Simultaneous measurement of wall shear stress and arterial distension in FMD studies

In Flow-mediated dilation (FMD) studies, blood flow in the brachial artery is restricted for about 5 minutes by a cuff. When the restriction is removed, the subsequent increase in wall shear rate (WSR) stimulates the release of nitric oxide, a vasodilator, from the endothelial cells into the smooth muscle. Impaired FMD responses, which are considered independent predictors of possible cardiovascular events, should be reliably detected. While several efforts have been so far dedicated to measure the diameter change, the source of this change, i.e., the WSR increase, has not been measured so far. In this paper, first results of the simultaneous measurement of WSR and diameter performed during FMD studies in the brachial arteries of 15 volunteers are reported. All measurements were obtained through the ULtrasound Advanced Open Platform (ULA-OP).

[1]  R. Reneman,et al.  An integrated system for the non-invasive assessment of vessel wall and hemodynamic properties of large arteries by means of ultrasound. , 1999, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[2]  F Beux,et al.  Automatic evaluation of arterial diameter variation from vascular echographic images. , 2001, Ultrasound in medicine & biology.

[3]  J. Lekakis,et al.  Assessment of vascular wall shear stress and implications for atherosclerotic disease. , 2006, International journal of cardiology.

[4]  D. Spiegelhalter,et al.  Non-invasive measurement of human endothelium dependent arterial responses: accuracy and reproducibility. , 1995, British heart journal.

[5]  D. Celermajer,et al.  Endothelium-dependent dilation in the systemic arteries of asymptomatic subjects relates to coronary risk factors and their interaction. , 1994, Journal of the American College of Cardiology.

[6]  R. Hughson,et al.  Flow-mediated dilation in human brachial artery after different circulatory occlusion conditions. , 2004, American journal of physiology. Heart and circulatory physiology.

[7]  P. Tortoli,et al.  Improved blood velocity estimation using the maximum Doppler frequency. , 1995, Ultrasound in medicine & biology.

[8]  A. Gnasso,et al.  Association between wall shear stress and flow-mediated vasodilation in healthy men. , 2001, Atherosclerosis.

[9]  H Ermert,et al.  Real-time Detection of Vessel Diameters with Ultrasound. Echtzeiterkennung von Gefäßdurchmessern mit Ultraschall , 2003, Biomedizinische Technik. Biomedical engineering.

[10]  Marcello Demi,et al.  A System for Real-Time Measurement of the Brachial Artery Diameter in B-Mode Ultrasound Images , 2007, IEEE Transactions on Medical Imaging.

[11]  K. Pyke,et al.  Peak vs. total reactive hyperemia: which determines the magnitude of flow-mediated dilation? , 2007, Journal of applied physiology.

[12]  V R Newey,et al.  Online artery diameter measurement in ultrasound images using artificial neural networks. , 2002, Ultrasound in medicine & biology.

[13]  K. Pyke,et al.  Impact of controlling shear rate on flow-mediated dilation responses in the brachial artery of humans. , 2004, Journal of applied physiology.

[14]  Marcello Demi,et al.  The First Absolute Central Moment in Low-Level Image Processing , 2000, Comput. Vis. Image Underst..

[15]  K. Pyke,et al.  Are the dynamic response characteristics of brachial artery flow-mediated dilation sensitive to the magnitude of increase in shear stimulus? , 2008, Journal of applied physiology.

[16]  D. Wray,et al.  Evidence of preserved endothelial function and vascular plasticity with age. , 2006, American journal of physiology. Heart and circulatory physiology.

[17]  Ryan A. Harris,et al.  Ultrasound Assessment of Flow-Mediated Dilation , 2010, Hypertension.

[18]  R. Cobbold,et al.  Comparison of four digital maximum frequency estimators for Doppler ultrasound. , 1988, Ultrasound in medicine & biology.