Evaluation of the possibility to use thick slabs of reconstructed outer breast tomosynthesis slice images

The large image volumes in breast tomosynthesis (BT) have led to large amounts of data and a heavy workload for breast radiologists. The number of slice images can be decreased by combining adjacent image planes (slabbing) but the decrease in depth resolution can considerably affect the detection of lesions. The aim of this work was to assess if thicker slabbing of the outer slice images (where lesions seldom are present) could be a viable alternative in order to reduce the number of slice images in BT image volumes. The suggested slabbing (an image volume with thick outer slabs and thin slices between) were evaluated in two steps. Firstly, a survey of the depth of 65 cancer lesions within the breast was performed to estimate how many lesions would be affected by outer slabs of different thicknesses. Secondly, a selection of 24 lesions was reconstructed with 2, 6 and 10 mm slab thickness to evaluate how the appearance of lesions located in the thicker slabs would be affected. The results show that few malignant breast lesions are located at a depth less than 10 mm from the surface (especially for breast thicknesses of 50 mm and above). Reconstruction of BT volumes with 6 mm slab thickness yields an image quality that is sufficient for lesion detection for a majority of the investigated cases. Together, this indicates that thicker slabbing of the outer slice images is a promising option in order to reduce the number of slice images in BT image volumes.

[1]  Serge Muller,et al.  Thick Slices from Tomosynthesis Data Sets: Phantom Study for the Evaluation of Different Algorithms , 2009, Journal of Digital Imaging.

[2]  R. L. Birdwell Digital Breast Tomosynthesis: A Pilot Observer Study , 2009 .

[3]  Thomas Mertelmeier,et al.  Optimizing High Resolution Reconstruction in Digital Breast Tomosynthesis Using Filtered Back Projection , 2014, Digital Mammography / IWDM.

[4]  Nassir Navab,et al.  Out-of-Plane Artifact Reduction in Tomosynthesis Based on Regression Modeling and Outlier Detection , 2012, Digital Mammography / IWDM.

[5]  David Gur,et al.  Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. , 2011, AJR. American journal of roentgenology.

[6]  Anders Tingberg,et al.  Performance of one-view breast tomosynthesis as a stand-alone breast cancer screening modality: results from the Malmö Breast Tomosynthesis Screening Trial, a population-based study , 2015, European Radiology.

[7]  Magnus Båth,et al.  VIEWDEX: an efficient and easy-to-use software for observer performance studies. , 2010, Radiation protection dosimetry.

[8]  A Tingberg,et al.  Breast cancer screening with tomosynthesis--initial experiences. , 2011, Radiation protection dosimetry.

[9]  Federica Zanca,et al.  Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-ray imaging observer study. , 2012, Radiology.

[10]  Nico Karssemeijer,et al.  The Effect of Slab Size on Mass Detection Performance of a Screen-Film CAD System in Reconstructed Tomosynthesis Volumes , 2010, Digital Mammography / IWDM.

[11]  David Gur,et al.  Digital breast tomosynthesis: observer performance study. , 2009, AJR. American journal of roentgenology.

[12]  Anders Tingberg,et al.  Digital mammography and tomosynthesis for breast cancer diagnosis. , 2011, Expert opinion on medical diagnostics.

[13]  Anders Tingberg,et al.  Image Quality of Thick Average Intensity Pixel Slabs Using Statistical Artifact Reduction in Breast Tomosynthesis , 2014, Digital Mammography / IWDM.

[14]  Martin Andersson,et al.  A study of the feasibility of using slabbing to reduce tomosynthesis review time , 2013, Medical Imaging.