Outcome prediction of emergency patients by noninvasive hemodynamic monitoring.

OBJECTIVES We used noninvasive hemodynamic monitoring in the initial resuscitation beginning in the emergency department (ED) for the following reasons: (1) to describe early survivor and nonsurvivor patterns of emergency patients in terms of cardiac, pulmonary, and tissue perfusion deficiencies; (2) to measure quantitatively the net cumulative amount of deficit or excess of the monitored functions that correlate with survival or death; and (3) to explore the use of discriminant analysis to predict outcome and evaluate the biological significance of monitored deficits. METHODS This is a descriptive study of the feasibility of noninvasive monitoring of patients with acute emergency conditions in the ED to evaluate and quantify hemodynamic deficits as early as possible. The noninvasive monitoring systems consisted of a bioimpedance method for estimating cardiac output together with pulse oximetry to reflect pulmonary function, transcutaneous oxygen tension to reflect tissue perfusion, and BP to reflect the overall circulatory status. These continuously monitored noninvasive measurements were used to prospectively evaluate circulatory patterns in 151 consecutively monitored severely injured patients beginning with admission to the ED in a university-run county hospital. The net cumulative deficit or excess of each monitored parameter was calculated as the cumulative difference from the normal value vs the time-integrated monitored curve for each patient. The deficits of cardiac, pulmonary, and tissue perfusion functions were analyzed in relation to outcome by discriminant analysis and were cross-validated. RESULTS The mean (+/- SEM) net cumulative excesses (+) or deficits (-) from normal in surviving vs nonsurviving patients, respectively, were as follows: cardiac index (CI), +81 +/- 52 vs -232 +/- 138 L/m(2) (p = 0.037); arterial hemoglobin saturation, -1 +/- 0.3 vs -8 +/- 2.6%/h (p = 0.006); and tissue perfusion, +313 +/- 88 vs -793 +/- 175, mm Hg/h (p = 0.001). The cumulative mean arterial BP deficit for survivors was -10 +/- 13 mm Hg/h, and for nonsurvivors it was -57 +/- 24 mm Hg/h (p = 0.078). CONCLUSIONS Noninvasive monitoring systems provided continuously monitored on-line displays of data in the early postadmission period from the ED to the operating room and to the ICU for early recognition of circulatory dysfunction in short-term emergency conditions. Survival was predicted by discriminant analysis models based on the quantitative assessment of the net cumulative deficits of CI, arterial hypoxemia, and tissue perfusion, which were significantly greater in the nonsurvivors.

[1]  C. Hinds,et al.  Response of critically ill patients to treatment aimed at achieving supranormal oxygen delivery and consumption. Relationship to outcome. , 1993, Chest.

[2]  M. Lamy,et al.  The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination. , 1994, American journal of respiratory and critical care medicine.

[3]  M. Levy,et al.  Frequency of mortality and myocardial infarction during maximizing oxygen delivery: a prospective, randomized trial. , 1995, Critical care medicine.

[4]  H Belzberg,et al.  Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients. , 1998, Chest.

[5]  K. Tremper,et al.  Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock , 1981, Critical care medicine.

[6]  W. Shoemaker,et al.  Hemodynamic and oxygen transport responses in survivors and nonsurvivors of high‐risk surgery , 1993, Critical care medicine.

[7]  E. Moore,et al.  Incommensurate oxygen consumption in response to maximal oxygen availability predicts postinjury multiple organ failure. , 1991, Journal of Trauma.

[8]  Hun H. Sun,et al.  Hemodynamic monitoring by impedance cardiography with an improved signal processing technique , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[9]  C. Polachini,et al.  Effects of maximizing oxygen delivery on morbidity and mortality in high-risk surgical patients , 2000, Critical care medicine.

[10]  D. Lubbers,et al.  Theoretical basis of the transcutaneous blood gas measurements. , 1981 .

[11]  E. Bennett,et al.  A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. , 1993, JAMA.

[12]  G R Bernard,et al.  The American-European Consensus Conference on ARDS, part 2: Ventilatory, pharmacologic, supportive therapy, study design strategies, and issues related to recovery and remodeling. Acute respiratory distress syndrome. , 1998, American journal of respiratory and critical care medicine.

