The accuracy of three-dimensional bladder ultrasonography in determining the residual urinary volume compared with conventional catheterisation

Abstract Objective: To determine the accuracy of three-dimensional bladder ultrasonography (US, using the BVI 3000, Verathon, WA, USA) for determining the residual urinary volume, compared with the conventional catheterisation method. Patients and methods: We conducted a cross-sectional study at day-care unit of a University hospital after obtaining approval from the Ethics Review Committee of the hospital. Thirty-four patients with lower urinary tract symptoms requiring cystometrography were included. The postvoid volume was measured by bladder US, with three readings taken, and then patient was catheterised using a 12-F Nelaton catheter to measure the urinary volume. The mean of the three readings was compared with the catheterisation volume. Results: The mean (SD) urinary volumes by US and catheterisation were 261 (186) and 260 (175) mL, respectively, and the correlation (r2) was 0.97. There was no effect of age, gender or body mass index on the accuracy of bladder US, which was accurate even when the urinary volume was ⩽100 mL. Conclusion: The bladder US estimate is as accurate as catheterisation for determining the postvoid residual urinary volume. Its accuracy was also comparable when the urinary volume is <100 mL, and there was no significant effect of age, gender and body mass index. This system could replace the more invasive catheterisation, and with excellent accuracy.

[1]  M. Koppán,et al.  Assessment of postoperative postvoid residual bladder volume using three-dimensional ultrasound volumetry. , 2011, Ultrasound in medicine & biology.

[2]  H. Drutz,et al.  The Accuracy of Portable Abdominal Ultrasound Equipment in Measuring Postvoid Residual Volume , 1999, International Urogynecology Journal.

[3]  T. Rutherford,et al.  Cystic pelvic pathology presenting as falsely elevated post-void residual urine measured by portable ultrasound bladder scanning: report of 3 cases and review of the literature. , 2000, Urology.

[4]  M. Ather,et al.  Use of residual fraction instead of residual volume in the evaluation of lower urinary tract symptoms. , 2000, Techniques in urology.

[5]  P. Ellsworth,et al.  The pitfalls of BladderScan™ PVR in evaluating bladder volume in adolescent females. , 2011, Journal of pediatric urology.

[6]  N. Simforoosh,et al.  Accuracy of residual urine measurement in men: comparison between real-time ultrasonography and catheterization. , 1997, The Journal of urology.

[7]  J. Chmiel,et al.  Urethral meatal colonization in the pathogenesis of catheter-associated bacteriuria. , 1983, The Journal of urology.

[8]  M H Ather,et al.  Uroflowmetry and evaluation of voiding disorders. , 1998, Techniques in urology.

[9]  P. Abrams,et al.  Noninvasive techniques for the measurement of isovolumetric bladder pressure. , 2004, The Journal of urology.

[10]  S L Stanton,et al.  The standardisation of terminology of lower urinary tract function , 1989, World Journal of Urology.

[11]  D. Roth,et al.  Measurement of Postvoid Residual Urine with Portable Transabdominal Bladder Ultrasound Scanner and Urethral Catheterization , 2000, International Urogynecology Journal.

[12]  H. Anton,et al.  Clinical utility of a portable ultrasound device in intermittent catheterization. , 1998, Archives of physical medicine and rehabilitation.

[13]  C. Bevan,et al.  Assessing bladder volumes in young children prior to instrumentation: accuracy of an automated ultrasound device compared to real-time ultrasound. , 2011, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[14]  Kyu-Sung Lee,et al.  Accuracy and precision of a new portable ultrasound scanner, the BME-150A, in residual urine volume measurement: a comparison with the BladderScan BVI 3000 , 2007, International Urogynecology Journal.

[15]  L. Bih,et al.  The accuracy of ultrasonic estimation of bladder volume: a comparison of portable and stationary equipment. , 2004, Archives of physical medicine and rehabilitation.

[16]  K. Ghani,et al.  Portable ultrasonography and bladder volume accuracy--a comparative study using three-dimensional ultrasonography. , 2008, Urology.

[17]  Seung-June Oh,et al.  Accuracy of post‐void residual urine volume measurement using a portable ultrasound bladder scanner with real‐time pre‐scan imaging , 2011, Neurourology and urodynamics.

[18]  P. Abrams,et al.  Bladder outlet obstruction index, bladder contractility index and bladder voiding efficiency: three simple indices to define bladder voiding function , 1999, BJU international.

[19]  Magnus Fall,et al.  The standardisation of terminology in lower urinary tract function: report from the standardisation sub-committee of the International Continence Society. , 2003, Urology.

[20]  M. Heymans,et al.  The BladderScan BVI 6200® is not accurate enough for use in a bladder retraining program. , 2013, Journal of pediatric urology.

[21]  Medical Advisory Secretariat Portable bladder ultrasound: an evidence-based analysis. , 2006, Ontario health technology assessment series.

[22]  M. Prins,et al.  Evaluation of a non-invasive bladder volume measurement in children , 2008, Scandinavian journal of urology and nephrology.

[23]  Annick Larochelle,et al.  Accuracy of bladder scanning in the assessment of postvoid residual volume. , 2009, Journal of obstetrics and gynaecology Canada : JOGC = Journal d'obstetrique et gynecologie du Canada : JOGC.