Parameter estimation procedures for compact fluorescent lamps with electronic ballasts
暂无分享,去创建一个
[1] N.R. Watson,et al. Modelling of compact fluorescent lamps , 2008, 2008 13th International Conference on Harmonics and Quality of Power.
[2] M. Salichs,et al. Study and Characterization of Waveforms From Low-Watt ($≪$25 W) Compact Fluorescent Lamps With Electronic Ballasts , 2007, IEEE Transactions on Power Delivery.
[3] W. Kling,et al. An analysis of diversity factors applied to harmonic emission limits for energy saving lamps , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.
[4] R.R. Verderber,et al. Harmonics from compact fluorescent lamps , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.
[5] Alexander E. Emanuel,et al. The effect of modern compact fluorescent lights on voltage distortion , 1993 .
[6] Ming-Tong Chen,et al. Characteristics of fluorescent lamps under abnormal system voltage conditions , 1997 .
[7] Frangiskos V. Topalis. Efficiency of energy saving lamps and harmonic distortion in distribution systems , 1993 .
[8] Kenneth Levenberg. A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .
[9] Georgios A. Vokas,et al. Influence of compact fluorescent lamps on the power quality of weak low-voltage networks supplied by autonomous photovoltaic stations , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).
[10] R. Arseneau,et al. The effects of supply harmonics on the performance of compact fluorescent lamps , 1992 .
[11] D. Marquardt. An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .
[12] Jing Yong,et al. A Frequency-Domain Harmonic Model for Compact Fluorescent Lamps , 2010, IEEE Transactions on Power Delivery.
[13] A. Gomez-Exposito,et al. Parameter estimation of harmonic polluting industrial loads , 2004, 2004 International Conference on Probabilistic Methods Applied to Power Systems.
[14] M.B. Payan,et al. A State estimation approach to harmonic polluting load characterization in distribution systems , 2005, IEEE Transactions on Power Systems.
[15] A.B. Nassif,et al. An investigation on the harmonic attenuation effect of modern compact fluorescent lamps , 2008, 2008 13th International Conference on Harmonics and Quality of Power.
[16] F.S. Dos Reis,et al. Nonlinear Loads Parameters Estimation and Modeling , 2007, 2007 IEEE International Symposium on Industrial Electronics.
[17] J. J. Mesas,et al. Parameter Estimation Procedure for Models of Single-Phase Uncontrolled Rectifiers , 2011, IEEE Transactions on Power Delivery.
[18] N.R. Watson,et al. Implications for Distribution Networks of High Penetration of Compact Fluorescent Lamps , 2009, IEEE Transactions on Power Delivery.