Effects of temporal modelling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections

Artefacts can result when reconstructing a dynamic image sequence from inconsistent single photon emission computed tomography (SPECT) projection data acquired by a slowly rotating gantry. The artefacts can lead to biases in kinetic parameters estimated from time-activity curves generated by overlaying volumes of interest on the images. Insufficient sampling and truncation of projections by cone-beam collimators can cause additional artefacts. To overcome these sources of bias in conventional image based dynamic data analysis, we have been investigating the estimation of time-activity curves and kinetic model parameters directly from dynamic SPECT projection data by modelling the spatial and temporal distribution of the radiopharmaceutical throughout the projected field of view. In the present work, we perform Monte Carlo simulations to study the effects of the temporal modelling on the statistical variability of the reconstructed spatiotemporal distributions. The simulations utilize fast methods for fully four-dimensional (4D) direct estimation of spatiotemporal distributions and their statistical uncertainties, using a spatial segmentation and temporal B-splines. The simulation results suggest that there is benefit in modelling higher orders of temporal spline continuity. In addition, the accuracy of the time modelling can be increased substantially without unduly increasing the statistical uncertainty, by using relatively fine initial time sampling to capture rapidly changing activity distributions.

[1]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[2]  B. Mazoyer,et al.  Kinetic data analysis with a noisy input function. , 1987, Physics in medicine and biology.

[3]  J. Terry,et al.  Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction , 1990 .

[4]  A. Nunn,et al.  Absorbed radiation dose to humans from technetium-99m-teboroxime. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  Andreas Robert Formiconi,et al.  Least squares algorithm for region-of-interest evaluation in emission tomography , 1993, IEEE Trans. Medical Imaging.

[6]  B M Tsui,et al.  Evaluation of cardiac cone-beam single photon emission computed tomography using observer performance experiments and receiver operating characteristic analysis. , 1993, Investigative radiology.

[7]  G. Zeng,et al.  Kinetic parameter estimation from SPECT cone-beam projection measurements. , 1998, Physics in medicine and biology.

[8]  E. DiBella,et al.  Analytical propagation of errors in dynamic SPECT: estimators, degrading factors, bias and noise. , 1999, Physics in medicine and biology.

[9]  A. Celler,et al.  The incorporation of organ uptake into dynamic SPECT (dSPECT) image reconstruction , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[10]  Jonathan S. Maltz Optimal time-activity basis selection for exponential spectral analysis: application to the solution of large dynamic emission tomographic reconstruction problems , 2000 .

[11]  R. Huesman,et al.  Direct least-squares estimation of spatiotemporal distributions from dynamic SPECT projections using a spatial segmentation and temporal B-splines , 2000, IEEE Transactions on Medical Imaging.

[12]  G. Gullberg,et al.  4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior. , 2001, Physics in medicine and biology.