Nested Metamaterials for Wireless Strain Sensing

We designed, fabricated, and characterized metamaterial-based RF-microelectromechanical system (RF-MEMS) strain sensors that incorporate multiple split ring resonators (SRRs) in a compact nested architecture to measure strain telemetrically. We also showed biocompatibility of these strain sensors in an animal model. With these devices, our bioimplantable wireless metamaterial sensors are intended, to enable clinicians, to quantitatively evaluate the progression of long-bone fracture healing by monitoring the strain on the implantable fracture fixation hardware in real time. In operation, the transmission spectrum of the metamaterial sensor attached to the implantable fixture is changed when an external load is applied to the fixture, and from this change, the strain is recorded remotely. By employing telemetric characterizations, we reduced the operating frequency and enhanced the sensitivity of our novel nested SRR architecture compared to the conventional SRR structure. The nested SRR structure exhibited a higher sensitivity of 1.09 kHz/kgf operating at lower frequency compared to the classical SRR that demonstrated a sensitivity of 0.72 kHz/kgf. Using soft tissue medium, we achieved the best sensitivity level of 4.00 kHz/kgf with our nested SRR sensor. Ultimately, the laboratory characterization and in vivo biocompatibility studies support further development and characterization of a fracture healing system based on implantable nested SRR.

[1]  V. Veselago The Electrodynamics of Substances with Simultaneously Negative Values of ∊ and μ , 1968 .

[2]  W. E. Kock,et al.  Metal-Lens Antennas , 1946, Proceedings of the IRE.

[3]  David R. Smith The reality of negative refraction , 2003 .

[4]  D T Davy,et al.  Telemetric force measurements across the hip after total arthroplasty. , 1988, The Journal of bone and joint surgery. American volume.

[5]  A. Simpson,et al.  Inhibition of fracture healing. , 2007, The Journal of bone and joint surgery. British volume.

[6]  David R. Smith,et al.  Metamaterials and Negative Refractive Index , 2004, Science.

[7]  V. Shalaev Optical negative-index metamaterials , 2007 .

[8]  C. Puttlitz,et al.  Metamaterial-based wireless strain sensors , 2009 .

[9]  S M Perren,et al.  Functional load of plates in fracture fixation in vivo and its correlate in bone healing. , 2000, Injury.

[10]  V. Veselago,et al.  Электродинамика веществ с одновременно отрицательными значениями ε и μ , 1967 .

[11]  Antonius Rohlmann,et al.  Loads on an internal spinal fixation device during physical therapy. , 2002, Physical therapy.

[12]  H.V. Demir,et al.  Design and Realization of a Fully On-Chip High-$Q$ Resonator at 15 GHz on Silicon , 2008, IEEE Transactions on Electron Devices.

[13]  J Kenwright,et al.  Stiffness, strength and healing assessment in different bone fractures--a simple mathematical model. , 2000, Injury.

[14]  Ekmel Ozbay,et al.  Electrically small split ring resonator antennas , 2007 .

[15]  A Rohlmann,et al.  Monitoring In Vivo Implant Loads With a Telemeterized Internal Spinal Fixation Device , 2000, Spine.

[16]  P. Walker,et al.  Forces and moments telemetered from two distal femoral replacements during various activities. , 2001, Journal of biomechanics.

[17]  V. Podolskiy,et al.  PLASMON MODES IN METAL NANOWIRES AND LEFT-HANDED MATERIALS , 2002 .

[18]  Antonius Rohlmann,et al.  Loads on a Telemeterized Vertebral Body Replacement Measured in Two Patients , 2008, Spine.

[19]  J. Heckman,et al.  The economics of treating tibia fractures. The cost of delayed unions. , 1997, Bulletin (Hospital for Joint Diseases (New York, N.Y.)).

[20]  S. Anantha Ramakrishna,et al.  Focusing light using negative refraction , 2003 .

[21]  Christian M. Puttlitz,et al.  Bio-implantable passive on-chip RF-MEMS strain sensing resonators for orthopaedic applications , 2008 .

[22]  David R. Smith,et al.  Metamaterial Electromagnetic Cloak at Microwave Frequencies , 2006, Science.

[23]  J Kenwright,et al.  Manual assessment of fracture stiffness. , 1996, Injury.

[24]  R. Simpson,et al.  Orthopaedic Injuries Among Survivors of USS COLE Attack , 2003, Journal of orthopaedic trauma.

[25]  How to Build a Superlens , 2005, Science.

[26]  U. Chettiar,et al.  Negative index of refraction in optical metamaterials. , 2005, Optics letters.

[27]  Akhlesh Lakhtakia,et al.  Introduction to Complex Mediums for Optics and Electromagnetics , 2003 .

[28]  R. Woledge,et al.  The forces in the distal femur and the knee during walking and other activities measured by telemetry. , 1998, The Journal of arthroplasty.

[29]  D. Davy,et al.  Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[30]  D T Davy,et al.  Torsional loads in the early postoperative period following total hip replacement , 1995, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.