Development of passive submillimeter-wave video imaging systems

Passive submillimeter wave imaging is a concept that has been in the focus of interest as a promising technology for security applications for a number of years. It utilizes the unique optical properties of submillimeter waves and promises an alternative to millimeter-wave and X-ray backscattering portals for personal security screening in particular. Possible application scenarios demand sensitive, fast, and fleixible high-quality imaging techniques. Considering the low radiometric contrast of indoor scenes in the submillimeter range, this objective calls for an extremely high detector sensitivity that can only be achieved using cooled detectors. Our approach to this task is a series of passives standoff video cameras for the 350 GHz band that represent an evolving concept and a continuous development since 2007. The cameras utilize arrays of superconducting transition-edge sensors (TES), i.e. cryogenic microbolometers, as radiation detectors. The TES are operate at temperatures below 1K, cooled by a closed-cycle cooling system, and coupled to superconducting readout electronics. By this means, background limited photometry (BLIP) mode is achieved providing the maximum possible signal to noise ratio. At video rates, this leads to a pixel NETD well below 1K. The imaging system is completed by reflector optics based on free-form mirrors. For object distances of 3–10m, a field of view up to 2m height and a diffraction-limited spatial resolution in the order of 1–2cm is provided. Opto-mechanical scanning systems are part of the optical setup and capable frame rates up to 25 frames per second. Both spiraliform and linear scanning schemes have been developed.

[1]  A. Tamminen,et al.  Indirect holographic imaging: evaluation of image quality at 310 GHz , 2010, Defense + Commercial Sensing.

[2]  Christopher J. Mann First demonstration of a vehicle mounted 250GHz real time passive imager , 2009, Defense + Commercial Sensing.

[3]  Patrick Lj Valdez,et al.  Standoff concealed weapon detection using a 350-GHz radar imaging system , 2010, Defense + Commercial Sensing.

[4]  J. Zmuidzinas Thermal noise and correlations in photon detection. , 2003, Applied optics.

[5]  Erik Heinz,et al.  Time-domain multiplexed SQUID readout of a bolometer camera for APEX , 2011 .

[6]  Erik Heinz,et al.  Passive Submillimeter-wave Stand-off Video Camera for Security Applications , 2010 .

[7]  Erik Heinz,et al.  Next generation of a sub-millimetre wave security camera utilising superconducting detectors , 2013 .

[8]  J. Bock,et al.  Relative performance of filled and feedhorn-coupled focal-plane architectures. , 2002, Applied optics.

[9]  Peter H. Siegel,et al.  An Approach for Sub-Second Imaging of Concealed Objects Using Terahertz (THz) Radar , 2009 .

[10]  Elliott R. Brown,et al.  Fundamentals of Terrestrial Millimeter-Wave and THz Remote Sensing , 2003 .

[11]  H.B. Wallace,et al.  Standoff Detection of Weapons and Contraband in the 100 GHz to 1 THz Region , 2007, IEEE Transactions on Antennas and Propagation.

[12]  W B Lewis,et al.  Fluctuations in streams of thermal radiation , 1947 .

[13]  H. Meyer,et al.  Superconducting bolometer array with SQUID readout for submillimetre wavelength detection , 2003 .

[14]  Torsten May,et al.  Safe VISITOR: visible, infrared, and terahertz object recognition for security screening application , 2009, Defense + Commercial Sensing.

[15]  Erich N. Grossman,et al.  Passive hyperspectral terahertz imagery for security screening using a cryogenic microbolometer , 2005, SPIE Defense + Commercial Sensing.

[16]  Duncan A. Robertson,et al.  340-GHz 3D radar imaging test bed with 10-Hz frame rate , 2012, Defense + Commercial Sensing.

[17]  Erik Heinz,et al.  Dynamic behavior of dc SQUIDs in time-division multiplexing readout schemes , 2013 .

[18]  Torsten May,et al.  A superconducting terahertz imager , 2007, SPIE Defense + Commercial Sensing.

[19]  D. Hodges,et al.  Far infrared imagery. , 1976, Applied optics.

[20]  P. Richards Bolometers for infrared and millimeter waves , 1994 .

[21]  S. Alekseev,et al.  Human skin permittivity determined by millimeter wave reflection measurements , 2007, Bioelectromagnetics.

[22]  W. B. Doriese,et al.  Electrical and optical measurements on the first SCUBA-2 prototype 1280 pixel submillimeter superconducting bolometer array. , 2007, The Review of scientific instruments.

[23]  K. Irwin,et al.  Superconducting multiplexer for arrays of transition edge sensors , 1999 .

[24]  Erik Heinz,et al.  Toward high-sensitivity and high-resolution submillimeter-wave video imaging , 2011 .

[25]  Peter A. R. Ade,et al.  A 350-GHz high-resolution high-sensitivity passive video imaging system , 2010, Defense + Commercial Sensing.