Respiration signal extraction from photoplethysmogram using pulse wave amplitude variation

Respiratory information is usually measured directly with chest and abdominal belt or from the nasal airflow. There are several methods to extract respiration also from the electrocardiogram (ECG) and photoplethysmogram (PPG). In this paper we propose a methodology that detects the amplitude changes in the PPG signal to estimate the respiration rate. During exhalation, our parasympathetic nervous system makes the blood vessels more flexible than during inhalation. Blood vessels flexibility affects the propagation velocity of the pulse wave. In that way respiration also modulates the amplitude of the pulse wave signal. Comparing with other respiration signal extraction techniques our method has excellent results with limited processing power. The long-term objective of this work is to use the respiration signal together with heart rate and blood oxygen saturation level (SpO2), that are extracted from the pulse wave, for sleep apnea detection and screening purposes.

[1]  R. Jaafar,et al.  Using pulse oximetry method as a non invasive indicator of blood perfusion in neonates , 2011, 2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering.

[2]  Syeda Quratulain Ali,et al.  DWPT based sleep apnea detection , 2011, 2011 National Postgraduate Conference.

[3]  P. Laguna,et al.  Deriving respiration from the pulse photoplethysmographic signal , 2011, 2011 Computing in Cardiology.

[4]  Wei Chen,et al.  Innovative Design for Monitoring of Neonates Using Reflectance Pulse Oximeter , 2011, 2011 Seventh International Conference on Intelligent Environments.

[5]  E. Hari Krishna,et al.  Estimation of respiration rate from ECG, BP and PPG signals using empirical mode decomposition , 2011, 2011 IEEE International Instrumentation and Measurement Technology Conference.

[6]  K. Ashoka Reddy,et al.  Computation of SpO2 using non-parametric spectral estimation methods from wavelet based motion artifact reduced PPG signals , 2011, 2011 International Conference on Signal Processing, Communication, Computing and Networking Technologies.

[7]  A. Espiritu Santo,et al.  Respiration rate extraction from ECG signal via discrete wavelet transform , 2010, 2010 2nd Circuits and Systems for Medical and Environmental Applications Workshop (CASME).

[8]  Guan-Zheng Liu,et al.  The accuracy of respiratory rate estimation using electrocardiography and photoplethysmography , 2010, Proceedings of the 10th IEEE International Conference on Information Technology and Applications in Biomedicine.

[9]  K. Reddy,et al.  Monitoring Respiratory Activity Using PPG Signals by Order Reduced-Modified Covariance AR Technique , 2010, 2010 4th International Conference on Bioinformatics and Biomedical Engineering.

[10]  Eduardo Gil,et al.  PTT Variability for Discrimination of Sleep Apnea Related Decreases in the Amplitude Fluctuations of PPG Signal in Children , 2010, IEEE Transactions on Biomedical Engineering.

[11]  Wai Ho Mow,et al.  A smartphone-centric platform for personal health monitoring using wireless wearable biosensors , 2009, 2009 7th International Conference on Information, Communications and Signal Processing (ICICS).

[12]  T. Tamura,et al.  Compensation for two specific types of artifact in pulse wave using a Kalman filter , 2007, 2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine.

[13]  Katsuyuki Miyasaka,et al.  Multiwavelength Pulse Oximetry: Theory for the Future , 2007, Anesthesia and analgesia.

[14]  Wan-Young Chung,et al.  Optimum Place for Measuring Pulse Oximeter Signal in Wireless Sensor-Belt or Wrist-Band , 2007, 2007 International Conference on Convergence Information Technology (ICCIT 2007).

[15]  Xinming Zhang,et al.  A Selective Anchor Node Localization Algorithm for Wireless Sensor Networks , 2007, 2007 International Conference on Convergence Information Technology (ICCIT 2007).

[16]  L. Netchiporouk,et al.  Surveillance of infants at risk of apparent life threatening events (ALTE) with the BBA bootee: a wearable multiparameter monitor , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[17]  Susannah G. Fleming Lionel Tarassenko A Comparison of Signal Processing Techniques for the Extraction of Breathing Rate from the Photoplethysmogram , 2007 .

[18]  Pablo Laguna,et al.  A robust method for ECG-based estimation of the respiratory frequency during stress testing , 2006, IEEE Transactions on Biomedical Engineering.

[19]  J. N. Watson,et al.  A Fully Automated Algorithm for the Determination of Respiratory Rate from the Photoplethysmogram , 2006, Journal of clinical monitoring and computing.

[20]  D. Gozal,et al.  Chapter 18 – Consequences of Obstructive Sleep Apnea Syndrome , 2005 .

[21]  L. Nilsson,et al.  Respiration can be monitored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory mode , 2005, Acta anaesthesiologica Scandinavica.

[22]  PhD David Clifton BEng,et al.  A Fully Automated Algorithm for the Determination of Respiratory Rate from the Photoplethysmogram , 2005, Journal of Clinical Monitoring and Computing.

[23]  Y. Mendelson,et al.  Extracting breathing rate information from a wearable reflectance pulse oximeter sensor , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  W. Fox,et al.  Fetal and Neonatal Physiology , 2003 .

[25]  Jose R. Rodriguez,et al.  Utility of oxygen saturation and heart rate spectral analysis obtained from pulse oximetric recordings in the diagnosis of sleep apnea syndrome. , 2003, Chest.

[26]  J. Salyer,et al.  Neonatal and pediatric pulse oximetry. , 2003, Respiratory care.

[27]  E. Katz,et al.  Pulse Transit Time as a Measure of Arousal and Respiratory Effort in Children with Sleep-Disordered Breathing , 2003, Pediatric Research.

[28]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[29]  R. Golpe,et al.  Utility of home oximetry as a screening test for patients with moderate to severe symptoms of obstructive sleep apnea. , 1999, Sleep.

[30]  F. Sériès,et al.  Utility of Nocturnal Home Oximetry for Case Finding in Patients with Suspected Sleep Apnea Hypopnea Syndrome , 1993, Annals of Internal Medicine.

[31]  W. Guntheroth Sudden infant death syndrome (crib death). , 1977, American heart journal.

[32]  J. Griffin,et al.  Textbook of Medical Physiology 4th Ed , 1971 .

[33]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .