Parameter estimation procedures for compact fluorescent lamps with electronic ballasts

Abstract Compact fluorescent lamps (CFLs) are increasingly present in low voltage distribution systems due to their small energy consumption in comparison with traditional incandescent lamps. This damages power quality because CFLs have a non-linear behavior and inject harmonics into the distribution system. This paper studies estimation procedures for CFLs and presents estimation algorithms based on a “black box” CFL model and actual measurements. The estimation procedures are validated with laboratory measurements.

[1]  N.R. Watson,et al.  Modelling of compact fluorescent lamps , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[2]  M. Salichs,et al.  Study and Characterization of Waveforms From Low-Watt ($≪$25 W) Compact Fluorescent Lamps With Electronic Ballasts , 2007, IEEE Transactions on Power Delivery.

[3]  W. Kling,et al.  An analysis of diversity factors applied to harmonic emission limits for energy saving lamps , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[4]  R.R. Verderber,et al.  Harmonics from compact fluorescent lamps , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[5]  Alexander E. Emanuel,et al.  The effect of modern compact fluorescent lights on voltage distortion , 1993 .

[6]  Ming-Tong Chen,et al.  Characteristics of fluorescent lamps under abnormal system voltage conditions , 1997 .

[7]  Frangiskos V. Topalis Efficiency of energy saving lamps and harmonic distortion in distribution systems , 1993 .

[8]  Kenneth Levenberg A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .

[9]  Georgios A. Vokas,et al.  Influence of compact fluorescent lamps on the power quality of weak low-voltage networks supplied by autonomous photovoltaic stations , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[10]  R. Arseneau,et al.  The effects of supply harmonics on the performance of compact fluorescent lamps , 1992 .

[11]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[12]  Jing Yong,et al.  A Frequency-Domain Harmonic Model for Compact Fluorescent Lamps , 2010, IEEE Transactions on Power Delivery.

[13]  A. Gomez-Exposito,et al.  Parameter estimation of harmonic polluting industrial loads , 2004, 2004 International Conference on Probabilistic Methods Applied to Power Systems.

[14]  M.B. Payan,et al.  A State estimation approach to harmonic polluting load characterization in distribution systems , 2005, IEEE Transactions on Power Systems.

[15]  A.B. Nassif,et al.  An investigation on the harmonic attenuation effect of modern compact fluorescent lamps , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[16]  F.S. Dos Reis,et al.  Nonlinear Loads Parameters Estimation and Modeling , 2007, 2007 IEEE International Symposium on Industrial Electronics.

[17]  J. J. Mesas,et al.  Parameter Estimation Procedure for Models of Single-Phase Uncontrolled Rectifiers , 2011, IEEE Transactions on Power Delivery.

[18]  N.R. Watson,et al.  Implications for Distribution Networks of High Penetration of Compact Fluorescent Lamps , 2009, IEEE Transactions on Power Delivery.