Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer.

PURPOSE To compare the accuracy of imaging modalities, immobilization, localization, and positioning techniques in patients with prostate cancer. METHODS AND MATERIALS Thirty-five patients with prostate cancer had gold marker seeds implanted transrectally and were treated with fractionated radiotherapy. Twenty of the 35 patients had limited immobilization; the remaining had a vacuum-based immobilization. Patient positioning consisted of alignment with lasers to skin marks, ultrasound or kilovoltage X-ray imaging, optical guidance using infrared reflectors, and megavoltage electronic portal imaging (EPI). The variance of each positioning technique was compared to the patient position determined from the pretreatment EPI. RESULTS With limited immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 9.1 +/- 5.3 mm, the average difference between the skin marks' infrared position and EPI pretreatment position is 11.8 +/- 7.2 mm, the average difference between the ultrasound position and EPI pretreatment position is 7.0 +/- 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 3.5 +/- 3.1 mm, and the average intrafraction movement during treatment is 3.4 +/- 2.7 mm. For the patients with the vacuum-style immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 10.7 +/- 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 1.9 +/- 1.5 mm, and the average intrafraction movement during treatment is 2.1 +/- 1.5 mm. CONCLUSIONS Compared with use of skin marks, ultrasound imaging for positioning provides an increased degree of agreement to EPI-based positioning, though not as favorable as kV imaging fiducial seeds. Intrafraction movement during treatment decreases with improved immobilization.

[1]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[2]  M M Urie,et al.  Conformal irradiation of the prostate: estimating long-term rectal bleeding risk using dose-volume histograms. , 1996, International journal of radiation oncology, biology, physics.

[3]  Daniel W. Miller,et al.  Comparison of conventional-dose vs high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate: a randomized controlled trial. , 2005, JAMA.

[4]  C C Ling,et al.  High dose radiation delivered by intensity modulated conformal radiotherapy improves the outcome of localized prostate cancer. , 2001, The Journal of urology.

[5]  Patrick A. Kupelian,et al.  Daily transabdominal ultrasound localization of the prostate gland with the BAT system: 2705 alignments from 100 patients , 2000 .

[6]  T R Willoughby,et al.  Short-course intensity-modulated radiotherapy for localized prostate cancer with daily transabdominal ultrasound localization of the prostate gland. , 2000, International journal of radiation oncology, biology, physics.

[7]  M. V. van Herk,et al.  Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). , 2005, International journal of radiation oncology, biology, physics.

[8]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[9]  G Starkschall,et al.  Preliminary results of a randomized radiotherapy dose-escalation study comparing 70 Gy with 78 Gy for prostate cancer. , 2000, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[10]  A. Markoe,et al.  Preliminary report of toxicity following 3D radiation therapy for prostate cancer on 3DOG/RTOG 9406. , 2000, International journal of radiation oncology, biology, physics.

[11]  J Szanto,et al.  Respiratory-induced prostate motion: quantification and characterization. , 2000, International journal of radiation oncology, biology, physics.

[12]  D P Dearnaley,et al.  Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. , 1999, International journal of radiation oncology, biology, physics.

[13]  Ping Xia,et al.  Low-dose megavoltage cone-beam CT for radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[14]  Patrick A Kupelian,et al.  Initial experience with megavoltage (MV) CT guidance for daily prostate alignments. , 2005, International journal of radiation oncology, biology, physics.

[15]  Michael G Herman,et al.  Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device. , 2003, International journal of radiation oncology, biology, physics.

[16]  Douglas L. Jones ICRU Report 50—Prescribing, Recording and Reporting Photon Beam Therapy , 1994 .

[17]  Hilke Vorwerk,et al.  Interfractional and intrafractional accuracy during radiotherapy of gynecologic carcinomas: a comprehensive evaluation using the ExacTrac system. , 2003, International journal of radiation oncology, biology, physics.

[18]  Benjamin Movsas,et al.  Measurement of intrafractional prostate motion using magnetic resonance imaging. , 2002, International journal of radiation oncology, biology, physics.

[19]  E. B. Butler,et al.  Intensity-modulated radiation therapy (IMRT) for prostate cancer with the use of a rectal balloon for prostate immobilization: acute toxicity and dose-volume analysis. , 2001, International journal of radiation oncology, biology, physics.

[20]  Martin J Murphy,et al.  Tracking moving organs in real time. , 2004, Seminars in radiation oncology.

[21]  Jan J W Lagendijk,et al.  Measurements and clinical consequences of prostate motion during a radiotherapy fraction. , 2002, International journal of radiation oncology, biology, physics.

[22]  T E Schultheiss,et al.  A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[23]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[24]  2201 A method to combine three dimensional dose distributions for external beam and brachytherapy radiation treatments for gynecological neoplasms , 1997 .

[25]  M Goitein,et al.  Late rectal bleeding following combined X-ray and proton high dose irradiation for patients with stages T3-T4 prostate carcinoma. , 1993, International journal of radiation oncology, biology, physics.

[26]  Frank Van den Heuvel,et al.  Independent verification of ultrasound based image-guided radiation treatment, using electronic portal imaging and implanted gold markers. , 2003, Medical physics.

[27]  H Shirato,et al.  Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. , 2000, International journal of radiation oncology, biology, physics.

[28]  H Alasti,et al.  Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate. , 2001, International journal of radiation oncology, biology, physics.

[29]  K Lam,et al.  Measurement of prostate movement over the course of routine radiotherapy using implanted markers. , 1995, International journal of radiation oncology, biology, physics.

[30]  T E Schultheiss,et al.  Dose escalation with 3D conformal treatment: five year outcomes, treatment optimization, and future directions. , 1998, International journal of radiation oncology, biology, physics.

[31]  J. Pouliot,et al.  Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[32]  Lei Dong,et al.  Intrafraction prostate motion during IMRT for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[33]  Radhe Mohan,et al.  Near simultaneous computed tomography image-guided stereotactic spinal radiotherapy: an emerging paradigm for achieving true stereotaxy. , 2003, International journal of radiation oncology, biology, physics.

[34]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[35]  Lisa Grimm,et al.  Image-guided radiotherapy for prostate cancer by CT-linear accelerator combination: prostate movements and dosimetric considerations. , 2005, International journal of radiation oncology, biology, physics.

[36]  Hui Yan,et al.  A phantom study on the positioning accuracy of the Novalis Body system. , 2003, Medical physics.

[37]  Michael G Herman,et al.  Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging. , 2005, International journal of radiation oncology, biology, physics.

[38]  C. Ling,et al.  Late rectal toxicity after conformal radiotherapy of prostate cancer (I): multivariate analysis and dose-response. , 2000, International journal of radiation oncology, biology, physics.

[39]  P L Roberson,et al.  Impact of ultrasound and computed tomography prostate volume registration on evaluation of permanent prostate implants. , 1997, International journal of radiation oncology, biology, physics.

[40]  Gary A Ezzell,et al.  Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[41]  Shinichi Shimizu,et al.  Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions. , 2002, International journal of radiation oncology, biology, physics.

[42]  C. Langer,et al.  Concurrent chemoradiation using paclitaxel and carboplatin in locally advanced non-small cell lung cancer. , 1999, Seminars in radiation oncology.

[43]  Stanley J. Rosenthal,et al.  Moving targets: detection and tracking of internal organ motion for treatment planning and patient set-up. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.