A Wearable Device to Support the Pull Test in Parkinson Disease

The Pull Test is a common practice to assess the postural instability of patients with Parkinson Disease. Postural instability is a serious issue for elderly and people with neurological disease, which can cause falls. The implementation of the Pull Test consists in observing the user response after providing a tug to the patients’ shoulders, in order to displace the center of gravity from its neutral position. The validity of the test can be compromised by a nonstandard backward tug provided to the patient. The solution proposed in this paper consists of a low cost multisensor system allowing an objective estimation of the input solicitation. Moreover, the system provides supplementary information on the user postural instability, by means of a set of features extracted from the user stabilogram, which are useful to assess the user response. A wide set of experiments have been performed to assess the system capability to provide a rough classification between stable and unstable behaviors. Results obtained demonstrate the validity of the approach proposed.

[1]  Marco Pirola,et al.  Low-cost wearable measurement system for continuous real-time pedobarography , 2015, 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings.

[2]  B. Ando,et al.  A Smart Multisensor Approach to Assist Blind People in Specific Urban Navigation Tasks , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[3]  Bruno Ando,et al.  An Event Polarized Paradigm for ADL Detection in AAL Context , 2015, IEEE Transactions on Instrumentation and Measurement.

[4]  Bruno Ando,et al.  A Multisensor Data-Fusion Approach for ADL and Fall classification , 2016, IEEE Transactions on Instrumentation and Measurement.

[5]  Salvatore Graziani,et al.  Multisensor Strategies to Assist Blind People: A Clear-Path Indicator , 2009, IEEE Transactions on Instrumentation and Measurement.

[6]  Bruno Ando,et al.  A multisensor approach to perform instrumented postural instability tests for patient with Parkinson disease , 2016, 2016 IEEE Sensors Applications Symposium (SAS).

[7]  J. Collins,et al.  Open-loop and closed-loop control of posture: A random-walk analysis of center-of-pressure trajectories , 2004, Experimental Brain Research.

[8]  Björn Eskofier,et al.  Pull test estimation in Parkinson's disease patients using wearable sensor technology , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[9]  W A Ray,et al.  Clinical and biomechanical measures of balance as fall predictors in ambulatory nursing home residents. , 1996, The journals of gerontology. Series A, Biological sciences and medical sciences.

[10]  Ann L. Hunt Do,et al.  The pull test: A history , 2006 .

[11]  James A. Norris,et al.  Ability of static and statistical mechanics posturographic measures to distinguish between age and fall risk. , 2005, Journal of biomechanics.

[12]  H. Neuhauser Epidemiology of vertigo , 2007, Current opinion in neurology.

[13]  Bruno Ando,et al.  Intelligent Sensing Solutions for AAL , 2014 .

[14]  B. Ando,et al.  A multisensor architecture for the assessment of postural sway in elderly and people with neurological disease , 2017, 2017 IEEE Sensors Applications Symposium (SAS).

[15]  J. Kofman,et al.  Review of fall risk assessment in geriatric populations using inertial sensors , 2013, Journal of NeuroEngineering and Rehabilitation.

[16]  Bruno Ando,et al.  Fall & ADL Detection Methodologies for AAL , 2015 .

[17]  Joseph Jankovic,et al.  Motor fluctuations and dyskinesias in Parkinson's disease: Clinical manifestations , 2005, Movement disorders : official journal of the Movement Disorder Society.

[18]  Salvatore Baglio,et al.  A Wearable Device to Support the Pull Test for Postural Instability Assessment in Parkinson’s Disease , 2018, IEEE Transactions on Instrumentation and Measurement.

[19]  Bruno Ando,et al.  ADL Detection for the Active Ageing of Elderly People , 2015 .

[20]  Salvatore Baglio,et al.  A Sensing Architecture for Mutual User-Environment Awareness Case of Study: A Mobility Aid for the Visually Impaired , 2011, IEEE Sensors Journal.

[21]  René Schwendimann,et al.  Patient falls : a key issue in patient safety in hospitals , 2006 .

[22]  Y Eggli,et al.  Risk of falls for hospitalized patients: a predictive model based on routinely available data. , 2001, Journal of clinical epidemiology.

[23]  John Lach,et al.  Fall Risk Prediction Using Wearable Wireless Sensors , 2014 .

[24]  Attila Priplata,et al.  Noise-enhanced human balance control. , 2002, Physical review letters.

[25]  Bruno Ando,et al.  A multi-user assistive system for the user safety monitoring in care facilities , 2015, 2015 IEEE International Workshop on Measurements & Networking (M&N).

[26]  Orthopaedic Surgeons Panel On Falls Prevention Guideline for the Prevention of Falls in Older Persons , 2001 .

[27]  B. Ando,et al.  Instrumentation notes - Sensors that provide security for people with depressed receptors , 2006, IEEE Instrumentation & Measurement Magazine.

[28]  Simona Crea,et al.  A Wireless Flexible Sensorized Insole for Gait Analysis , 2014, Sensors.

[29]  Inmaculada Plaza,et al.  Challenges, issues and trends in fall detection systems , 2013, Biomedical engineering online.

[30]  K. Sethi,et al.  The pull test: A history , 2006, Movement disorders : official journal of the Movement Disorder Society.

[31]  F. Horak,et al.  The relevance of clinical balance assessment tools to differentiate balance deficits. , 2010, European journal of physical and rehabilitation medicine.