Length of the Mitral Isthmus But Not Anatomical Location of Ablation Line Predicts Bidirectional Mitral Isthmus Block in Patients Undergoing Catheter Ablation of Persistent Atrial Fibrillation: A Randomized Controlled Trial

Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation.

[1]  K. Kuck,et al.  Catheter ablation of long-standing persistent atrial fibrillation: 5-year outcomes of the Hamburg Sequential Ablation Strategy. , 2012, Journal of the American College of Cardiology.

[2]  T. Betts,et al.  A Review of Mitral Isthmus Ablation , 2012, Indian pacing and electrophysiology journal.

[3]  David Keane,et al.  2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[4]  G. Feld,et al.  Recovery of Mitral Isthmus Conduction Leads to the Development of Macro-Reentrant Tachycardia After Left Atrial Linear Ablation for Atrial Fibrillation , 2011, Circulation. Arrhythmia and electrophysiology.

[5]  S. Matsuo,et al.  Completion of Mitral Isthmus Ablation Using a Steerable Sheath: Prospective Randomized Comparison With a Nonsteerable Sheath , 2011, Journal of cardiovascular electrophysiology.

[6]  Daniel Steven,et al.  Long-term single- and multiple-procedure outcome and predictors of success after catheter ablation for persistent atrial fibrillation. , 2011, Heart rhythm.

[7]  G. Wells,et al.  Approach to the Catheter Ablation Technique of Paroxysmal and Persistent Atrial Fibrillation: A Meta‐Analysis of the Randomized Controlled Trials , 2011, Journal of cardiovascular electrophysiology.

[8]  Ashok J. Shah,et al.  Preprocedural Clinical Parameters Determining Perimitral Conduction Time During Mitral Isthmus Line Ablation , 2011, Circulation. Arrhythmia and electrophysiology.

[9]  H. Pak,et al.  Comparison of voltage map-guided left atrial anterior wall ablation versus left lateral mitral isthmus ablation in patients with persistent atrial fibrillation. , 2011, Heart rhythm.

[10]  A. Skanes,et al.  Reduction in Atrial Flutter Ablation Time by Targeting Maximum Voltage: Results of a Prospective Randomized Clinical Trial , 2009, Journal of cardiovascular electrophysiology.

[11]  S. Knecht,et al.  Long-term follow-up of persistent atrial fibrillation ablation using termination as a procedural endpoint. , 2009, European heart journal.

[12]  Atul Verma,et al.  Ablation for longstanding permanent atrial fibrillation: results from a randomized study comparing three different strategies. , 2008, Heart rhythm.

[13]  S. Knecht,et al.  Left atrial linear lesions are required for successful treatment of persistent atrial fibrillation. , 2008, European heart journal.

[14]  S. Knecht,et al.  How to perform linear lesions. , 2007, Heart rhythm.

[15]  H. Halperin,et al.  Circumferential ablation with pulmonary vein isolation in permanent atrial fibrillation. , 2007, The American journal of cardiology.

[16]  P. Bella,et al.  Left Mitral Isthmus Ablation Associated with PV Isolation: Long‐Term Results of a Prospective Randomized Study , 2005, Journal of cardiovascular electrophysiology.

[17]  Prashanthan Sanders,et al.  Technique and Results of Linear Ablation at the Mitral Isthmus , 2004, Circulation.

[18]  A. Becker Left Atrial Isthmus: , 2004, Journal of cardiovascular electrophysiology.

[19]  D. Shah,et al.  Differential Pacing for Distinguishing Block From Persistent Conduction Through an Ablation Line , 2000, Circulation.

[20]  A. Becker,et al.  Right atrial flutter isthmus revisited: normal anatomy favors nonuniform anisotropic conduction. , 2000, Journal of cardiovascular electrophysiology.

[21]  Wolters Kluwer,et al.  Hrs/ehra/ecas Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design: a Report of the Heart Rhythm Society (hrs) Task Force , 2022 .