Field test of an old RC bridge before and after NSM strengthening

Abstract In this paper, a post-tension near-surface mounted (NSM) strengthening system is proposed to strengthen concrete structures with a relatively low amount of labor and without altering the appearance or dimensions of the structures. The main objective of this study was to investigate the structural behavior of an old reinforced concrete T (RCT) type bridge before and after using post-tension NSM strengthening systems. The 12.5 m RCT type bridge was tested using the truck loading test. The displacements of the bridge at mid-span were measured during the test. A finite element analysis model was also developed and verified with the test result. This study showed that the structural capacity and performance of the bridge were enhanced with post-tension NSM strengthening systems.

[1]  Fabio Matta,et al.  Externally post-tensioned carbon FRP bar system for deflection control , 2009 .

[2]  Dilum Fernando,et al.  FRP strengthening of 60 year old pre-stressed concrete bridge deck units , 2017 .

[3]  Carlo Poggi,et al.  End debonding of CFRP wraps and strips for the strengthening of concrete structures , 2014 .

[4]  Heeyoung Lee,et al.  Bond behavior of near surface mounted CFRP rods under temperature cycling , 2017 .

[5]  Cristina Barris,et al.  Flexural response of reinforced concrete (RC) beams strengthened with near surface mounted (NSM) fibre reinforced polymer (FRP) bars , 2014 .

[6]  Emidio Nigro,et al.  Bond Efficiency of EBR and NSM FRP Systems for Strengthening Concrete Members , 2011 .

[7]  José Sena-Cruz,et al.  Bond and flexural behavior of concrete elements strengthened with NSM CFRP laminate strips under fatigue loading , 2015 .

[8]  Björn Täljsten,et al.  Concrete Beams Strengthened with Prestressed Near Surface Mounted CFRP , 2006 .

[9]  Riadh Al-Mahaidi,et al.  Performance of RC beams rehabilitated with NSM CFRP strips using innovative high-strength self-compacting cementitious adhesive (IHSSC-CA) made with graphene oxide , 2017 .

[10]  L. Lorenzis,et al.  Near-surface mounted FRP reinforcement: An emerging technique for strengthening structures , 2007 .

[11]  Gaetano Manfredi,et al.  Behavior and Modeling of Bond of FRP Rebars to Concrete , 1997 .

[12]  Donghoon Kang,et al.  Full-scale test of a concrete box girder using FBG sensing system , 2008 .

[13]  Arnaud Castel,et al.  RC beams strengthened with NSM CFRP rods and modeling of peeling-off failure , 2010 .

[14]  Jung,et al.  Composite Strengthening of a Bridge , 2017 .

[15]  Zhishen Wu,et al.  Distributed optic fiber sensing for a full-scale PC girder strengthened with prestressed PBO sheets , 2006 .

[16]  Christoph Czaderski,et al.  40-Year-old full-scale concrete bridge girder strengthened with prestressed CFRP plates anchored using gradient method , 2007 .

[17]  I. A. Sharaky,et al.  Effect of different material and construction details on the bond behaviour of NSM FRP bars in concrete , 2013 .

[18]  C. Bakis,et al.  LOCAL BOND-SLIP RELATIONSHIP FOR FRP REINFORCEMENT IN CONCRETE , 2000 .

[19]  F. Oudah,et al.  Fatigue behavior of RC beams strengthened with prestressed NSM CFRP rods , 2012 .

[20]  Won-Seok Chung,et al.  Flexural strengthening of reinforced concrete beams with pre-stressed near surface mounted CFRP systems , 2017 .

[21]  M. Petrou,et al.  Full-Scale Experimental Investigation of Repair of Reinforced Concrete Interstate Bridge Using CFRP Materials , 2006 .

[22]  Zhishen Wu,et al.  Effects of FRP-Concrete Interface Bond Properties on the Performance of RC Beams Strengthened in Flexure with Externally Bonded FRP Sheets , 2006 .

[23]  Heeyoung Lee,et al.  Post-tension near-surface-mounted strengthening systems of full-scale PSC girders , 2017 .