individual components. This chain of components and their influences on each other must be considered in determining the benefits of any data center design and operational strategies seeking to improve efficiency, such as temperature control fan algorithms. Using the models developed in part I of this work, this paper extends the analysis to include the electronics within the rack through considering the processor heat sink temperature. This has allowed determination of the influence of various cooling strategies on the data center coefficient of performance. The strategy of increasing inlet aisle temperature is examined in some detail and found not to be a robust methodology for improving the overall energy performance of the data center, while tight temperature controls at the chip level consistently provides better performance, yielding more computing per watt of cooling power. These findings are of strong practical relevance for the design of fan control algorithms at the rack level and general operational strategies in data centers. Finally, the impact of heat sink thermal resistance is considered and the potential data center efficiency gains from improved heat sink designs are discussed.

[1]  Patrick A. Walsh,et al.  A Novel Approach to Low Profile Heat Sink Design , 2010 .

[2]  Cullen E. Bash,et al.  Energy Flow in the Information Technology Stack: Introducing the Coefficient of Performance of the Ensemble , 2006 .

[3]  E M Sparrow,et al.  Analysis of laminar forced-convection heat transfer in entrance region of flat rectangular ducts , 1955 .

[4]  C.E. Bash,et al.  The sustainable information technology ecosystem , 2008, 2008 11th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems.

[5]  M. Yovanovich,et al.  Analytical forced convection modeling of plate fin heat sinks , 1999, Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306).

[6]  Jeff Punch,et al.  Heat Transfer From Novel Target Surface Structures to a Normally Impinging, Submerged and Confined Water Jet , 2009 .

[7]  B. Sammakia,et al.  Experimental-Numerical Comparison for a High-Density Data Center: Hot Spot Heat Fluxes in Excess of 500 W/ft $^{2}$ , 2009, IEEE Transactions on Components and Packaging Technologies.

[8]  R. Schmidt,et al.  Experimental-Numerical Comparison for a High-Density Data Center: Hot Spot Heat Fluxes in Excess of 500 W/FT2 , 2006, Thermal and Thermomechanical Proceedings 10th Intersociety Conference on Phenomena in Electronics Systems, 2006. ITHERM 2006..

[9]  Jeffrey Rambo,et al.  Modeling of data center airflow and heat transfer: State of the art and future trends , 2007, Distributed and Parallel Databases.

[10]  Manish Marwah,et al.  Integrated Design and Management of a Sustainable Data Center , 2009 .

[11]  C. Bash,et al.  Exergy Analysis of Data Center Thermal Management Systems , 2008 .

[12]  Bahgat Sammakia,et al.  Optimization of data center room layout to minimize rack inlet air temperature , 2006 .

[13]  T. J. Breen,et al.  From chip to cooling tower data center modeling: Part I Influence of server inlet temperature and temperature rise across cabinet , 2010, 2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems.