Ultra-stable clock laser system development towards space applications

The increasing performance of optical lattice clocks has made them attractive for scientific applications in space and thus has pushed the development of their components including the interrogation lasers of the clock transitions towards being suitable for space, which amongst others requires making them more power efficient, radiation hardened, smaller, lighter as well as more mechanically stable. Here we present the development towards a space-compatible interrogation laser system for a strontium lattice clock constructed within the Space Optical Clock (SOC2) project where we have concentrated on mechanical rigidity and size. The laser reaches a fractional frequency instability of 7.9 × 10−16 at 300 ms averaging time. The laser system uses a single extended cavity diode laser that gives enough power for interrogating the atoms, frequency comparison by a frequency comb and diagnostics. It includes fibre link stabilisation to the atomic package and to the comb. The optics module containing the laser has dimensions 60 × 45 × 8 cm3; and the ultra-stable reference cavity used for frequency stabilisation with its vacuum system takes 30 × 30 × 30 cm3. The acceleration sensitivities in three orthogonal directions of the cavity are 3.6 × 10−10/g, 5.8 × 10−10/g and 3.1 × 10−10/g, where g ≈ 9.8 m/s2 is the standard gravitational acceleration.

[1]  J. Verbaarschot,et al.  Induced violation of time-reversal invariance in the regime of weakly overlapping resonances. , 2009, Physical review letters.

[2]  Marcin Bober,et al.  Cavity mode-width spectroscopy with widely tunable ultra narrow laser. , 2013, Optics express.

[3]  Thomas Legero,et al.  A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of 1 × 10(-15.). , 2014, The Review of scientific instruments.

[4]  Joshua R. Smith,et al.  LIGO: The laser interferometer gravitational-wave observatory , 2006, QELS 2006.

[5]  R. Holzwarth,et al.  The space optical clocks project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems , 2012, 2012 European Frequency and Time Forum.

[6]  D. Rugar,et al.  Optical clocks and relativity , 2013 .

[7]  Jennifer Michels,et al.  The Fluid Science Laboratory's Microgravity Vibration Isolation Subsystem Overview and Commissioning Update , 2010 .

[8]  Guglielmo M. Tino,et al.  The space optical clocks project , 2017, International Conference on Space Optics.

[9]  R. Spero,et al.  A flight-like optical reference cavity for GRACE follow-on laser frequency stabilization , 2011, 2011 Joint Conference of the IEEE International Frequency Control and the European Frequency and Time Forum (FCS) Proceedings.

[10]  A. Bjerhammar,et al.  On a relativistic geodesy , 1985 .

[11]  Jun Ye,et al.  Tenfold reduction of Brownian noise in optical interferometry , 2013, 1302.6489.

[12]  S. Vogt,et al.  A transportable strontium optical lattice clock , 2014, 1409.4572.

[13]  Jun Ye,et al.  Determination of Sr properties for a high-accuracy optical clock , 2008, 0807.1381.

[14]  Stephen Webster,et al.  Force-insensitive optical cavity. , 2011, Optics letters.

[15]  P. Lemonde,et al.  Ultrastable lasers based on vibration insensitive cavities , 2009, 0901.4717.

[16]  Thomas Legero,et al.  Demonstration of a transportable 1 Hz-linewidth laser , 2010, 1010.2685.

[17]  Francesco Marin,et al.  Photothermal and thermo-refractive effects in high reflectivity mirrors at room and cryogenic temperature , 2011, 1109.4491.

[18]  James C. Bergquist,et al.  Cavity-stabilized laser with acceleration sensitivity below 10-12/g-1 | NIST , 2012, 1301.0022.

[19]  S. Capozziello,et al.  Quantum tests of the Einstein Equivalence Principle with the STE–QUEST space mission , 2014, 1404.4307.

[20]  W. Gawlik,et al.  Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second , 2015, 1506.04680.

[21]  Physikalisch-Technische Bundesanstalt,et al.  Vibration-insensitive reference cavity for an ultra-narrow-linewidth laser , 2006 .

[22]  D. Holleville,et al.  Development of a strontium optical lattice clock for the SOC mission on the ISS , 2015 .

[23]  M. Wilde,et al.  Optical Atomic Clocks , 2019, 2019 URSI Asia-Pacific Radio Science Conference (AP-RASC).

[24]  F. Raab,et al.  Laser interferometer gravitational-wave observatory , 1993, Proceedings of LEOS '93.

[25]  P. Rosenbusch,et al.  Cold atom clocks and applications , 2005, physics/0502117.

[26]  Thomas Legero,et al.  8  ×  10⁻¹⁷ fractional laser frequency instability with a long room-temperature cavity. , 2015, Optics letters.

[27]  P. Rosenbusch,et al.  Interference-filter-stabilized external-cavity diode lasers , 2006 .

[28]  Thomas Legero,et al.  Tuning the thermal expansion properties of optical reference cavities with fused silica mirrors , 2010, 1002.2070.

[29]  Hidetoshi Katori,et al.  Optical lattice clocks and quantum metrology , 2011 .

[30]  Wei Zhang,et al.  Tenfold reduction of Brownian noise in high-reflectivity optical coatings , 2013, Nature Photonics.

[31]  Thomas Legero,et al.  Thermal noise in optical cavities revisited , 2011, 1111.4950.

[32]  A. Nevsky,et al.  A laboratory test of the isotropy of light propagation at the 10−17 level , 2009, CLEO/Europe - EQEC 2009 - European Conference on Lasers and Electro-Optics and the European Quantum Electronics Conference.

[33]  T. Schneider,et al.  Ultra-narrow linewidth, stable and tunable laser source for optical communication systems and spectroscopy. , 2014, Optics letters.

[34]  G Santarelli,et al.  Prototype of an ultra-stable optical cavity for space applications. , 2012, Optics express.