Multimodality image-guided surgery for the treatment of medically refractory epilepsy.

OBJECT The aim of this study was to review seizure outcome, imaging modalities used, and complications following surgery in patients with epilepsy who had undergone multimodality image-guided surgery at our institution. METHODS Data from patients with epilepsy who had undergone surgery between April 1999 and October 2001 were reviewed. During this time period, 116 operations were performed in 109 patients with medically refractory epilepsy. Among these patients, 22 were selected to undergo multimodality image-guided surgery primarily on the basis of whether they had no lesion visible on conventional magnetic resonance (MR) imaging sequences, multiple lesions, or one very large lesion that could not be completely resected without the risk of significant postoperative morbidity. A fourth group of patients in whom there was a single lesion in the eloquent cortex, a location associated with a significant risk of postoperative morbidity, was also included in the analysis. This latter group was assessed with the aid of intracranial grid electrodes that were coregistered to the MR image and were used intraoperatively to minimize electrode position error. Other imaging modalities used included positron emission tomography (PET), fluid-attenuated inversion recovery (FLAIR) MR imaging, and subtracted ictal-interictal single-photon positron emission computerized tomography (SPECT) coregistered with MR imaging (SISCOM). After coregistration, images were then downloaded onto an image-guided surgical system and the epileptogenic area was then resected. The mean patient age was 33 years (range 17-46 years), and there was a mean follow up of 27 months (range 14-41 months). Multimodality coregistrations used were as follows: nine PET scans, seven subdural electrode grids, four SISCOM studies, one FLAIR MR image, and one combined PET/subdural grid. Seizure outcome was excellent in 17 patients (77%) and not excellent in five (23%), or favorable in 19 (86%) and unfavorable in three (14%). Six patients (27%) had a transient neurological deficit, one patient (5%) a permanent major deficit, and three patients (15%) a permanent minor deficit. Five patients (24%) had a transient psychiatric problem postoperatively. CONCLUSIONS Multimodality image-guided surgery offers a new perspective in surgery for epilepsy. Functional imaging modalities previously lateralized and often localized a seizure focus, but did not provide enough anatomical information to resect the epileptogenic zone confidently and safely. The coregistration of these modalities to a volumetric MR image and their incorporation into an image-guided system has allowed surgeons to offer surgery to patients who may not previously have been considered eligible, with outcomes comparable to those in patients with more straightforward lesional epilepsy.

[1]  C. Nimsky,et al.  Intraoperative compensation for brain shift. , 2001, Surgical neurology.

[2]  I. Jensen,et al.  TEMPORAL LOBE EPILEPSY , 1976, Acta Neurochirurgica.

[3]  P. V. Ness Surgical outcome for neocortical (extrahippocampal) focal epilepsy , 1991 .

[4]  Xiaoping Hu,et al.  Retrospective Fusion of Radiographic and MR Data for Localization of Subdural Electrodes , 1992, Journal of computer assisted tomography.

[5]  A. Delgado-Escueta,et al.  Type I complex partial seizures of hippocampal origin , 1985, Neurology.

[6]  Terence J O'Brien,et al.  A computer-generated stereotactic "Virtual Subdural Grid" to guide resective epilepsy surgery. , 2004, AJNR. American journal of neuroradiology.

[7]  J. Mazziotta,et al.  MRI‐PET Registration with Automated Algorithm , 1993, Journal of computer assisted tomography.

[8]  W. Penfield,et al.  Results of surgical therapy for focal epileptic seizures. , 1955, Canadian Medical Association journal.

[9]  Patrick J. Kelly Stereotactic surgery: what is past is prologue. , 2000 .

[10]  J. F. Bradshaw,et al.  The principal axes transformation--a method for image registration. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  J. Spreer,et al.  Visualization of subdural strip and grid electrodes using curvilinear reformatting of 3D MR imaging data sets. , 2002, AJNR. American journal of neuroradiology.

[12]  Richard A. Robb,et al.  New approach to 3-D registration of multimodality medical images by surface matching , 1992, Other Conferences.

[13]  S. Berkovic,et al.  Temporal lobectomy for epilepsy — complicationsin 200 patients , 1995, Journal of Clinical Neuroscience.

[14]  C. Pelizzari,et al.  Accurate Three‐Dimensional Registration of CT, PET, and/or MR Images of the Brain , 1989, Journal of computer assisted tomography.

[15]  F Cendes,et al.  Diagnosis of subtle focal dysplastic lesions: Curvilinear reformatting from three‐dimensional magnetic resonance imaging , 1999, Annals of neurology.

[16]  W. Marsh,et al.  Acute postoperative seizures following anterior temporal lobectomy for intractable partial epilepsy. , 1998, Journal of neurosurgery.

[17]  J. Engel Finally, a randomized, controlled trial of epilepsy surgery. , 2001, The New England journal of medicine.

[18]  G. Jackson,et al.  Preoperative MRI predicts outcome of temporal lobectomy , 1995, Neurology.

[19]  Christian Vollmar,et al.  Usefulness of 3-D reconstructed images of the human cerebral cortex for localization of subdural electrodes in epilepsy surgery , 2000, Epilepsy Research.