[13]  K. Tremper,et al.  Effects of hypoxia and shock on transcutaneous Po2 values in dogs , 1979, Critical care medicine.

[14]  I. Woods,et al.  Reducing the risk of major elective surgery: randomised controlled trial of preoperative optimisation of oxygen delivery , 1999, BMJ.

[15]  W. Shoemaker,et al.  Reliability of clinical monitoring to assess blood volume in critically ill patients. , 1982 .

[16]  C. Hinds,et al.  Elevation of systemic oxygen delivery in the treatment of critically ill patients. , 1994, The New England journal of medicine.

[17]  W. Shoemaker,et al.  Relationship between supranormal circulatory values, time delays, and outcome in severely traumatized patients , 1993, Critical care medicine.

[18]  H. Engel,et al.  Evaluation of prognostic indices based on hemodynamic and oxygen transport variables in shock patients with adult respiratory distress syndrome , 1987, Critical care medicine.

[19]  P. Pelosi,et al.  A Trial of Goal-Oriented Hemodynamic Therapy in Critically Ill Patients , 1995 .

[20]  W. Shoemaker,et al.  Sequential cardiorespiratory patterns associated with outcome in septic shock. , 1984, Chest.

[21]  T. Scalea,et al.  Geriatric blunt multiple trauma: improved survival with early invasive monitoring. , 1988, The Journal of trauma.

[22]  E. Rackow,et al.  Elevation of cardiac output and oxygen delivery improves outcome in septic shock. , 1992, Chest.

[23]  C. Sprung,et al.  Pulmonary Artery Catheter Consensus conference: consensus statement. , 1997, Critical care medicine.

[24]  W. Shoemaker,et al.  Prospective, randomized trial of survivor values of cardiac index, oxygen delivery, and oxygen consumption as resuscitation endpoints in severe trauma. , 1995, The Journal of trauma.

[25]  M. Rowe,et al.  Transcutaneous oxygen monitoring in shock and resuscitation. , 1979, Journal of pediatric surgery.

[26]  J. Calvin,et al.  Pulmonary Artery Catheter Consensus Conference: the first step. , 1997, Critical care medicine.

[27]  F. Cerra,et al.  Preoperative optimization of cardiovascular hemodynamics improves outcome in peripheral vascular surgery. A prospective, randomized clinical trial. , 1991, Annals of surgery.

[28]  Philip Smith,et al.  Effect of maximizing oxygen delivery on morbidity and mortality rates in critically ill patients: A prospective, randomized, controlled study , 1993, Critical care medicine.

[29]  U. Goldbourt,et al.  Use of pulmonary artery catheters in patients with acute myocardial infarction. Analysis of experience in 5,841 patients in the SPRINT Registry. SPRINT Study Group. , 1990, Chest.

[30]  K. Tremper,et al.  Continuous transcutaneous oxygen monitoring during respiratory failure, cardiac decompensation, cardiac arrest, and CPR: Transcutaneous oxygen monitoring during arrest and CPR , 1980, Critical care medicine.

[31]  O. Boyd,et al.  The oxygen trail: the goal. , 1999, British medical bulletin.

[32]  W. Shoemaker,et al.  Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. , 1988, Chest.

[33]  W. Shoemaker,et al.  Role of oxygen debt in the development of organ failure sepsis, and death in high-risk surgical patients. , 1992, Chest.

[34]  K. Tremper,et al.  Dermal Heat Transport Analysis for Transcutaneous O2 Measurement , 1978, Acta anaesthesiologica Scandinavica. Supplementum.

[35]  W. Shoemaker,et al.  Early physiologic patterns in acute illness and accidents: toward a concept of circulatory dysfunction and shock based on invasive and noninvasive hemodynamic monitoring. , 1996, New horizons.

[36]  L. Goldman,et al.  The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. , 1996, JAMA.

[37]  J. Edwards,et al.  Hemodynamic and oxygen transport variables in cardiogenic shock secondary to acute myocardial infarction, and response to treatment. , 1990, The American journal of cardiology.