Development of passive submillimeter-wave video imaging systems
暂无分享,去创建一个
Erik Heinz | Hans-Georg Meyer | Gabriel Zieger | Solveig Anders | André Krüger | Marco Schulz | Detlef Born | Katja Peiselt | Torsten May | Anika Brömel | Vyacheslav Zakosarenko | Torsten Krause | H. Meyer | T. May | E. Heinz | S. Anders | V. Zakosarenko | G. Zieger | D. Born | A. Krüger | K. Peiselt | A. Brömel | M. Schulz | Torsten Krause
[1] A. Tamminen,et al. Indirect holographic imaging: evaluation of image quality at 310 GHz , 2010, Defense + Commercial Sensing.
[2] Christopher J. Mann. First demonstration of a vehicle mounted 250GHz real time passive imager , 2009, Defense + Commercial Sensing.
[3] Patrick Lj Valdez,et al. Standoff concealed weapon detection using a 350-GHz radar imaging system , 2010, Defense + Commercial Sensing.
[4] J. Zmuidzinas. Thermal noise and correlations in photon detection. , 2003, Applied optics.
[5] Erik Heinz,et al. Time-domain multiplexed SQUID readout of a bolometer camera for APEX , 2011 .
[6] Erik Heinz,et al. Passive Submillimeter-wave Stand-off Video Camera for Security Applications , 2010 .
[7] Erik Heinz,et al. Next generation of a sub-millimetre wave security camera utilising superconducting detectors , 2013 .
[8] J. Bock,et al. Relative performance of filled and feedhorn-coupled focal-plane architectures. , 2002, Applied optics.
[9] Peter H. Siegel,et al. An Approach for Sub-Second Imaging of Concealed Objects Using Terahertz (THz) Radar , 2009 .
[10] Elliott R. Brown,et al. Fundamentals of Terrestrial Millimeter-Wave and THz Remote Sensing , 2003 .
[11] H.B. Wallace,et al. Standoff Detection of Weapons and Contraband in the 100 GHz to 1 THz Region , 2007, IEEE Transactions on Antennas and Propagation.
[12] W B Lewis,et al. Fluctuations in streams of thermal radiation , 1947 .
[13] H. Meyer,et al. Superconducting bolometer array with SQUID readout for submillimetre wavelength detection , 2003 .
[14] Torsten May,et al. Safe VISITOR: visible, infrared, and terahertz object recognition for security screening application , 2009, Defense + Commercial Sensing.
[15] Erich N. Grossman,et al. Passive hyperspectral terahertz imagery for security screening using a cryogenic microbolometer , 2005, SPIE Defense + Commercial Sensing.
[16] Duncan A. Robertson,et al. 340-GHz 3D radar imaging test bed with 10-Hz frame rate , 2012, Defense + Commercial Sensing.
[17] Erik Heinz,et al. Dynamic behavior of dc SQUIDs in time-division multiplexing readout schemes , 2013 .
[18] Torsten May,et al. A superconducting terahertz imager , 2007, SPIE Defense + Commercial Sensing.
[19] D. Hodges,et al. Far infrared imagery. , 1976, Applied optics.
[20] P. Richards. Bolometers for infrared and millimeter waves , 1994 .
[21] S. Alekseev,et al. Human skin permittivity determined by millimeter wave reflection measurements , 2007, Bioelectromagnetics.
[22] W. B. Doriese,et al. Electrical and optical measurements on the first SCUBA-2 prototype 1280 pixel submillimeter superconducting bolometer array. , 2007, The Review of scientific instruments.
[23] K. Irwin,et al. Superconducting multiplexer for arrays of transition edge sensors , 1999 .
[24] Erik Heinz,et al. Toward high-sensitivity and high-resolution submillimeter-wave video imaging , 2011 .
[25] Peter A. R. Ade,et al. A 350-GHz high-resolution high-sensitivity passive video imaging system , 2010, Defense + Commercial Sensing.