The Design, Control, and Testing of an Integrated Electrohydrostatic Powered Ankle Prosthesis

This paper presents a prototype powered ankle prosthesis that can operate passively in most of the gait cycle and provide powered assistance for toe push-off and subsequent foot dorsiflexion. The use of an electrohydrostatic actuator (EHA) gives the ability to switch quickly and smoothly between passive and active modes. In this new powered ankle prosthesis, the motor–pump unit is integrated with the ankle joint and the battery and controller are held in a backpack. A 100 W brushless dc motor is used to drive a 0.45 cc/rev gear pump, controlling flow to an ankle cylinder through a bespoke manifold. The motor runs wet, pressurized to 6 MPa, avoiding the need for a pump shaft seal and a refeeding circuit for external leakage. A dynamic system model has been develop to help analyze the EHA performance. A motor control method is proposed based on heel strike recognition and a middle stance time delay. The prosthesis has been tested with a 70 kg transtibial amputee, and results are presented for walking on a treadmill at three different speeds (2.8, 3.8, and 4.8 km/h). The amputee has provided positive subjective feedback. We conclude that the hybrid passive–active approach has significant advantages for prosthesis design, and we outline future testing and development requirements.

[1]  Hugh M. Herr,et al.  Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy , 2009, IEEE Transactions on Robotics.

[2]  H.A. Varol,et al.  Design and control of an active electrical knee and ankle prosthesis , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[3]  Alena M. Grabowski,et al.  Bionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation , 2012, Proceedings of the Royal Society B: Biological Sciences.

[4]  R. Riener,et al.  Stair ascent and descent at different inclinations. , 2002, Gait & posture.

[5]  H.A. Varol,et al.  Preliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis , 2009, IEEE/ASME Transactions on Mechatronics.

[6]  Scott Tashman,et al.  Development of hybrid orthosis for standing, walking, and stair climbing after spinal cord injury. , 2009, Journal of rehabilitation research and development.

[7]  Homayoon Kazerooni,et al.  Design of a semi-active knee-ankle prosthesis , 2011, 2011 IEEE International Conference on Robotics and Automation.

[8]  H.A. Varol,et al.  Real-time gait mode intent recognition of a powered knee and ankle prosthesis for standing and walking , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[9]  Amit Kulshreshtha,et al.  Electric Actuation For Flight & Engine Control System: Evolution, Current Trends & Future Challenges , 2007 .

[10]  Thomas Sugar,et al.  Dynamically Controlled Ankle-Foot Orthosis (DCO) with Regenerative Kinetics: Incrementally Attaining User Portability , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[11]  Yifan David Li,et al.  Gait mode recognition and control for a portable-powered ankle-foot orthosis , 2013, 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR).

[12]  Hao Zheng,et al.  Design and Control of a Pneumatically Actuated Transtibial Prosthesis , 2015, Journal of bionic engineering.

[13]  R Jiménez-Fabián,et al.  Review of control algorithms for robotic ankle systems in lower-limb orthoses, prostheses, and exoskeletons. , 2012, Medical engineering & physics.

[14]  Andrew Plummer,et al.  The Design of a Powered Ankle Prosthesis With Electrohydrostatic Actuation , 2015 .

[15]  Qining Wang,et al.  Combining Push-Off Power and Nonlinear Damping Behaviors for a Lightweight Motor-Driven Transtibial Prosthesis , 2017, IEEE/ASME Transactions on Mechatronics.

[16]  Homayoon Kazerooni,et al.  Design of a semi-active knee prosthesis , 2009, 2009 IEEE International Conference on Robotics and Automation.

[17]  Hugh Herr,et al.  User-adaptive control of a magnetorheological prosthetic knee , 2003, Ind. Robot.

[18]  D. Lefeber,et al.  A pneumatically powered below-knee prosthesis: Design specifications and first experiments with an amputee , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[19]  Robert Riener,et al.  Control strategies for active lower extremity prosthetics and orthotics: a review , 2015, Journal of NeuroEngineering and Rehabilitation.

[20]  Thomas G. Sugar,et al.  An Active Foot-Ankle Prosthesis With Biomechanical Energy Regeneration , 2010 .

[21]  Andrew Plummer,et al.  Testing an Electrohydrostatic Powered Ankle Prosthesis with Transtibial and Transfemoral Amputees , 2016 .

[22]  Jicheng Xia,et al.  Technologies for Powered Ankle-Foot Orthotic Systems: Possibilities and Challenges , 2013, IEEE/ASME Transactions on Mechatronics.

[23]  Donaldson McCloy,et al.  Control of fluid power : analysis and design , 1980 .

[24]  Ming Liu,et al.  Effects of Locomotion Mode Recognition Errors on Volitional Control of Powered Above-Knee Prostheses , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[25]  Hugh M. Herr,et al.  Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits , 2008, Neural Networks.

[26]  Long Wang,et al.  Energy-Efficient Braking Torque Control of Robotic Transtibial Prosthesis , 2017, IEEE/ASME Transactions on Mechatronics.

[27]  Tianhao Yu Actuation and control of lower limb prostheses , 2017 .