Electric field changes generated by the preliminary breakdown for the negative cloud-to-ground lightning flashes in Malaysia and Sweden

Abstract We present the study of the electric field changes generated by the preliminary breakdown for negative cloud-to-ground lightning flashes in Malaysia and Sweden concerning the association of slow field changes associated in preliminary breakdown process. We examined the total of 1685 negative cloud-to-ground lightning flashes from the total of 39 thunderstorms by recording the slow electric field, fast electric field and narrowband radiation field at 3 and 30 MHz signals simultaneously. Our results show that there is a pre-starting time, i.e. the duration between the first preliminary breakdown pulse and slow field changes starting point, which is found to be after the first preliminary breakdown pulse. The pre-starting time has the arithmetic and geometric mean range from 1.4–6.47 and 1–3.36 ms, respectively. The mean values of pre-starting time in Malaysia are greater than the values observed in Sweden by more than a factor of 3. From the two data sets it shows that the slow field changes never start before the preliminary breakdown. Furthermore, the use of single-station electric fields measurement with high resolutions of 12 bits transient recorder with several nanosecond accuracy allow one to distinguish the slow field changes generated by preliminary breakdown, which preceded the negative first return stroke, between tens to hundreds of milliseconds of pre-return stroke duration.

[1]  E. M. Thomson Characteristics of Port Moresby ground flashes , 1980 .

[2]  Paul Krehbiel,et al.  Interferometric observations of a single stroke cloud‐to‐ground flash , 1989 .

[3]  D. J. Malan,et al.  Preliminary discharge processes in lightning flashes to ground , 1957 .

[4]  D. J. Harris,et al.  The measurement of lightning characteristics in northern Nigeria , 1972 .

[5]  Vernon Cooray,et al.  On the characteristics of some radiation fields from lightning and their possible origin in positive ground flashes , 1982 .

[6]  T. Takeuti,et al.  ON THE CLOUD DISCHARGE PRECEDING THE FIRST GROUND STROKE , 1960 .

[7]  Paul Krehbiel,et al.  An analysis of the charge structure of lightning discharges to ground , 1979 .

[8]  D. E. Proctor,et al.  VHF radio pictures of lightning flashes to ground , 1988 .

[9]  Martin A. Uman,et al.  Electric fields preceding cloud‐to‐ground lightning flashes , 1982 .

[10]  Vernon Cooray,et al.  Comparative study on preliminary breakdown pulse trains observed in Johor, Malaysia and Florida, USA , 2012 .

[11]  N. Kitagawa,et al.  A comparison of intracloud and cloud-to-ground lightning discharges , 1960 .

[12]  A Galván,et al.  Operative characteristics of a parallel-plate antenna to measure vertical electric fields from lightning flashes , 2000 .

[13]  Vernon Cooray,et al.  The lightning flash , 2003 .

[14]  Vernon Cooray,et al.  Properties of preliminary breakdown processes in Scandinavian lightning , 2008 .

[15]  Vladimir A. Rakov,et al.  Pulse trains that are characteristic of preliminary breakdown in cloud‐to‐ground lightning but are not followed by return stroke pulses , 2008 .

[16]  Basil Ferdinand Jamieson Schonland,et al.  Progressive Lightning. V. A Comparison of Photographic and Electrical Studies of the Discharge Process , 1938 .