Numerical investigation of the effects of cannula geometry on hydraulic blood flow to prevent the risk of thrombosis

Despite significant advances in left ventricular assist devices and the cannula, unfavorable events leading to the death of patients, including bleeding, infection, neurological disorders, hemolysis, and thrombosis, are still being reported. Local parameters of blood flow, including static flow, vorticity and critical values of shear stress on the wall of ventricle and cannula, increase the risk of thrombosis. Therefore, the analysis of blood flow domains inside the ventricle and cannula is necessary to investigate the probability of forming thrombosis in the cannula of left ventricular assist devices. In this study, blood flow is investigated in a Medtronic DLP 16F clinical cannula by using computational fluid dynamics through three-dimensional modeling of the left ventricle and cannula based on real geometry. Apart from the fact that blood is considered non-Newtonian fluid, the effect of heart movement in the left ventricle is also applied. In this research, blood flow in the cannula has been examined and some problems resulting from the use of the cannulas have been investigated. The results indicate that changing the geometry of input holes, such as their number and size, on the tip of the cannula, alter the probability of forming thrombosis and the standard mode shows a better performance.

[1]  H. Oertel,et al.  Fluid-Structure Coupled CFD Simulation of the Left Ventricular Flow During Filling Phase , 2005, Annals of Biomedical Engineering.

[2]  E. Tatsumi,et al.  Development and hydrodynamic evaluation of a novel inflow cannula in a mechanical circulatory support system for bridge to decision. , 2011, Artificial organs.

[3]  Gino Gerosa,et al.  Influence of inflow cannula length in axial-flow pumps on neurologic adverse event rate: results from a multi-center analysis. , 2008, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  K. May-Newman The Importance of Left Ventricular Assist Device Inflow Cannula Angle, and the Relationship to Cardiac and Anatomical Geometry. , 2019, ASAIO journal.

[5]  H. Niazmand,et al.  Numerical investigation of drug delivery by using magnetic field in a 90-degree bent vessel: a 3D simulation , 2020, Biomechanics and Modeling in Mechanobiology.

[6]  Steven Deutsch,et al.  Correlation of In Vivo Clot Deposition With the Flow Characteristics in the 50 cc Penn State Artificial Heart: A Preliminary Study , 2004, ASAIO journal.

[7]  Javad Sodagar-Abardeh,et al.  Numerical study of drug delivery through the 3D modeling of aortic arch in presence of a magnetic field , 2021, Biomechanics and Modeling in Mechanobiology.

[8]  Michael Neidlin,et al.  Title: Ventricular flow dynamics with varying LVAD inflow cannula lengths: in-silico evaluation in a multiscale model Type of work: Original Article Running head: Influence of LVAD inflow cannula insertion length , 2018 .

[9]  G. Karniadakis,et al.  Combined effects of pulsatile flow and dynamic curvature on wall shear stress in a coronary artery bifurcation model. , 2005, Journal of biomechanics.

[10]  Ulrich Steinseifer,et al.  Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch. , 2010, Artificial organs.

[11]  J. Kirkpatrick,et al.  Left Ventricular Assist Device Inflow Cannula Insertion Depth Influences Thrombosis Risk , 2019, ASAIO journal.

[12]  E. Tatsumi,et al.  Computational fluid dynamic analysis of the flow field in the newly developed inflow cannula for a bridge-to-decision mechanical circulatory support , 2011, Journal of Artificial Organs.

[13]  Socrates Dokos,et al.  Numerical investigation of the effect of cannula placement on thrombosis , 2013, Theoretical Biology and Medical Modelling.

[14]  Bart Meyns,et al.  Clinical results with an ePTFE inflow conduit for mechanical circulatory support. , 2004, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[15]  H. Schima,et al.  Special considerations on the implantation technique for the MicroMed-DeBakey ventricular assist device axial pump. , 2003, Annals of Thoracic Surgery.

[16]  K. Vahedi,et al.  Numerical analysis of magnetic field effects on hydro-thermal behavior of a magnetic nanofluid in a double pipe heat exchanger , 2016 .

[17]  Shengshou Hu,et al.  [Numerical simulation of LVAD inflow cannulas with different tips]. , 2012, Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi.

[18]  Danny Bluestein,et al.  Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. , 2007, Artificial organs.

[19]  A. Aliseda,et al.  Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk , 2018, Circulation. Heart failure.

[20]  Maud Gorbet,et al.  The effect of shear on in vitro platelet and leukocyte material-induced activation , 2013, Journal of biomaterials applications.

[21]  Tao Zhang,et al.  Computational Fluid Dynamics Analysis of Thrombosis Potential in Left Ventricular Assist Device Drainage Cannulae , 2010, ASAIO journal.

[22]  B. Min,et al.  A numerical study on the effect of side hole number and arrangement in venous cannulae. , 2007, Journal of biomechanics.

[23]  S. Gregory,et al.  Numerical prediction of thrombus risk in an anatomically dilated left ventricle: the effect of inflow cannula designs , 2016, Biomedical engineering online.

[24]  D. Zimpfer,et al.  The influence of left ventricular assist device inflow cannula position on thrombosis risk , 2020, Artificial organs.