[20]  M. Cook,et al.  Insertion of depth electrodes with or without subdural grids using frameless stereotactic guidance systems -- technique and outcome , 2002, British journal of neurosurgery.

[21]  M. Newton,et al.  Hippocampal Atrophy Is Not a Major Determinant of Regional Hypometabolism in Temporal Lobe Epilepsy , 1997, Epilepsia.

[22]  M. Murphy Surgical approaches to mesial temporal structures for epilepsy: a personal view , 2000, Journal of Clinical Neuroscience.

[23]  V. Lowe,et al.  Triple-technique (MR imaging, single-photon emission CT, and CT) coregistration for image-guided surgical evaluation of patients with intractable epilepsy. , 1999, AJNR. American journal of neuroradiology.

[24]  E. Benardete,et al.  Comparison of Frameless Stereotactic Systems: Accuracy, Precision, and Applications , 2001, Neurosurgery.

[25]  Geirmund Unsgaard,et al.  Neuronavigation by Intraoperative Three-dimensional Ultrasound: Initial Experience during Brain Tumor Resection , 2002, Neurosurgery.

[26]  Jerome Engel,et al.  Outcome with respect to epileptic seizures. , 1993 .

[27]  [Intracranial ECoG electrodes. Location determination using three-dimensional reconstruction of MR data of the brain as a component of the presurgical diagnosis of epilepsy]. , 1993, Der Radiologe.

[28]  David M.D. Roberts,et al.  Image-Guided Neurosurgery: Clinical Applications of Surgical Navigation , 1998 .

[29]  J. Engel,et al.  Surgery for seizures. , 1996, The New England journal of medicine.

[30]  G. Egan,et al.  Comparison of ictal SPECT and interictal PET in the presurgical evaluation of temporal lobe epilepsy , 1995, Annals of neurology.

[31]  M. Y. Wang,et al.  Measurement of Intraoperative Brain Surface Deformation Under a Craniotomy , 1998, MICCAI.

[32]  B H Brinkmann,et al.  Subtraction ictal SPET co‐registered to MRI in partial epilepsy: Description and technical validation of the method with phantom and patient studies , 1998, Nuclear medicine communications.

[33]  Duchowny Indications and criteria for surgical intervention , 1997 .

[34]  S. Hassenbusch,et al.  Brain tumor resection aided with markers placed using stereotaxis guided by magnetic resonance imaging and computed tomography. , 1991, Neurosurgery.

[35]  Gene H. Barnett,et al.  Astrocytoma resection using an interactive frameless stereotactic wand: an early experience , 1994, Journal of Clinical Neuroscience.

[36]  G H Barnett,et al.  Intraoperative localization using an armless, frameless stereotactic wand. Technical note. , 1993, Journal of neurosurgery.

[37]  Mark J. Cook,et al.  Multimodality image-guided epilepsy surgery , 2001, Journal of Clinical Neuroscience.

[38]  J. Mazziotta,et al.  Hippocampal neuronal loss and regional hypometabolism in temporal lobe epilepsy , 1994, Annals of neurology.

[39]  T. Greitz,et al.  Head fixation device for reproducible position alignment in transmission CT and positron emission tomography. , 1981, Journal of computer assisted tomography.

[40]  G Cascino,et al.  Surgically remediable lesional syndromes (chapter 7) , 1993 .

[41]  M. Cook,et al.  Accuracy of coregistration of single-photon emission CT with MR via a brain surface matching technique. , 1996, AJNR. American journal of neuroradiology.

[42]  E. So Classifications and epidemiologic considerations of epileptic seizures and epilepsy. , 1995, Neuroimaging clinics of North America.

[43]  R. Kuzniecky,et al.  Predictive value of magnetic resonance imaging in temporal lobe epilepsy surgery. , 1993, Archives of neurology.

[44]  J. Mazziotta,et al.  Rapid Automated Algorithm for Aligning and Reslicing PET Images , 1992, Journal of computer assisted tomography.

[45]  P. Black,et al.  Stereotactic craniotomy: methods and results using the Brown-Roberts-Wells stereotactic frame. , 1989, Neurosurgery.

[46]  W. Hauser,et al.  Epilepsy: Frequency Causes and Consequences , 1990 .

[47]  E. Cavalheiro,et al.  Multiple Pilocarpine‐Induced Status Epilepticus in Developing Rats: A Long‐Term Behavioral and Electrophysiological Study , 2000, Epilepsia.

[48]  Michael Murphy,et al.  Non-invasive investigations successfully select patients for temporal lobe surgery , 1997, Journal of neurology, neurosurgery, and psychiatry.

[49]  A. Jödicke,et al.  Intraoperative three-dimensional ultrasonography: an approach to register brain shift using multidimensional image processing. , 1998, Minimally invasive neurosurgery : MIN.

[50]  R. Kikinis,et al.  Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. , 1997, Neurosurgery.

[51]  Michael Channing,et al.  {18F}fluorodeoxyglucose positron emission tomography in refractory complex partial seizures , 1983, Annals of neurology.

[52]  K. Smith,et al.  The NeuroStation--a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[53]  W. Pilcher,et al.  Complications of epilepsy surgery. , 1993, Neurosurgery clinics of North America.