Innovating lifetime microscopy: a compact and simple tool for life sciences, screening, and diagnostics.

Fluorescence lifetime imaging microscopy (FLIM) allows the investigation of the physicochemical environment of fluorochromes and protein-protein interaction mapping by Forster resonance energy transfer (FRET) in living cells. However, simpler and cheaper solutions are required before this powerful analytical technique finds a broader application in the life sciences. Wide-field frequency-domain FLIM represents a solution whose application is currently limited by the need for multichannel-plate image intensifiers. We recently showed the feasibility of using a charge-coupled device/complementory metal-oxide semiconductor (CCD/CMOS) hybrid lock-in imager, originally developed for 3-D vision, as an add-on device for lifetime measurements on existing wide-field microscopes. In the present work, the performance of the setup is validated by comparison with well-established wide-field frequency-domain FLIM measurements. Furthermore, we combine the lock-in imager with solid-state light sources. This results in a simple, inexpensive, and compact FLIM system, operating at a video rate and capable of single-shot acquisition by virtue of the unique parallel retrieval of two phase-dependent images. This novel FLIM setup is used for cellular and FRET imaging, and for high-throughput and fast imaging applications. The all-solid-state design bridges the technological gap that limits the use of FLIM in areas such as drug discovery and medical diagnostics.

[1]  Alice Biber,et al.  Time-of-flight range imaging with a custom solid state image sensor , 1999, Industrial Lasers and Inspection.

[2]  F. Wouters,et al.  Fluorescence lifetime heterogeneity resolution in the frequency domain by lifetime moments analysis. , 2005, Biophysical journal.

[3]  Robert M. Clegg,et al.  Rapid acquisition, analysis, and display of fluorescence lifetime-resolved images for real-time applications , 1997 .

[4]  S. Landgraf,et al.  Application of semiconductor light sources for investigations of photochemical reactions. , 2001, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[5]  C G Morgan,et al.  Direct modulation of the effective sensitivity of a CCD detector: a new approach to time‐resolved fluorescence imaging , 2002, Journal of microscopy.

[6]  F. Wouters,et al.  All-solid-state lock-in imaging for wide-field fluorescence lifetime sensing. , 2005, Optics express.

[7]  Kevin W Eliceiri,et al.  Analysis of histology specimens using lifetime multiphoton microscopy. , 2003, Journal of biomedical optics.

[8]  P. Selvin Fluorescence resonance energy transfer. , 1995, Methods in enzymology.

[9]  Neil,et al.  Wide‐field optically sectioning fluorescence microscopy with laser illumination , 2000, Journal of microscopy.

[10]  F. Wouters,et al.  Visualization of molecular activities inside living cells with fluorescent labels. , 2004, International review of cytology.

[11]  Alessandro Esposito,et al.  Fluorescence Lifetime Imaging Microscopy , 2004, Current protocols in cell biology.

[12]  David J. S. Birch,et al.  MHz LED source for nanosecond fluorescence sensing , 2002 .

[13]  C G Morgan,et al.  Measurement of nanosecond time‐resolved fluorescence with a directly gated interline CCD camera , 2002, Journal of microscopy.

[14]  F. Wouters,et al.  Imaging biochemistry inside cells. , 2001, Trends in cell biology.

[15]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[16]  M A A Neil,et al.  High-speed wide-field time-gated endoscopic fluorescence-lifetime imaging. , 2004, Optics letters.

[17]  Michael Lehmann,et al.  An all-solid-state optical range camera for 3D real-time imaging with sub-centimeter depth resolution (SwissRanger) , 2004, SPIE Optical Systems Design.

[18]  Gary M. Carter,et al.  Low cost phase-modulation measurements of nanosecond fluorescence lifetimes using a lock-in amplifier , 1999 .

[19]  T. Jovin,et al.  FRET imaging , 2003, Nature Biotechnology.

[20]  E. V. van Munster,et al.  φFLIM: a new method to avoid aliasing in frequency‐domain fluorescence lifetime imaging microscopy , 2004, Journal of microscopy.

[21]  H. Gerritsen,et al.  High Sensitivity Spectrograph for Use in Fluorescence Microscopy , 2001 .

[22]  Ryuichi Shimizu,et al.  Real-time lock-in imaging by a newly developed high-speed image-processing charge coupled device video camera , 2003 .

[23]  B. Maliwal,et al.  Frequency‐domain fluorescence microscopy with the LED as a light source , 2001, Journal of microscopy.

[24]  Peter J. Verveer,et al.  Spectral Imaging in a Programmable Array Microscope by Hadamard Transform Fluorescence Spectroscopy , 1999 .

[25]  Robert M. Clegg,et al.  Fluorescence Lifetime-Resolved Imaging Microscopy: A General Description of Lifetime-Resolved Imaging Measurements , 1996 .

[26]  K. Carlsson,et al.  Theoretical investigation of the signal-to-noise ratio in fluorescence lifetime imaging. , 2003, Journal of the Optical Society of America. A, Optics, image science, and vision.

[27]  D S Elson,et al.  Fluorescence lifetime system for microscopy and multiwell plate imaging with a blue picosecond diode laser. , 2002, Optics letters.

[28]  Hans C. Gerritsen,et al.  Fluorescence Lifetime Imaging, a New Tool in Confocal Microscopy , 1995 .

[29]  U. Haupts,et al.  Developments in fluorescence lifetime-based analysis for ultra-HTS , 2001 .