Assessment of Partial Least-Squares Calibration and Wavelength Selection for Complex Near-Infrared Spectra

Complex near-infrared (near-IR) spectra of aqueous solutions containing five independently varying absorbing species were collected to assess the ability of partial least-squares (PLS) regression and wavelength selection for calibration and prediction of these species in the presence of each other. It was confirmed that PLS calibration models can successfully predict chemical concentrations of all five chemicals from a single spectrum. It was observed from the PLS spectral loadings that spectral regions containing absorption bands of a single analyte alone were not sufficient for the model to adequately predict the concentration of the analyte because of the high degree of overlap between glucose, lactate, ammonia, glutamate, and glutamine. Three wavelength selection algorithms were applied to the spectra to identify regions containing necessary information, and in each case it was found that nearly the entire spectral range was needed for each determination. The results suggest that wavelength selection does result in a reduction of data points from the full spectrum, but the decrease seen with these near-infrared spectra was less than typically seen in mid-IR or Raman spectra, where peaks are narrower and well separated. As a result of this need for more wavelengths, the engineering of a dedicated system to measure these analytes in complex media such as blood or tissue culture broths by using this near-infrared region (2.0–2.5 μm) is further complicated.

[1]  C. B. Lucasius,et al.  Genetic algorithms for large-scale optimization in chemometrics: An application , 1991 .

[2]  Philip J. Brown,et al.  Wavelength selection in multicomponent near‐infrared calibration , 1992 .

[3]  Riccardo Leardi,et al.  Genetic Algorithms as a Tool for Wavelength Selection in Multivariate Calibration , 1995 .

[4]  Michael J. McShane,et al.  Variable Selection in Multivariate Calibration of a Spectroscopic Glucose Sensor , 1997 .

[5]  Mark A. Arnold,et al.  Simultaneous Measurements of Glucose, Glutamine, Ammonia, Lactate, and Glutamate in Aqueous Solutions by Near-Infrared Spectroscopy , 1996 .

[6]  C. Spiegelman,et al.  Theoretical Justification of Wavelength Selection in PLS Calibration:  Development of a New Algorithm. , 1998, Analytical Chemistry.

[7]  Paul J. Gemperline,et al.  Mixture analysis using factor analysis I: Calibration and quantitation , 1989 .

[8]  F.M. Ham,et al.  Determination of glucose concentrations in an aqueous matrix from NIR spectra using optimal time-domain filtering and partial least-squares regression , 1997, IEEE Transactions on Biomedical Engineering.

[9]  M A Arnold,et al.  Near-infrared spectroscopic measurement of glucose in a protein matrix. , 1993, Analytical chemistry.

[10]  Avraham Lorber,et al.  The effect of interferences and calbiration design on accuracy: Implications for sensor and sample selection , 1988 .

[11]  M A Arnold,et al.  Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides. , 1996, Analytical chemistry.

[12]  M A Arnold,et al.  Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares regression: application to near-infrared spectroscopy. , 1996, Analytical chemistry.

[13]  M A Arnold,et al.  Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectra. , 1990, Analytical chemistry.

[14]  Chris W. Brown,et al.  Matrix representations and criteria for selecting analytical wavelengths for multicomponent spectroscopic analysis , 1982 .

[15]  Clifford H. Spiegelman,et al.  Chemometrics and spectral frequency selection , 1991, Philosophical Transactions of the Royal Society of London. Series A: Physical and Engineering Sciences.

[16]  M A Arnold,et al.  Strategies for coupling digital filtering with partial least-squares regression: application to the determination of glucose in plasma by Fourier transform near-infrared spectroscopy. , 1993, Analytical chemistry.

[17]  D. T. Rossi,et al.  Effects of wavelength range on the simultaneous quantitation of polynuclear aromatic hydrocarbons with absorption spectra , 1985 .

[18]  E. V. Thomas,et al.  Partial least-squares methods for spectral analyses. 1. Relation to other quantitative calibration methods and the extraction of qualitative information , 1988 .

[19]  Kevin H. Hazen,et al.  Temperature-Insensitive Near-Infrared Spectroscopic Measurement of Glucose in Aqueous Solutions , 1994 .