Efficient non-negative constrained model-based inversion in optoacoustic tomography

The inversion accuracy in optoacoustic tomography depends on a number of parameters, including the number of detectors employed, discrete sampling issues or imperfectness of the forward model. These parameters result in ambiguities on the reconstructed image. A common ambiguity is the appearance of negative values, which have no physical meaning since optical absorption can only be higher or equal than zero. We investigate herein algorithms that impose non-negative constraints in model-based optoacoustic inversion. Several state-of-the-art non-negative constrained algorithms are analyzed. Furthermore, an algorithm based on the conjugate gradient method is introduced in this work. We are particularly interested in investigating whether positive restrictions lead to accurate solutions or drive the appearance of errors and artifacts. It is shown that the computational performance of non-negative constrained inversion is higher for the introduced algorithm than for the other algorithms, while yielding equivalent results. The experimental performance of this inversion procedure is then tested in phantoms and small animals, showing an improvement in image quality and quantitativeness with respect to the unconstrained approach. The study performed validates the use of non-negative constraints for improving image accuracy compared to unconstrained methods, while maintaining computational efficiency.

[1]  Vasilis Ntziachristos,et al.  Accurate Model-Based Reconstruction Algorithm for Three-Dimensional Optoacoustic Tomography , 2012, IEEE Transactions on Medical Imaging.

[2]  Vasilis Ntziachristos,et al.  Artefact reduction in optoacoustic tomographic imaging by estimating the distribution of acoustic scatterers , 2012, Journal of biomedical optics.

[3]  E. Polak,et al.  Note sur la convergence de méthodes de directions conjuguées , 1969 .

[4]  Fabiana Zama,et al.  An iterative method for linear discrete ill-posed problems with box constraints , 2007 .

[5]  Junjie Yao,et al.  Sensitivity of photoacoustic microscopy , 2014, Photoacoustics.

[6]  Vasilis Ntziachristos,et al.  Fast Semi-Analytical Model-Based Acoustic Inversion for Quantitative Optoacoustic Tomography , 2010, IEEE Transactions on Medical Imaging.

[7]  Vasilis Ntziachristos,et al.  Model-based optoacoustic inversion with arbitrary-shape detectors. , 2011, Medical physics.

[8]  S. Jacques,et al.  Iterative reconstruction algorithm for optoacoustic imaging. , 2002, The Journal of the Acoustical Society of America.

[9]  P. Beard Biomedical photoacoustic imaging , 2011, Interface Focus.

[10]  Mark A. Anastasio,et al.  Investigation of the far-field approximation for modeling a transducer's spatial impulse response in photoacoustic computed tomography , 2013, Photoacoustics.

[11]  Robert Nuster,et al.  Photoacoustic section imaging using an elliptical acoustic mirror and optical detection. , 2012, Journal of biomedical optics.

[12]  M. Anastasio,et al.  Investigation of iterative image reconstruction in three-dimensional optoacoustic tomography , 2012, Physics in medicine and biology.

[13]  Minghua Xu,et al.  Erratum: Universal back-projection algorithm for photoacoustic computed tomography [Phys. Rev. E 71, 016706 (2005)] , 2007 .

[14]  Xin Cai,et al.  Quantitative analysis of the fate of gold nanocages in vitro and in vivo after uptake by U87-MG tumor cells. , 2013, Angewandte Chemie.

[15]  Pinhas Ephrat,et al.  Three-dimensional photoacoustic imaging by sparse-array detection and iterative image reconstruction. , 2008, Journal of biomedical optics.

[16]  Vasilis Ntziachristos,et al.  Weighted model-based optoacoustic reconstruction in acoustic scattering media. , 2013, Physics in medicine and biology.

[17]  V Ntziachristos,et al.  Three-dimensional optoacoustic tomography at video rate. , 2012, Optics express.

[18]  Lihong V. Wang,et al.  Small-Animal Whole-Body Photoacoustic Tomography: A Review , 2014, IEEE Transactions on Biomedical Engineering.

[19]  Jan Laufer,et al.  Three-dimensional noninvasive imaging of the vasculature in the mouse brain using a high resolution photoacoustic scanner. , 2009, Applied optics.

[20]  Daniel Razansky,et al.  Volumetric Real-Time Tracking of Peripheral Human Vasculature With GPU-Accelerated Three-Dimensional Optoacoustic Tomography , 2013, IEEE Transactions on Medical Imaging.

[21]  Xosé Luís Deán-Ben,et al.  Functional optoacoustic human angiography with handheld video rate three dimensional scanner☆ , 2013, Photoacoustics.

[22]  Mark A. Anastasio,et al.  Full-Wave Iterative Image Reconstruction in Photoacoustic Tomography With Acoustically Inhomogeneous Media , 2013, IEEE Transactions on Medical Imaging.

[23]  Richard Su,et al.  Whole-body three-dimensional optoacoustic tomography system for small animals. , 2009, Journal of biomedical optics.

[24]  V. Ntziachristos,et al.  Model-based optoacoustic inversions with incomplete projection data. , 2011, Medical physics.

[25]  Vasilis Ntziachristos,et al.  Volumetric real-time multispectral optoacoustic tomography of biomarkers , 2011, Nature Protocols.

[26]  Inderjit S. Dhillon,et al.  Tackling Box-Constrained Optimization via a New Projected Quasi-Newton Approach , 2010, SIAM J. Sci. Comput..

[27]  Vasilis Ntziachristos,et al.  Modeling the shape of cylindrically focused transducers in three-dimensional optoacoustic tomography , 2013, Journal of biomedical optics.

[28]  Daniel Razansky,et al.  Real-time optoacoustic brain microscopy with hybrid optical and acoustic resolution , 2014 .

[29]  Lihong V. Wang,et al.  Whole-body ring-shaped confocal photoacoustic computed tomography of small animals in vivo. , 2012, Journal of biomedical optics.

[30]  Vasilis Ntziachristos,et al.  Non-invasive whole-body imaging of adult zebrafish with optoacoustic tomography , 2012, Physics in medicine and biology.

[31]  Vasilis Ntziachristos,et al.  Acceleration of Optoacoustic Model-Based Reconstruction Using Angular Image Discretization , 2012, IEEE Transactions on Medical Imaging.

[32]  C. M. Reeves,et al.  Function minimization by conjugate gradients , 1964, Comput. J..

[33]  Lihong V. Wang,et al.  Photoacoustic computed tomography correcting for heterogeneity and attenuation. , 2012, Journal of biomedical optics.

[34]  Thomas F. Coleman,et al.  A Reflective Newton Method for Minimizing a Quadratic Function Subject to Bounds on Some of the Variables , 1992, SIAM J. Optim..

[35]  Charles L. Lawson,et al.  Solving least squares problems , 1976, Classics in applied mathematics.

[36]  V Ntziachristos,et al.  Optoacoustic methods for frequency calibration of ultrasonic sensors , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[37]  R. Bro,et al.  A fast non‐negativity‐constrained least squares algorithm , 1997 .

[38]  Junjie Yao,et al.  Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo , 2013, NeuroImage.

[39]  Jorge Nocedal,et al.  A Limited Memory Algorithm for Bound Constrained Optimization , 1995, SIAM J. Sci. Comput..

[40]  Vasilis Ntziachristos,et al.  Optical imaging of cancer heterogeneity with multispectral optoacoustic tomography. , 2012, Radiology.

[41]  Lihong V. Wang,et al.  Universal back-projection algorithm for photoacoustic computed tomography. , 2005 .

[42]  D. Bertsekas On the Goldstein-Levitin-Polyak gradient projection method , 1974, CDC 1974.