Development and characterization of a vitreous mimicking material for radiation force imaging

In many medical ultrasound applications tissue-mimicking phantoms are of fundamental importance for the performance of controlled experiments. Traditionally, such phantoms have been constructed using gelatin and agar gels. Although the use of these materials has become standard, few alternative materials have not been fully explored. In this paper, we present a protocol developed in our laboratory that reliably produces very soft, acrylamide-based phantoms that can mimic both acoustical and mechanical characteristics of the vitreous body of the eye. Following the described protocol, a series of phantoms were constructed ranging in acrylamide concentration from 1.60% to 1.70%. Measurements across the series yielded attenuation coefficients of 0.067-0.140 dB/cm/MHz, depending on acrylamide concentration. Speed of sound ranged between 1499 and 1510 m/s, also depending on acrylamide concentration. Published values for the vitreous gel indicate an attenuation of 0.10 dB/cm/MHz and a speed of sound of 1510 m/s, making our phantoms an excellent analog of this tissue. One application of these acrylamide phantoms is to test the efficacy of the Kinetic Acoustic Vitreoretinal Examination (KAVE), a tool developed in our laboratory with the potential to aid in the diagnosis of vitreoretinal disorders. KAVE utilizes acoustic radiation force to generate small, localized displacements within the vitreous-mimicking gel. These localized displacements are quantified to yield maximum displacement, relative elasticity, and relative viscosity images. We present KAVE images of a set of four phantoms with different gel concentrations. Although B-mode and relative viscosity images exhibit no significant differences, maximum displacement, and relative elasticity images clearly differentiate gels of different concentrations. Maximum displacements ranged between 30 and 5 microns, depending on acrylamide concentration. The results presented in this paper show that soft gel phantoms can be produced in a range of elasticities not previously reported, and that these phantoms are useful for testing ultrasound instruments designed for evaluation of the vitreous gel. Furthermore, the use of acrylamide-based gels may also offer a valuable and attractive alternative for many other ultrasound applications.

[1]  M. O’Donnell,et al.  Internal displacement and strain imaging using ultrasonic speckle tracking , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  Cynthia A. Toth,et al.  Application of acoustic radiation force in ophthalmic ultrasound , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[3]  J M Thijssen,et al.  Acoustic velocity and attenuation of eye tissues at 20 MHz. , 1994, Ultrasound in medicine & biology.

[4]  R. Zimmerman In vivo measurements of the viscoelasticity of the human vitreous humor. , 1980, Biophysical journal.

[5]  F. Dunn,et al.  Compilation of empirical ultrasonic properties of mammalian tissues. II. , 1980, The Journal of the Acoustical Society of America.

[6]  R. Young,et al.  Introduction to Polymers , 1983 .

[7]  D. Sullivan Biological engineering. , 1981, Thought.

[8]  J. Susan Milton,et al.  Introduction to Probability and Statistics: Principles and Applications for Engineering and the Computing Sciences , 1990 .

[9]  T. Krouskop,et al.  Phantom materials for elastography , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  A. R. Selfridge,et al.  Approximate Material Properties in Isotropic Materials , 1985, IEEE Transactions on Sonics and Ultrasonics.

[11]  K. Parker,et al.  Sono-Elasticity: Medical Elasticity Images Derived from Ultrasound Signals in Mechanically Vibrated Targets , 1988 .

[12]  A. Manduca,et al.  Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. , 1995, Science.

[13]  W F Walker,et al.  A method of imaging viscoelastic parameters with acoustic radiation force. , 2000, Physics in medicine and biology.

[14]  W. Walker,et al.  Real-time imaging of tissue vibration using a two-dimensional speckle tracking system , 1993 .

[15]  J F Greenleaf,et al.  Vibro-acoustography: an imaging modality based on ultrasound-stimulated acoustic emission. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[16]  S. Emelianov,et al.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. , 1998, Ultrasound in medicine & biology.

[17]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[18]  J. Sebag The Vitreous , 1989, Springer New York.

[19]  E L Madsen,et al.  Oil-in-gelatin dispersions for use as ultrasonically tissue-mimicking materials. , 1982, Ultrasound in medicine & biology.

[20]  William F. Walker,et al.  Comparison of time delay estimators in medical ultrasound , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).