Realization of 5-bus system using soft computing technique for flexible alternating current transmission system (FACTS) devices

Total transfer capability analysis of power system is currently a critical issue in both planning & operating of systems. These issues mainly occur due to increase in area and interchanges among utilities. To reduce the flows in heavily loaded lines, Flexible Alternating Current Transmission System (FACTS) devices is used, this results in increased transfer capability, improve stability of the network, low system losses, and fulfill contractual required by controlling the power flows in the network. To achieve parameters FACTS devices are placed optimally and is done with the help of reduction of total system reactive power loss sensitivity indices analysis method and real power flow performance index sensitivity indices analysis method. Thyristor-Control-Series-Capacitor (TCSC) is used as a FACTS device in the proposed sensitivity analysis method. To decide priority of line for placing TCSC, soft computing technique "Fuzzy logic method" is employed. The performance evaluation of proposed sensitivity analysis methods is done using electrical IEEE-5 bus system. The sensitivity indices are programmed using Matrix Laboratory.

[1]  Fuzzy Logic in Control Systems : Fuzzy Logic , 2022 .

[2]  Ji Yan-ping Application of FACTS in Power System , 2007 .

[3]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[4]  R.G. Harley,et al.  Modified Takagi-Sugeno fuzzy logic based controllers for a static compensator in a multimachine power system , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[5]  Mariesa L. Crow,et al.  STATCOM control for power system voltage control applications , 2000 .

[6]  Om P. Malik,et al.  An artificial neural network based adaptive power system stabilizer , 1993 .

[7]  M. Rajaram,et al.  India , 2019, Journal of the Neurological Sciences.

[8]  A. David,et al.  Placement of FACTS devices in open power market , 2000 .

[9]  K. K. Sen SSSC-static synchronous series compensator: theory, modeling, and application , 1998 .

[10]  Hari Om Gupta,et al.  FACTS devices location for enhancement of total transfer capability , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[11]  N. K. Sharma,et al.  A Novel Placement Strategy for FACTS Controllers , 2002, IEEE Power Engineering Review.

[12]  S. Gerbex,et al.  Optimal Location of Multi-Type FACTS Devices in a Power System by Means of Genetic Algorithms , 2001, IEEE Power Engineering Review.

[13]  Li Wang,et al.  Dynamic Stability Improvement of Four Parallel-Operated PMSG-Based Offshore Wind Turbine Generators Fed to a Power System Using a STATCOM , 2013, IEEE Transactions on Power Delivery.

[14]  S.J. Cheng,et al.  Optimal Location and Parameter Setting of TCSC by Both Genetic Algorithm and Particle Swarm Optimization , 2007, 2007 2nd IEEE Conference on Industrial Electronics and Applications.

[15]  Abouzar Samimi,et al.  A New Method for Optimal Placement of TCSC Based on Sensitivity Analysis for Congestion Management , 2012 .

[16]  N. Subrahmanyam,et al.  Soft computing based power system stabilizers , 2016, 2016 IEEE Students' Conference on Electrical, Electronics and Computer Science (SCEECS).

[17]  Peng Fei,et al.  Power quality improvement with SVC in power supply system , 2012 .