Deblurring for non‐2D fourier transform magnetic resonance imaging

For several non‐2D Fourier transform imaging methods, off‐resonant reconstruction does not just cause geometric distortion, but changes the shape of the point spread function and causes blurring. This effect is well known for projection reconstruction and spiral k‐space scanning sequences. We introduce here a method that automatically removes blur introduced by magnetic field inhomogeneity and susceptibility without using a resonant frequency map, making these imaging methods more useful. In this method, the raw data are modulated to several different frequencies and reconstructed to create a series of base images. Determination of degree of blur is done by calculating a focusing measure for each point in each base image and a composite image is then constructed using only the unblurred regions from each base image. This method has been successfully applied to phantom and in vivo images using projection‐reconstruction and spiral‐scan sequences. © 1992 Academic Press, Inc.

[1]  P. Lauterbur,et al.  Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.

[2]  C D Orth,et al.  Sharpening Stellar Images , 1978, Science.

[3]  G H Glover,et al.  Lung parenchyma: magnetic susceptibility in MR imaging. , 1991, Radiology.

[4]  W. Edelstein,et al.  Spin warp NMR imaging and applications to human whole-body imaging. , 1980, Physics in medicine and biology.

[5]  R. Muller,et al.  Real-time correction of atmospherically degraded telescope images through image sharpening , 1974 .

[6]  J. Pauly,et al.  Simultaneous spatial and spectral selective excitation , 1990, Magnetic resonance in medicine.

[7]  Kentaro Hanma,et al.  Novel Technologies for Automatic Focusing and White Balancing of Solid State Color Video Camera , 1983, IEEE Transactions on Consumer Electronics.

[8]  H. W. Park,et al.  Fast gradient‐echo chemical‐shift imaging , 1988, Magnetic resonance in medicine.

[9]  K. Sekihara,et al.  NMR Imaging for Magnets with Large Nonuniformities , 1985, IEEE Transactions on Medical Imaging.

[10]  Henry Stark,et al.  Spiral Sampling in Magnetic Resonance Imaging-The Effect of Inhomogeneities , 1987, IEEE Transactions on Medical Imaging.

[11]  R. Bracewell The Fourier Transform and Its Applications , 1966 .

[12]  S.W. Smith,et al.  Experimental results with a real-time adaptive ultrasonic imaging system for viewing through distorting media , 1990, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  A. Maeda,et al.  Reconstruction by weighted correlation for MRI with time-varying gradients. , 1988, IEEE transactions on medical imaging.

[14]  W. Perman,et al.  Improved detectability in low signal-to-noise ratio magnetic resonance images by means of a phase-corrected real reconstruction. , 1989, Medical physics.

[15]  Hiroyuki Harada,et al.  New Automatic Focusing System for Video Cameras , 1986, IEEE Transactions on Consumer Electronics.

[16]  J M Pauly,et al.  Lung parenchyma: projection reconstruction MR imaging. , 1991, Radiology.

[17]  Gregg E. Trahey,et al.  Quality factors for phase-aberration correction in medical ultrasound , 1990, Medical Imaging.

[18]  Albert Macovski,et al.  Inhomogeneity and Multiple Dimension Considerations in Magnetic Resonance Imaging with Time-Varying Gradients , 1985, IEEE Transactions on Medical Imaging.

[19]  P Webb,et al.  Rapid, fully automatic, arbitrary‐volume in vivo shimming , 1991, Magnetic resonance in medicine.

[20]  R E Sepponen A method for imaging of chemical shift or magnetic field distributions. , 1985, Magnetic resonance imaging.

[21]  M. O’Donnell,et al.  NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. , 1985, Medical physics.

[22]  C. Ahn,et al.  High-Speed Spiral-Scan Echo Planar NMR Imaging-I , 1986, IEEE Transactions on Medical Imaging.

[23]  G. Glover,et al.  Rapid in vivo proton shimming , 1991, Magnetic resonance in medicine.

[24]  Stephen J. Norton,et al.  Fast Magnetic Resonance Imaging with Simultaneously Oscillating and Rotating Fiell Gradients , 1987, IEEE Transactions on Medical Imaging.