Hemodynamic Behavior of Coronary Stents in Straight and Curved Arteries

Stents are miniature medical devices that can be inserted into arteries and expanded during angioplasty to restore blood flow and prevent arterial collapse. They have been the primary treatment for cardiovascular diseases since the 1990s. However, after stenting, potential risks associated with restenosis may occur, and several studies have shown that stent design could be one of the critical factors in this process. Computational modeling has been widely used as an important tool to predict the clinical performance of stents and hemodynamic behavior in stented arteries. In this study, computational fluid dynamics models were developed to investigate the effects of cardiovascular stent design on the wall shear stress distribution in straight and curved coronary arteries. Results showed that the stent design pattern alone did not have a significant impact on stent hemodynamics; however, stenting in curved arteries increased the low shear stress area, the region where wall shear stress is less than 5 dynes/cm 2 , which may lead to a higher restenosis rate. The total surface area of low wall shear stress almost doubled when the angle of artery curvature increased from 0 o to 90 o . The implication is that stent im- plantation in a tortuous artery greatly increases the risk of restenosis. The proposed methodology and findings show that the presence of a stent in straight or curved arteries alters the flow field and wall shear stress distribution within arteries, providing great insight for the fu- ture design optimization and physician practice to help achieve the best possible clinical outcomes.

[1]  John F LaDisa,et al.  Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries. , 2005, American journal of physiology. Heart and circulatory physiology.

[2]  Hao-Ming Hsiao,et al.  Why similar stent designs cause new clinical issues. , 2012, JACC. Cardiovascular interventions.

[3]  Kuang-Huei Lee,et al.  Computational modeling of effects of intravascular stent design on key mechanical and hemodynamic behavior , 2012, Comput. Aided Des..

[4]  Abdul I. Barakat,et al.  Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents , 2005, Annals of Biomedical Engineering.

[5]  John F LaDisa,et al.  Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling , 2006, Biomedical engineering online.

[6]  S Chien,et al.  Effects of hematocrit and plasma proteins on human blood rheology at low shear rates. , 1966, Journal of applied physiology.

[7]  Örjan Smedby Geometrical Risk Factors for Atherosclerosis in the Femoral Artery: A Longitudinal Angiographic Study , 2004, Annals of Biomedical Engineering.

[8]  Biyue Liu,et al.  The influences of stenosis on the downstream flow pattern in curved arteries. , 2007, Medical engineering & physics.

[9]  R. Mongrain,et al.  [Role of shear stress in atherosclerosis and restenosis after coronary stent implantation]. , 2006, Revista espanola de cardiologia.

[10]  John F LaDisa,et al.  Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery. , 2004, Journal of applied physiology.

[11]  W Rutsch,et al.  A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. , 1994, The New England journal of medicine.

[12]  D. Ku,et al.  Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation: Positive Correlation between Plaque Location and Low and Oscillating Shear Stress , 1985, Arteriosclerosis.

[13]  K Ulm,et al.  Restenosis after coronary placement of various stent types. , 2001, The American journal of cardiology.

[14]  Patrick W Serruys,et al.  A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods , 2009, The Lancet.

[15]  P. Pagel,et al.  Stent Implantation Alters Coronary Artery Hemodynamics and Wall Shear Stress During Maximal Vasodilation. , 2002, Journal of applied physiology.

[16]  Joel L. Berry,et al.  Fluid and Solid Mechanical Implications of Vascular Stenting , 2002, Annals of Biomedical Engineering.

[17]  P. Stone,et al.  Effects of curvature and stenosis-like narrowing on wall shear stress in a coronary artery model with phasic flow. , 1997, Computers and biomedical research, an international journal.

[18]  R. Nerem,et al.  A numerical calculation of flow in a curved tube model of the left main coronary artery. , 1991, Journal of biomechanics.